GENERAL NOTES <br />CONTRqCTORS SHALL VERIFY ALL SRE CONDITIONS AND <br />DIMENSIONS PRIOR TO COMMENCING THE WORK. <br />COMPLY W(TH THE FOLLOWING CODES: <br />20061NTERNATIONAL RESIDENTIAL CODE <br />2006 WASHINGTON STATE ENERGY CODE <br />WASHINGTON STATE VENTILATION AND INDOOR <br />QUALITY CODE (2006 EDRION� <br />OTHER APPLICABLE CODES BY JURISDICTION: <br />_ Z.00Io { BG <br />SNOW LOAD: � LBS/S.F. <br />WIND: SPEED 8S MPH <br />EXPOSURE G <br />EARTHpUAKE: S5= IZS.o� <br />S� _ <br />GENERAL STRUCTURAL NOTES <br />CONCRETE <br />1. SHALL BE FC=2500PSI � 28 DAYS. <br />2 5112 SACK MIX. <br />3. REINFORCING BARS SHALL BE ASTM A-615. <br />4. GRA�E 40 #4 RE�NFORCING. <br />FRAMING <br />7. LUMBER SHALL BE PER WYVPA STANDARDS. <br />2. L1GHT FRqMING AND STUDS HFSTUD GRADE. <br />3. STRUCTURAL JO1ST 8 PLANKS HF#2 OR BETTER <br />4. BEAMS 8 STRINGERS DF#2 OR BETTER <br />5. PO5T 3 TIMBERS DF#2 OR BETTER <br />6. GLU-LAM BEAMS: <br />-STANDARDGRADE 24F-V4 1.8E <br />-INDUSTRIALGRADE 24F•V4-IND 'I.BE <br />7. LVL 1.BE <br />8. BIG BEAMS 2.1E <br />9. IJC 26F 7.8E <br />PROVIDE 2X SOLID FIRE BLOCKING � 10 FT O.C. <br />HORIZ & VERT. �ID WALLS, STAIRS, FLRICEILS 8@ CHANGE IN CEIL <br />HEIGHT <br />ROOF TRUSSES SHALL BE DESIGNED BY LICENSED WASHINGTON <br />STATE ENGINEER. <br />SHEAR NAILING AND LATERAL BRACING SHALL BE IN <br />ACCORDANCE WI7H IRC 2006. <br />ADDITIONAL NOTES <br />1. THESE ARE PLAN ONLY DRAWINGS <br />2. CIVIL ENGIIdEERING BY OTHERS. <br />3. LANDSCAPE DESIGN BY OTHERS. <br />4. PLUMBING BY OTHERS. <br />5. HVAC DESIGN BY OTHERS. <br />6. ELECTRICAL DESIGN BY OTHERS. <br />7. INTER�OR FINISHES, CABINEf, AND HARDWARE DESIGNS <br />BY OTHERS. <br />WASHINCTON STATE ENERGY CODE <br />-�-L PRESCRIPTIVE PATH - SEE TABLE 6-'I BELOW <br />�. AL� 120 VOLT, 9b & 20 AMF RECEPTACLES INSTALLE� <br />IN BATHROOMS, WET CpUNTERTOPS�, GARAGES AND <br />OUTDOORS SHALL NAVE GFI PROTECTION. <br />2. TU8 & SHOWERS TO COMPLY WITH IRC WATER <br />RESISTANT GWB T0 70" ABOVE DRAIN. <br />3. SH04VER HEAD FLOW LIMITED TO 25 GPM. <br />4• ALL GLAZING S.G. WITNIN 70" OF DRAIN. <br />5. 15# FELT UNDER VALLEY FLASHING. <br />PROVIDE A TOTAL OF Z_O S.F. NET CRAWL SPACE VENT <br />- (UNIT �rJITMF� GQ.kkjL <br />a PnaE,, � <br />PROVIDE A TOTAL OP C1.2 S.F. NET qTTIC SPACE VENTILATION' MAi r.