Laserfiche WebLink
Component Perforrr� �ice Path, pg. 1 Zo :s 4c/5b ENV-UA <br />2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Oct 2013 <br />ProjectAddress Everett r�ii Date 03/03/2015 <br />Occupancy Group � Commercial 0 Group R For Building Department Use <br />Change in occupancy or space conditioning 0 <br />Note - Proposed UA may exceed Target UA by 10% per C101.4.4 and C101.4.5 <br />Fenestration Area as °/o gross above-grade wall area Max. Target: 30 . 0� <br />Skylight Area aS % gross roof area Max. Target: 5. 0� <br />Vertical Fenestration Alternates: None Selected on ENV-SUM <br />Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope <br />elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br />2: U-factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2. <br />Building Component Proposed UA Target UA <br />Provide source of U-factor, pa e/ lan # of assembl detail & ID U-factor x Area (A) = UA (U x A U-factor x Area (A) = UA (U x A) <br />R= ID: 0.034 <br />Y <br />a�i R= ID: Above Deck Insuiation U-0.034 <br />0 <br />R= ID: <br />� -o R= ID: EXISTING o.031 <br />o m R= ID: Metal Building U-0.031 <br />� � R= ID: <br />` R= ID: 0.021 <br />� R= ID: Single raft, attic, other U-0.021 <br />� R= ID: <br />� R= ID: EXISTING 0.055 <br />� R= ID: Steel/metal frame U-0.055 <br />a� <br />� R= ID: <br />o-a R= ID: EXISTING 0.052 <br />¢ 00 R= ID: Metal Building U-0.052 <br />N � R= ID: <br />� � R= ID: EXISTING 0. 054 <br />� o R= ID: Wood Frame, other U-0.054 <br />� o <br />a � R= ID: <br />O <br />. R= ID: EXISTING 0.104 <br />N <br />� R= ID: Mass Wall U-0.104 <br />� R= ID: <br />N R= ID: 0.104 <br />m <br />o� R= ID: Assumed to be Mass Wall U-0.104 <br />a� � <br />m � R= ID: <br />c� R= ID: <br />N R= ID: EXISTING 0. o3i <br />m R= ID: Mass Floor U-0.031 <br />a � R= ID: <br />� � R= ID: EXISTING 0.029 <br />� <br />� R= ID: JoisUFraming U-0.029 <br />� R= I D: <br />F-factor x Perimeter = UA(U x A) F-factor x Perimeter = UA (U x A) <br />� R= ID: EXISTING 0.540 <br />� L R= ID: Slab-On-Grade U-0.54 <br />� � R= ID: <br />� � R= ID: 0.550 <br />�� R= ID: Heated Slab-On-Grade U-0.55 <br />= R= ID: <br />`Proposed non-residential CMU walls meeting Table C402.1.2 Area UA Area UA <br />Footnote D requirements can use the target U-value of 0.104 rather Page 1 <br />than Appendix A values. Show footnote requirements in plans. Subtotal <br />Component Performance Compliance (UA) <br />