|
�
<br />�1� n �� �� �� I I
<br />A __ -
<br />�. � � � � — .r �
<br />�
<br />STEEL CHANNEL FOR CANOPY FASCIA (EXISTING)
<br />�,
<br />B
<br />0
<br />�_,11 � n n�� (� (��1 i �--
<br />�—�
<br />NOTE:1" SPACE REQUIRED BETWEEN TOP OF BENT METAL PLATE AND BOTTOM OF CHANNEL LETTER :�
<br />QINDIVIDUAL INTERNALLY ILLUMINATED CHANNEL LETTER LAYOUT
<br />�
<br />TYPE A B SQ.FL QTY
<br />C-BWW24RW 2'-0" 28'-0" 56.0 1
<br />CHANNEL LETTERS "BWW":
<br />RETURNS: 5" DEEP, PRE-FINISHED BLACK ALUMINUM LETTERS PAINTED BLACK ON ALL EXTERIOR SURFACES
<br />FACES: #7328 WHITE ACRYLIC BANDED W/A 1" BLACK TRIM CAP.
<br />ILLUMINATION: VIA SLOAN VL PLUS-2 WHITE LEDS
<br />❑ #7328 � WHITE ACRYLIC (Translucent)
<br />WHITE
<br />� RETURNS � TRIM-CAP
<br />BLACK
<br />FEDERAL
<br />N EATH
<br />SIGN COMPANY
<br />www.FederalHeath.com
<br />1128 Beville Road, Suite E
<br />Daytona Beach, FL 32114
<br />(386� 255-f901 Fax (386) 258-0211
<br />Total: T.B.D. Amps
<br /># of 120V, 20A Circuits Req'd T.B.D.
<br />ALL BRANCH CIRCUITS SHALL BE
<br />DEDICATED TO SIGNS (INCLUDING
<br />GROUND AND NEUTRAL) AND SHALL
<br />NOT BE SHARED WITH OTHER LOADS.
<br />Aluminum Letter Returns-
<br />with White Interior Finish
<br />Trim Cap Retainer
<br />Sloan UL Plus-2 White LED Modules
<br />063 Aluminum Letter Backs
<br />with White Interior Finish
<br />3,16" Acrylic Faces
<br />120v/12vdc Power Supply Located Inside
<br />E�Rruded Aluminum Raceway-
<br />External Cut Off Switch Required
<br />Raceway/Letters Mounted 1" Off j"
<br />Cont. Bent Platefor Draina9e Purposes�
<br />Standard Raceway ptd ';G" DrainHole
<br />To Match SW 7069 "Iron Ore"
<br />(Unless Otherwise Specified
<br />Due to existing building conditions)
<br />Yn" CONT BENT PL �
<br />THUS: �
<br />� 18'
<br />3°
<br />p� p� NOTE: IN LOCATIONS WHERE
<br />SOME OR ALL OF THE BACKS
<br />OF THE LETTERS ARE VISIBLE
<br />THEY SHOULD BE PAINTED
<br />BLACK AND INCORPORATE
<br />FABRICATION TECHNI�UES
<br />THAT HIDE OR ELIMINATE
<br />VISIBLE NOTCHING Of LETTER
<br />RETURNS AND MINIMIZE
<br />EXPOSED FASTENERS.
<br />� L6x4x�/6 CONT AT SIGNAGE ;
<br />i LOCATION ONLY, SEE ARCH '
<br />� r i FOR EXTENTS (INTERRUPT AT i
<br />i I ; BEAM LOCATIONS) �
<br />T� �, I(NOTE: PROVIDED & INSTALLED BY GC) ;
<br />�� � I�'' i — �---------- ---'
<br />!8" dia. S/S moun'ng hardware i2�� Dia. Sealtite for
<br />----- -- ---- ----- Primary Connection
<br />\ � ROOF DECK
<br />�
<br />_ n� kx� �f B� sP�c��G
<br />COLUMN
<br />SECTION DETAIL -CANOPY MOUNTED CHANNEL LETTERS ON RACEWAY
<br />CUSTOMER TO PROVIDE:
<br />(For New / Remodel Construction) ADE�UATE BEHIND THE WALL BACKING AND ACCESS A5 REQUIRED TO INSTALL
<br />SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT
<br />SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION.