� <br />PROVIDE A TOTAL OF�.Sq S.F. NET ATTIC SPACE VENTILATION`V pp� <br />°(5f2 GABLE, ROOF JACKS OR RIDGE VENTS S 1@ 81RD BLOCKS OR <br />SOFFR VENT3J. <br />WASHINCTON STATE ENERGY CODE NOTES <br />GENERAL <br />1. ALL STRUCTURAL SOFTWOpD, PLYWOOD, <br />PARTICLEBOARD, WqFER BOARD AND OSB BOARD ARE <br />STAMPED WITH "EXPOSURE 1" OR "EXTERIOR". <br />2 WATER HEATER STORAGE TANN LABELED AS MEETING <br />NATL APpLIANCE ENERGY CONSERVATION ACT. ASHRAE <br />STANDAR� 9DA-1960 INSULATED TO R-16 OR R-10 IF <br />LOCATED OVER UNINSULA7ED SLAB. <br />3. IN3ULATE HOT AND COLD WqTER PIPES TO R•3 IN <br />UNHEATE➢ AREAS. <br />4. SHOWER REGULATOR TO LIMR HOT WATER DISCHARGE TO <br />2.5 GPM. <br />5� WOOQSTOVES AND FIREPLqCES HAVE TIGHT FITTING <br />DOORS, OUTSIDE COMBUSTION AIR DUCTE� TO FIREBOX <br />WITH ACCESSIBLE DAMPER. MIN. 6 SQ. IN. FREE VENT <br />ARE0. TIGHT FITTING FLUE DAMPERS REQUIRED <br />6. ALL GAS AND OIL COMBUSTON APPLIANCES HAVE A <br />DIRECT VENT OR FORCED DRAFT VENTING. <br />7: RECESSED LIGHT ARE LQ RATED, DOUBLE WALL CAN <br />UGHTS OR WITH SEALED WPGWB BOX-IN. <br />8. 6 MIL BLACK POLY VISQUEEEN IN CRAWL SPACE. <br />9. VERIFY WITN BUILDING OFFICAL THE REQUIREMENT OF A <br />RADON MONROR, INSTALLATION INSTRUCTIONS AND <br />RA�OM INFORMATION SHEETS SHALL 8E PROVIDED BY <br />THE BUILDER AT FINAL INSPECTION. <br />INSULATION - <br />1. FACED BATTS ARE LAPPED AND FACE STAPLED AT <br />FRAMING MEMBERS. <br />2. ALL EXTERIOR WALL CAVITIES ARE FILLED WITH <br />UMCOMPRESSEQ INSULATION, IHCIUDIMG AL� CAHlTIES <br />ISOIATED DURING FRAMING, WIRING, AND PLUMBING. DO <br />NOT COMPRESS INSULATION. <br />3� ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID <br />BOARD INSULATION BEMIND THEM. <br />4. 11NDERFLOOR INSULATION IS SUPPORTED 8Y LA7H, TWINE. <br />OR OTHER NON-COMPRESSED MEANS. <br />5� ATTIC ACCESS IS BAFFLED, WEATHERSTRIPPE� AND <br />INSULATED. <br />2006 WASHINGTON STATE ENERGY CODE <br />TABLE 6-i <br />PRESCRIPTIVE REQUIREMENTS°'' FOR GROUP R OCCUPANCY <br />CLIMATE ZONE 1 <br />Glazing Giazin U-Factor yya���� Walb Wall. � 6 <br />Option Area °: Doors Ceiling� Vaulted q6ove �^�� ex�" 5 Slab <br />°h of Fioor Vertical Overtiead" U-Factor Ceiling; Grade Below Below F�oor G�e <br />��' __.L <br />III. <br />IV. <br />� <br />V. <br />' Refei <br />��� <br />rHE <br />25% I 0.40 0.58 020 R38 f� R301 R-21 / R-15 R-10 R30 / � R-?0 <br />Group R-1 U=0.031 U=0.034 U-0.057 j U=0.02 i <br />antl R-2 <br />Occupanci I I I <br />Unlimfted 0.35 0.58 020 R-38 R-30 R-2? R-21 R-10 I R-30 �-1 R-10 <br />Group R-3 <br />antl R-4 i <br />Occupanci 'I � <br />es Onlv i � <br />Group R-1 <br />antl R-2 <br />U=0.031 I U=0.