My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
320 74TH ST SW 2016-09-14
>
Address Records
>
74TH ST SW
>
320
>
320 74TH ST SW 2016-09-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2016 8:17:28 AM
Creation date
9/14/2016 8:17:19 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SW
Street Number
320
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pl!®L/L WORKS <br /> January 23, 2015 <br /> Rob Wickham <br /> 2812 Colby Ave <br /> Everett, WA 98201 <br /> Subject: Project: Banez <br /> Job Address: 320 74th St SW <br /> Plan Check No: C1412-015 <br /> Dear Mr. Wickham: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,) (2012 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested, along with a reduced set of plans no larger than 11"x 17". <br /> 1. Provide outside dimensions of proposed addition and existing dwelling on the site plan. <br /> 2. Provide surveyors certificate for setbacks per the City of Everett zoning code. Required <br /> when addition is located within 12"of required setback. <br /> 3. Projections that extend into the 5'-0"side yard setback are required to be protected on <br /> the underside with 1-hour fire-resistive construction. Provide detail. <br /> 4. It appears that the Simpson MST 60 called out on the upper floor plan will not work in <br /> the configuration shown. Please detail the connection to show how loads are <br /> transferred at cantilever with sliding glass door under cantilever. <br /> 5. Projections in the 5'-0"side yard setback are limited to a maximum of 18". Typical wall <br /> section shows 24" (see #3 above). <br /> 6. R-3 pipe insulation is required on all hot water piping in conditioned and non- <br /> conditioned spaces. Revise WA State Energy Code general notes. <br /> I <br /> CITY OF EVERETT• 3200 Cedar Street• Everett, WA 98201 • (425)257-8800 • Fax (425)257-8882 - <br /> S:\1Common\Clerical\]Heilman\C1412-015(320 74th St SW).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.