<br />ALL BRANCH(PRIMARY ELECTRICAL SERVICE) CIRC6IE FINAL CONNECTION TO EACH SI(�WITHIN 5 Ff.jfO BE BY CERTIFIE� ELECTRICIAN:
<br />A. All hranch circuits for signs must he totally dedicated to signs (including dedicatetl ground and dedicated neutral per circuR).
<br />B. Sign circufts must not be shared with other loads such as lighting, air conditioning, and other equipmerR.
<br />C. Proper�y s¢ed ground wire that can be traced hack to the 6reaker panel must be provided.
<br />D. Num6er and size of circuits for each sign to meet Federal Heath Sign's requirement.
<br />Any tleviation from the above recommendations may result in:
<br />1. Damage to or improper operatlon of the sign(s).
<br />2. Delays and additional costs.
<br />Notes: - Certain electncal components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best pertormance,
<br />we recommentl signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that
<br />will automaUcalty shut-off the sign for a penotl of time, each day. Failure to do so will cause damage to the elecfical components of the sign and
<br />will void the warranty.
<br />_ Some dimming devices will also adversely affect sign elecficai components, causing failure. Any tlimming of the sign without consuttation
<br />with Federal Heath Sign Co. will void the warranty.
<br />INSTALLERIS RESPONSIBLEFOR:
<br />PROVIDING AND INSTALLING ALL COMPONENTS REDUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT,
<br />ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS.
<br />ELECTRICAL NOTES:
<br />1. INSTALLATIdN OF THESE (ELECTRICAL) SIGNS SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF THE
<br />N.E.C., U.L. 48 ANQ / OR OTHER APPLICABLE LOCAL CODES.
<br />THIS INCLUDES PROPER GROUNDING AN� BON�ING OF THE SIGN.
<br />PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS.
<br />SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS..
<br />_ ; � s_r�+�, � �-�x� . _ �, .� . �, ; - __ �_�_ �_� ����,-�_ � � �� � sl v-. _
<br />Revisions:
<br />Ma,,,,r�rn,�„9 F���mes: Account Rep: RANDY CEARLOCK
<br />OCNnS10e.CA-EuIeSS.iX-Jatl6onNI1e.TX-ONaware.OH �. �.1'i.;: ' - I I,,;��.i;l!;'�1�.
<br />� «aauo� Project Manager: TOM DEFILIPPO
<br />0.�cansiae. Ca - Las Vegas. NV - Laughlin, AZ - IOaho FaiB. ID
<br />e�i�,nc-�a�o�wn�,nc-s���.,�a,�o,rx-co�v�rn�,.nc Drawney: VIRGOARAGONES/JULIEREILLY
<br />InEiarepolis, IN - Delaware, OH - I(nonville TN - Louimlle. KY
<br />Gafton, WI- Wllowbrook, IL-Tunica, M1LS Co�ors �:o�:c'e� Ir, ihis Rendenr,g May Not Malch Ac.ual Finilhed Mate�ials. Refer To °roCuc: �an'oi'c Fo� Exac: Co:or Ma:cn u���me� f pp(�ryW, 7p USF U.L USIEo
<br />Atlana,GA-Tampa,FL-Day[onaBeach.FL- Orlarrdo,Fl. U f1EC ^LMPONINfSAND^SNALL RDES
<br />Client Approval/Date: • � Labcretories Inc. 4
<br />I�LL ELECTRICAL SIGNS AFF TO COMPLY WITM U.L. 48 ANU
<br />Bullding Quality Signage Since 1901 Landlord ApprovaVDate: �w*�<<E d�� �F *�E N.E.C. STANDARDS, INCLf1UING
<br />THE PROPER GROUNDING 11ND BONDING OF ALL SIGNS.
<br />Project / Location:
<br />�
<br />1402 SE EVERETT MALL
<br />WY SPACE 415
<br />EVERETT, WA 98208
<br />This original drawing
<br />,ob N�mbe�: 23-26153-10 is provided as part of a
<br />planned projecc
<br />Januar 21 2015 and is not to be exhibited,
<br />Date: y , copied or reproduced
<br />without the written
<br />Shee[ Number: �F Of J p e r m i s s i o n o f
<br />Federai Heath Sign
<br />Company, LLC or ics
<br />oes�9�"�mbe�: 23-26153-10 R1 aumo��zea zge�t �,FHs�
<br />
|