�34 U�0.057 R��S R-1� i U=0D2 R-10 <br />HIR SEALING <br />i. ALL P�UMBING, ELECTRICAL qN� HVAC PENETRATION IN <br />FLOOR, WALLS AND CEILINGS ARE CAULKED AND SEALED. <br />2. WHERE PENETRATIONS NEED A FIRESTOP, DISCUSS WITH <br />BUILDING OFFICIAL. <br />3. ELf:CTRICAL OUTLET AND LIGHT SWITCH BOXES ON <br />EXi'ERIOR WALL AAUST BE SEALED AT THE BACK OF THE <br />RECEPTACLE OR SEALED WITH FACE PLATE GASKEfS. <br />4. VAPOR BARRIER SHALL BE EITHER VISQUEEN OR AN <br />APPROVED VAPOR BARRIER PAINT. <br />VENTILATION <br />1. SOURCE SPECIFIC AND WHOLE HOUSE VENTILATION SYSTEMS <br />ARE REpUIRED. <br />A) SOURCE SPECIFlC EXHAUST VENTILATION IS <br />REQUIRED IN EACH KRCHEN, BATHROOM, <br />WATER CLOSET, LqUNDRY PACILRY, INDOOR <br />SWIMMING POOL, SPA AND ANY ROOM WHERE <br />EXCESS WATER VAPOR OR COOKING ODOR IS <br />PRODUCED. <br />B) WHOLE HOUSE VENTILATION RATES SHALL BE <br />DETERMINE� BY WqSHINGTON STATE VIAQ <br />2006, TABLE 3-2. <br />2. ALL VENTILATION SYSTEM CONTROLS SHALL BE <br />READILY ACCESSIBLE. <br />3� SOURCE SPECIFIC VENTILATION SYSTEMS SHA�L BE <br />CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, <br />TIMERS, OR OTMER APPROVED MEANS. <br />4. INTERMITTENT WHOLE HOUSE VENTILATION SYSTEMS <br />SHALL BE CONTROLLED BY A 24-HOL1R CLOCK TIMER, <br />WITH CAPACITY FOR CONTINUOLIS OPERATION, <br />MANUAL AND AUTOMATIC CONTROL. <br />5� WHOLE HOUSE FANS SHALL HAVE A 30NE RATING OF <br />t.5 OR LESS IF SURFACE MOUNTE� LESS THAN 4' FROM <br />CEILING. <br />6. ALL DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. <br />EXHAUST DUCTS IN SYSTEMS WHICH ARE DESIGNED <br />TO OPERATE INTERMITTENTLY SHALL BE EQUIPPED <br />WITH BACKDRAFT DAMPER. ALL EXHAUST DUCTS IN <br />UNCONDITIONED SPACE SHALL BE IN3ULATED TO A <br />MIN. R-0. <br />7- OUTDOOR AIR INLETS SHAL� BE SCREENED OR <br />OTHERWI3E PROTECTED ANO LOCATED AWAY FROM <br />POTEMIAL aR OR NOISE POLLUTION. 'i <br />R. INDIVIDUAL ROOM OUTDOOR AIR IPILETS SHALL HAVE A I <br />CONTROLLABLE AND SECURE OPENING, BE DESIGNED <br />SO AS NOT TO COMPROMISE THE THERMAL <br />PROPERTIES OF THE WALL OR WINOOW IN WMICH THEY <br />ARE PLACED, AND PROVIDE NOT LESS THAN 4 Sp. <br />INCHES OF NET FREE OPENING PER HABITABLE SPACE. <br />NON-H�AT RECOVERY VENTILATON <br />9. WH�LE HOUSE VENTILATION FAN IS CAPABLE OP EXHAUST <br />R4TE PER TABLE 3-2 <br />2- WHOLE HOUSE VENTILATION FAN SHALL BE CONTROLLED <br />BY A 24HOUR CLOCK TIMER, WITH CAPACITY FOR <br />COWTINWUS OPERATION, MANUAL AND AUTOMATIC <br />COWTROL. <br />3. THF. WHOLE HOUSE FAN HAS A SONE RATING OF c1.5 OR IS <br />REMOTELY LOCATED FROM CON�ITIONED SPACE. <br />4. ALL, EXHAUST FANS OR DUCTS HAVE TIGHT FITTING <br />BA(:KpRqFT DAMPERS. <br />5. EAC:H HABITABLE SPACE MAS A FRESH AIR SOURCE (PORT <br />OR WINDOW STYLE) OR CENTRAL DUCTED VENT <br />PRC>VI�ING NOT LESS THAN 4 SQ. INCHES OF NET FREE <br />OPENING. <br />6. AIR INTAi� SOURCES HAVE PROVISIONS FOR FLOW <br />CONTROL TO LIMIT EXCESS AIR FLOW UNOER NORMAL <br />OPERATION. <br />��- Nnndnal R-vnlu s ore For wood