6305 36TH AVE W B FUNKO 2016-10-27 (2)
>
Address Records
>
36TH AVE W
>
6305
>
FUNKO
>
6305 36TH AVE W B FUNKO 2016-10-27 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2016 2:00:58 PM
Creation date
9/15/2016 7:21:17 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6305
Unit
B
Tenant Name
FUNKO
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nterior Lighting Sum wy LTG-SUM <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 ov 3 stories and all R1 Revised Jan 2014 <br /> Project Info Project Address Funko T.I. Date 8/14/2015 <br /> Compliance 6301 36th Ave W For Building Department Use <br /> forms do not <br /> require a Everett,WA <br /> password to Applicant Name: S nThesis PLLC-Rand Brown <br /> use. Y Y <br /> Instructional and Applicant <br /> calculating cells Address: 12503 Bel-Red Road,Bellevue,WA 98005 <br /> are write- Applicant Phone: 425-646-1818 <br /> Project Description P� New Building ❑ Addition Alteration ❑ Plans Included <br /> © <br /> Lighting Compliance Path Lighting Power Density Calculations O Total Building Performance <br /> (If Total Building Performance then only LGT-CHK is required.) <br /> Lighting Power Allowance O Building Area Method Space-By-Space Method <br /> Method Selection required to <br /> enable LPA forms <br /> Interior Lighting System Surface mounted and recessed fluorescent fixtures in new Toilet and Break Rooms. <br /> Description <br /> Briefly describe lighting <br /> system type and features. <br /> Additions and Change of Space Use (C101.4.3 & C101.4.4) <br /> F-1 Addition area or Change of Space Use area complies with all applicable provisions as stand alone project <br /> ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable <br /> provisions per C101.4.3 <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-INT-SPACE)Compliance Form.Document maximum <br /> allowed and proposed(including existing if applicable)lighting wattage of Addition or Change of Use space.Provide applicable lighting <br /> controls per C405.2 and commissioning of lighting controls per C405.13. <br /> Alterations, Renovations and Repairs (C101.4.3.1) <br /> ❑ 60%or more of luminaires in space replaced <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-INT-SPACE)Compliance Form.Document maximum <br /> allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed(including existing)lighting wattage in <br /> Proposed Wattage table.Retrofit and non-retrofit spaces shall be documented separately using multiple forms. <br /> Less than 60%of luminaires in space replaced <br /> Provide a separate Space-By-Space Method(LTG-INT-SPACE)Compliance Form for this retrofit area. Document existing total wattage <br /> within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table.Document proposed(including existing)lighting <br /> wattage in the Proposed Wattage table. <br /> ❑ Lamp and/or ballast replacement within existing luminaires only-existing total interior building wattage not increased <br /> New wiring installed to serve added fixtures and/or fixtures relocated to new circuit <br /> Provide applicable manual lighting controls(C405.2.1),occupancy sensors(C405.2.2.2),daylight zone controls(C405.2.2.3),specific <br /> application controls(C405.2.3),and commissioning of lighting controls per C405.13 <br /> ❑ New or moved lighting panel <br /> Provide all applicable lighting controls as noted for New Wiring,automatic time switch controls(C405.2.2.1),and commissioning of lighting <br /> controls per C405.13. <br /> ❑ Space is reconfigured-luminaires unchanged or moved only <br /> Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. <br /> [::EEhanges are being made to the interior lighting and space use not changed. <br />