Laserfiche WebLink
Table 6.1 Development standards. <br /> E-1 MUO C-1 <br /> ZONE R-3 R-4 R-5 B-1 B-2 C-1R C-2 <br /> STANDARDS A-1 RS R-1 R-2 R-1A R-2A R-3L (39) (39) (39) (39) (39) B-2B B3(13) BMU (39) C-2ES(14) W-C MS M-M(14) M-1(14) M-2 <br /> Min.Lot Area 5 acres 9,000 st(1) 6,000 sf(1) 5,000 sf(1) 5,000 sf(2) 5,000 st(2) 5,000 sf 5,000 sf 5,000 sf 5,000 sf 5,000 st(15) 5,000 sf(15) 5,000 51(15) 5,000 sf(15) 5,000 sf(15) 20,000 sf 20,000 sf 5,000 sf(15) 5,000 sf(15) 5,000 sf(15) 5,000 sf(15) 1 acre(15) 5 acres(15) 1 acre(15) <br /> Min.Required 12 Strom 12 Strom <br /> Setback: curb(44) curb(44) <br /> Front(3) 25' 20' 20 20' 20' 20' 20' 20' 10' 10' None(16) None(17) 10' None(18) None(40) None(44) None(44) None(17) None(19) 10'(20) 10'(20) 20' 30' None(21) <br /> Rear(3) 25' 20' 20' 20' 20' 20' 2014) 2014) 2014) 2014) 10'(22) 10'(22) 10'(22) None None None(45) None(45) 10'(22) None(23) 10'(20) 10'(20) 20(24) 15'(26) 10'(24) <br /> Side,Street 10' 10' 10' 10' 10' 10' 10' 10' 10' 10' None(16) None(17) 10' None(18) None(40) 12 ft from 12 ft from None(17) None(19) None(20) None(20) 15' 30' None(21) <br /> (3) <br /> curb(44) curb(44) <br /> Side,Interior 10' 5' 5' 5' 5'(2) 5'(2) 515) 515) 515) 5(5) None(25) None(25) 5'(25) None None None(44) None(44) None(25) None(23) None(20) None(20) 10'(24) 15'(26) None(24) <br /> (3) <br /> Lot Width, N/A 60' 50' 50' 5012) 50'(2) 50' 50' 50' 50' 50' 50' 50' None 50' 100' 100' 50' 50' 50(20) 50'(20) 100' 150' 100' <br /> Min. <br /> Lot Depth, N/A 80' 80' 80' 80' 80' 80 80' 80' 80' 80' 80' 80' 80' 80' 100' 100' 80' 80' 80(20) 80'(20) 100' 150' 100' <br /> Min. <br /> Max Lot N/A 35% 35% 40% 40%(2) 40%(2) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 50% N/A <br /> Coverage by <br /> Building(37) <br /> Max Building 35(6) 25(7) 2817) 25(7) 2817) 2817) 35'(8) 45'(8) 8018) 8018) 28' 35'(27) 28'(27) (28) (41) 75'(46) 75'(46) 50'(27) 65'(29) 35'(20)(38) 35'(20) 65'(30) (31) 80'(32) <br /> Height <br /> Landscape E E(9) E(9) E(9) A(10) A(10) A(10) A(10) A(10) A(10) B(33) B(34) B(34) (35) B(42) 8(47) B(47) B(34) B B(20) B(20) D D(36) C <br /> Category <br /> Sign Category E(11) E(11) E(11) E(11) E(11) E(11) D(12) D(12) D(12) D(12) C A B C A(43) A(48) A(48) A B BB C C C <br /> I I <br /> SPECIAL REGULATIONS FOR ZONING CODE DEVELOPMENT STANDARDS TABLE#6.1 <br /> (1) See Section 39.130 for lot area averaging in plats and the cluster alternative for subdividing for single-family attached dwellings.In the R-2 zone,minimum lot area for single-family dwellings with alley access shall be 4,500 square feet. <br /> The minimum required lot area for a duplex in the R-2 zone shall by 7,500 square feet. <br /> (2) The following standards apply to single-family attached developments of three or more dwellings on a lot in the R-1(A)and R-2(A)zones: <br /> a) Minimum lot area in the R-1A zone shall be eleven thousand square feet.Minimum lot area in the R-2A zone shall be nine thousand square feet.There shall be no minimum lot area requirement for individual lots within a single-family <br /> attached subdivision. <br /> b) Minimum interior side setback shall be ten feet,except that it shall be fifteen feet when abutting a lot in the R-S,R-1 or R-2 zone. <br /> c) Minimum lot width shall be seventy-five feet.There shall be no minimum lot width requirement for individual lots within a single-family attached subdivision. <br /> d) All developments shall comply with Chapter 15 of this title(Multiple-family development standards)and the multiple-family design guidelines adopted by city council Resolution No.4618. <br /> e) Lot coverage requirements do not apply to single-family attached developments reviewed under the multiple-family development standards of Chapter 15 of this title and the multiple-family design guidelines. <br /> f) There shall be no minimum interior side setback requirement for individual lots within a single-family attached subdivision. <br /> (3) See Section 39.150 for exceptions to required setback standards.See Section 7.020 for setback regulations for buildings which are accessory to residential uses. <br /> (4) See Section 15.040.A.2 for exception to rear setback requirement for multiple-family dwellings. <br /> (5) Minimum setback for multiple-family dwellings shall be twenty-five feet when abutting R-S or R-1 zones,and fifteen feet when abutting R-2 zones.Building setbacks for buildings which are permitted to exceed thirty-five feet in height shall <br /> be an additional five feet for each ten feet or fraction thereof by which the building exceeds thirty-five feet in height for only those portions of the building which exceed thirty-five feet in height. <br /> (6) Agricultural structures may have a maximum building height of fifty feet. <br /> (7) See Section 7.020 for maximum permitted height of accessory buildings. <br /> (8) Twenty-eight feet for any portion of building within fifty feet of lots located in the R-S,R-1,R-2,R-1A or R-2A zones.In the R-4 and R-5 zones,forty-five feet when located at least fifty feet but less than two hundred feet from lots located <br /> in the R-S,R-1,R-2,R-1 A or R-2A zones. <br /> (9) Landscape Category E for single-family detached or two-family(duplex)dwellings.Landscape Category B for permitted nonresidential uses. <br /> (10) Landscape Category B for permitted nonresidential uses.Landscape Category E for single-family detached or two-family(duplex)dwellings. <br /> (11) Sign Category D for permitted nonresidential uses. <br />