frame assemblies oNy or assembiies built in aceordancc with Section fi0L I. <br />+. ovlinimum requirements for isch optiou tistr,d. For exampie, if a proposed dusign has a glaang �atio to the condinoved floor <br />a� f 13 % i[ shall comply with aii of Ne ecqu'uemrnt of fhe 15 % glua� opp� (or highc). Proposed desigoF wryich canno� <br />med the specific Iequiremenis ofa listed oprion above may calculate complimce by Cbepters 4 or 5 of thia Code. <br />2. Requirem¢nt applies to all ceilings eacept single mRer orjoist vaulted ceilings complying with note3. 'Adv' dewtes <br />Advancetl Fcemed Cciiing. <br />3. Requirenwnt aop(icable onty to single iefler orjoisc vaulted ceilings wheie 6oth (e) the tlismnce between iLe top of the <br />ceiling and ihe unde�side o{the raof sheethinF lc Iess thha¢ I2 inc6es and (b) there is a mmimum 1-inch vent¢d airspace above the <br />insulatio¢ Other single rafler or jois[ vaulted cctilings shali comply wilh the "ceilio�'requuevtrnLs. 7'his option ia limited ro 500 <br />square feet of ceiling area for any one dwelling unit. <br />4. Bctnw grade we11s shall be iosuleted either m lhe ewerior to a min�um level ofR-10, m on ti�e iuterior to thc same Ievel as <br />walls aberve grede. Extmior insWetion i�mlled on below gade walls shall M: a watar msistent meteial, vmnu(aq�uM far its <br />iMended use, �and i�talled aceonding tn the rtwnufactute�'s specifi�tions. See Seetion 6022. <br />5. Fbors over c.�aw1 speces or exposed to embient av conditions. . <br />6. Requirod slab perimeter iraulstion shall be u weter resis�ant malenal. �nnfaclurcd f� its mtended use, and insmlled <br />ecro�ding to manufrcnucr's specificatia�a. Sce Section 6D2.4. <br />ro <br />7. int denaes smndeN fianting 16 inches on �mter with hcade�s msulatrd witry a minimum of R-10 msulaRan, <br />h <br />8. ]his walt i�uleGon requisment demtes R-I9 xall cevity i�sulation ptu,; R-5 Fo� Sitpthing. <br />9. ➢oors, mcluding all fiie doors, aha11 be asaigoed default U-factors from �-e6�e ]0-6C. <br />10. Where a maxi�mim glazing area is listad, thr, folal gluzing azea (combinul vertical plus merhrad) as a percart of gross <br />conditioned 11oor ama shall he Ieas than or equel w that velue. Ovenc�ad glazipg with U-fncror ofU�.40 or leu is iwt mcluded <br />m B��R � ��mitations. 1O <br />t 1- Overhead glazing shall have U-fectws determined in accordsnce wilh N}�RC 100 or as specified in Section 502.I.S. <br />12. Log and solid timbcr walls with a oilnimum nvem�e U�ickness ut3.S" arc=racempt from Ihis insulation reqw�nmri <br />Gu�.�vv�a.i� uP <br />', FWNDRp.IL <br />' 34 - 3 a'� <br />�ANG�N= O� <br />CINlSHED �LOOK <br />'LX10 rLGJ� JSTS� <br />G� l iu�� D.G, <br />FIReP..