Laserfiche WebLink
• i <br /> Microlite° EQ <br /> Formaldehyde-free'Fiber Glass Duct Wrap Insulation <br /> Application Recommendations <br /> The R-value will vary depending upon how much the insulation is Before applying ductwrap,sheet metal duct shall be clean,dry and <br /> compressed during installation.To obtain the published installed tightly sealed at all joints and seams. <br /> R-values,the insulation stretch-out should be determined using the Wrap insulation around duct with facing to the outside so the 2"(51 mm) <br /> following table: <br /> flap completely overlaps facing and insulation atthe other end of stretch- <br /> Duct Wrap Stretch-outs out.Insulation shall be snugly butted. <br /> Installed Secure seams with outward clinching staples placed approximately <br /> Labeled Compressed 6"(152 mm)on center.If required,seal seam with pressure-sensitive <br /> Thick.(in) Thickness(in) Round Square Rectangular tape designed for use with duct insulation.Insulation on the underside of <br /> 1 0.75 P+7.0" P+6.0" P+5.0" ducts spanning 24!'(610 mm)or greater shall be secured with mechanical <br /> 1%2 1.125 P+9.5" P+8.0" P+7.0" fasteners and speed clips spaced approximately 18"(457 mm)on center. <br /> 2 1.50 P+12.0" P+10.0" P+8.0" Fasteners should be cut off flush after the speed clips are installed,and <br /> 2'A 1.75 P+13.0" P+11.0" P+8.5" when required,sealed with the same tape as specified above. <br /> 3 2.25 P+17.0" P+14.5" P+11.5" <br /> Stretch-outs include2"(51 mm)for overlap.P=perimeter of duct to be insulated Adjacent sections of duct wrap insulation shall be snugly butted with <br /> the circumferential 2"(51 mm)tape flap overlapping and secured as <br /> Prepare overlap by removing approximately 2"(51 mm)of insulation recommended for the longitudinal seam.When a vapor seal is required, <br /> from facing. two coats of vapor retarder mastic reinforced with one layer of 4" <br /> (102 mm)wide,open-weave glass fabric may be used in lieu of pressure- <br /> sensitive tape. <br /> Stretch-out <br /> Dimension Guide Specifications <br /> Insulation for Metal Ducts.All ducts shall be insulated on the outside <br /> with a Formaldehyde-free"flexible glass fiber blanket.Microlfte EQ <br /> Formaldehyde-free'fiber glass duct wrap insulation should have a <br /> minimum installed R-value*of and a Typefacing. <br /> 2.151 mm) Insulation shall be furnished with a factory-applied facing with a <br /> Overlap composite UL FHC rating of 25/50. <br /> .The minimum insulation installed R-value should be determined in accordance to <br /> the duct operating and ambient conditions. <br /> Thermal Conductivity(ASTM C518) Installed R-values <br /> V k Labeled <br /> Compressed Thickness Labeled Thickness Thickness Installed"R"** Out-of-Package"R" <br /> Type Btu•in/(heft'•°F) W/rl Btu•in/(hr•ft'•°F) W/m•*C Type in mm (heft'•°F)/Btu m'•°C/W (heft•°F)/Btu m'•°C/W <br /> 75 0.27 0.039 0.29 0.042 75 1%2 38 4.2 0.74 5.2 0.92 <br /> 100 0.25 0.036 0.27 0.039 2 51 5.6 0.99 6.9 1.22 <br /> 2%3 58 6.5 1.15 8.0 1.41 <br /> 150 0.24 0.035 0.25 0.036 3 76 8.3 #( 1.46 10.3 1.81 <br /> Conductivityat75*F(24*C)mean temperature. 100 1%2 38 4.5 0.79 5.6 0.99 <br /> *Tested with material thickness compressed 25%. 2 51 6.0 1.06 7.4 1.30 <br /> 150 1%2 38 4.7 0.83 6.0 1.06 <br /> 2 51 6.3 1.11 8.0 1.41 <br /> **Installed R-value calculated with a material thickness compressed to a <br /> maximum of 25%following recommended duct wrap stretch-outs. <br /> The physical and chemical properties of the Microlite®EQ <br /> Forma ldehyde-free"fiber glass duct wrap insulation listed herein <br /> North American Sales Offices, represent typical,average values obtained in accordance with <br /> Insulation Systems accepted test methods and are subject to normal manufacturing <br /> Eastern Region variations.They are supplied as a technical service and are subject <br /> P.O.Box 158 to change without notice.Numerical flame spread and smoke <br /> Jiu Defiance,OH 43512 developed ratings are not intended to reflect hazards presented by <br /> (800)334-2399 these or any other materials under actual fire conditions.Check with <br /> Fax:(419)784 7866 the Regional Sales Office nearest you to ensure current information. <br /> Johns Manville All Johns Manville products are sold subjectto Johns Manville's <br /> 717 17th St. Western Region and Canada standard Terms and Conditions,including Limited Warranty and <br /> P.O.Box 5108 Limitation of Remedy.For a copy of the Johns Manville standard <br /> Denver,CO 80202 Denver,CO 80217 Terms and Conditions,Limited Warranty and Limitation of Remedy, <br /> 800-654-3103 (800)368-4431 and information on other Johns Manville thermal insulation and <br /> www.JM.com Fax:(303)978-4661 systems,call(800)654-3103. <br /> HVAC-448 5/15(Replaces 11/14) ©2015 Johns Manville.All Rights Reserved. <br />