�.czaG MiD�uN �} <br />BV'f�dEEN 57uDs <br />s/sdTYPv�x� Gw�- <br />4��CONG, 6LAB <br />�LA1L, Mff�i� �LY�{TFIAT P �4'� DW+�IEi'ER- <br />GAN.lo'f Pp.ts Tt�Rdu4M. �'fYPIC�L7-� <br />030 <br />_,u,��Y, <br />�`-�n� <br />`Na' <br />�INlsNEP Ft.DofZ E ° ` <br />I - - <br />�� �O <br />� � ���$� <br />� og� <br />Ft.a�� �o�T� u I �d _ <br />� =,e pj,Ah � - <br />� a: - <br />lil " vrn3 <br />Jy < <�a <br />�� E v � <br />� o� <br />O[ �;r <br />Eo� <br />�iNraiN �'-s � s�o v <br />H�?,�20D!�1 a -„ z � <br />;i ', o.�„ <br />�I� rt£qE <br />u. I d � <br />2tl"fi�i.�fTYP.� :i i t_ �o<: v <br />I�I� __-_ <br />.2x�} hDllNtx.7iON � i E ° °' � <br />G�A�E• SILL � i - -- <br />� . - - �,.� --�k <br />- N q v <br />� 3�-O� MiFl, 'fKEA�S - sE.E F�'� Y�aN i o P"= � <br />� J o <br />F P ..�.F7�ii, O ;ad <br />O=��-�T'�._ -- -r=L-a.-\�.. . _ <br />YZ II = � i�d� <br />SIM. TD � <br />LON?- <br /><�_ {m � ��� ,_� <br />aDI� -a�-' `` ... <br />� V7 <br />��Nll � <br />�G. F2fi�• � � �. � ,� <br />�I-,�I Slri_ 70 �� � ;i <br />�---�t' � <br />1�� � � <br />F - <br />0 <br />/� �� D N,_ La G d f� A C� � ,� � <br />�' ' ,__ �... <br />=--� -� - <br />TABLE 3-2 <br />�'tiNTILATiON RATES FORl�LL GROUP R OCCUPANCIES FOUR STORIF.S ANU LESS <br />P+finimum and Maximum Veutilation Rates: Cabic Feet Per Mioute (CF�i) <br />' Floor Bedrooms <br />� Aree, ft2 2 or less 3 4 5 6 7 � g <br />blin. Max. Mia Max. Min. Maa. Min, Maz.� Min. A�Iax, Min. Max. Min. Maz <br /><500 50 75 65 98 RO 120 95 143 110 165 125 188 140 21( <br />501-1000 55 83 70 105 85 128 100 150 115 173 130 195 145 21E <br />100]-1500 60 90 75 I13 90 135 705 158 120 180 135 203 150 225 <br />, 1501-2000 65 98 80 120 95 l43 110 165 125 188 140 210 155 233 <br />'i Z001-3500 70 ]OS 85 128 100 150 I15 173 130 195 145 318I 160 240 <br />2501-3000 75 ll3 90 135 105 158 120 180 135 203 150 225 165 248 <br />� 3001-3500 80 120 95 143 I10 165 125 188 140 210 155 233 170 255 <br />3501-4000 85 128 100 I50 Il5 ]?3 130 19>i 145 218 160 240 175 263 <br />! 4001-5000 95 143 110 165 1Z5 188 740 210 155 233 1?0 255� 185 27S <br />I 5001-6000 ]OS 158 120 180 13s 203 150 ;25 165 246 180 270 195 293 <br />6001-7000 ll5 173 730 195 145 27R 160 240 175 263 190 285 205 308 <br />7001-SOUO 135 188 140 210 155 233 170 255 185 278 200 300 215 323 <br />8007-9000 135 203 I50 225 165 248 180 270 195 293 210 315 225 338 <br />>9000 145 2I8 I60 24U 175 263 190 285 205 306 220 330 235 353 <br />"For reside:nces th3t exceed S 6edrooms, increase the minimum requirement ]isted for 8 bedrooms by an additional <br />15 CFM ner bedroom. The mvcimum CFM is equai to 1 S times [he tninimum. <br />