Laserfiche WebLink
� <br />�1� n �� �� �� I I <br />A __ - <br />�. � � � � — .r � <br />� <br />STEEL CHANNEL FOR CANOPY FASCIA (EXISTING) <br />�, <br />B <br />0 <br />�_,11 � n n�� (� (��1 i �-- <br />�—� <br />NOTE:1" SPACE REQUIRED BETWEEN TOP OF BENT METAL PLATE AND BOTTOM OF CHANNEL LETTER :� <br />QINDIVIDUAL INTERNALLY ILLUMINATED CHANNEL LETTER LAYOUT <br />� <br />TYPE A B SQ.FL QTY <br />C-BWW24RW 2'-0" 28'-0" 56.0 1 <br />CHANNEL LETTERS "BWW": <br />RETURNS: 5" DEEP, PRE-FINISHED BLACK ALUMINUM LETTERS PAINTED BLACK ON ALL EXTERIOR SURFACES <br />FACES: #7328 WHITE ACRYLIC BANDED W/A 1" BLACK TRIM CAP. <br />ILLUMINATION: VIA SLOAN VL PLUS-2 WHITE LEDS <br />❑ #7328 � WHITE ACRYLIC (Translucent) <br />WHITE <br />� RETURNS � TRIM-CAP <br />BLACK <br />FEDERAL <br />N EATH <br />SIGN COMPANY <br />www.FederalHeath.com <br />1128 Beville Road, Suite E <br />Daytona Beach, FL 32114 <br />(386� 255-f901 Fax (386) 258-0211 <br />Total: T.B.D. Amps <br /># of 120V, 20A Circuits Req'd T.B.D. <br />ALL BRANCH CIRCUITS SHALL BE <br />DEDICATED TO SIGNS (INCLUDING <br />GROUND AND NEUTRAL) AND SHALL <br />NOT BE SHARED WITH OTHER LOADS. <br />Aluminum Letter Returns- <br />with White Interior Finish <br />Trim Cap Retainer <br />Sloan UL Plus-2 White LED Modules <br />063 Aluminum Letter Backs <br />with White Interior Finish <br />3,16" Acrylic Faces <br />120v/12vdc Power Supply Located Inside <br />E�Rruded Aluminum Raceway- <br />External Cut Off Switch Required <br />Raceway/Letters Mounted 1" Off j" <br />Cont. Bent Platefor Draina9e Purposes� <br />Standard Raceway ptd ';G" DrainHole <br />To Match SW 7069 "Iron Ore" <br />(Unless Otherwise Specified <br />Due to existing building conditions) <br />Yn" CONT BENT PL � <br />THUS: � <br />� 18' <br />3° <br />p� p� NOTE: IN LOCATIONS WHERE <br />SOME OR ALL OF THE BACKS <br />OF THE LETTERS ARE VISIBLE <br />THEY SHOULD BE PAINTED <br />BLACK AND INCORPORATE <br />FABRICATION TECHNI�UES <br />THAT HIDE OR ELIMINATE <br />VISIBLE NOTCHING Of LETTER <br />RETURNS AND MINIMIZE <br />EXPOSED FASTENERS. <br />� L6x4x�/6 CONT AT SIGNAGE ; <br />i LOCATION ONLY, SEE ARCH ' <br />� r i FOR EXTENTS (INTERRUPT AT i <br />i I ; BEAM LOCATIONS) � <br />T� �, I(NOTE: PROVIDED & INSTALLED BY GC) ; <br />�� � I�'' i — �---------- ---' <br />!8" dia. S/S moun'ng hardware i2�� Dia. Sealtite for <br />----- -- ---- ----- Primary Connection <br />\ � ROOF DECK <br />� <br />_ n� kx� �f B� sP�c��G <br />COLUMN <br />SECTION DETAIL -CANOPY MOUNTED CHANNEL LETTERS ON RACEWAY <br />CUSTOMER TO PROVIDE: <br />(For New / Remodel Construction) ADE�UATE BEHIND THE WALL BACKING AND ACCESS A5 REQUIRED TO INSTALL <br />SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT <br />SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. <br />ALL BRANCH(PRIMARY ELECTRICAL SERVICE) CIRC6IE FINAL CONNECTION TO EACH SI(�WITHIN 5 Ff.jfO BE BY CERTIFIE� ELECTRICIAN: <br />A. All hranch circuits for signs must he totally dedicated to signs (including dedicatetl ground and dedicated neutral per circuR). <br />B. Sign circufts must not be shared with other loads such as lighting, air conditioning, and other equipmerR. <br />C. Proper�y s¢ed ground wire that can be traced hack to the 6reaker panel must be provided. <br />D. Num6er and size of circuits for each sign to meet Federal Heath Sign's requirement. <br />Any tleviation from the above recommendations may result in: <br />1. Damage to or improper operatlon of the sign(s). <br />2. Delays and additional costs. <br />Notes: - Certain electncal components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best pertormance, <br />we recommentl signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that <br />will automaUcalty shut-off the sign for a penotl of time, each day. Failure to do so will cause damage to the elecfical components of the sign and <br />will void the warranty. <br />_ Some dimming devices will also adversely affect sign elecficai components, causing failure. Any tlimming of the sign without consuttation <br />with Federal Heath Sign Co. will void the warranty. <br />INSTALLERIS RESPONSIBLEFOR: <br />PROVIDING AND INSTALLING ALL COMPONENTS REDUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, <br />ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. <br />ELECTRICAL NOTES: <br />1. INSTALLATIdN OF THESE (ELECTRICAL) SIGNS SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF THE <br />N.E.C., U.L. 48 ANQ / OR OTHER APPLICABLE LOCAL CODES. <br />THIS INCLUDES PROPER GROUNDING AN� BON�ING OF THE SIGN. <br />PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. <br />SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS.. <br />_ ; � s_r�+�, � �-�x� . _ �, .� . �, ; - __ �_�_ �_� ����,-�_ � � �� � sl v-. _ <br />Revisions: <br />Ma,,,,r�rn,�„9 F���mes: Account Rep: RANDY CEARLOCK <br />OCNnS10e.CA-EuIeSS.iX-Jatl6onNI1e.TX-ONaware.OH �. �.1'i.;: ' - I I,,;��.i;l!;'�1�. <br />� «aauo� Project Manager: TOM DEFILIPPO <br />0.�cansiae. Ca - Las Vegas. NV - Laughlin, AZ - IOaho FaiB. ID <br />e�i�,nc-�a�o�wn�,nc-s���.,�a,�o,rx-co�v�rn�,.nc Drawney: VIRGOARAGONES/JULIEREILLY <br />InEiarepolis, IN - Delaware, OH - I(nonville TN - Louimlle. KY <br />Gafton, WI- Wllowbrook, IL-Tunica, M1LS Co�ors �:o�:c'e� Ir, ihis Rendenr,g May Not Malch Ac.ual Finilhed Mate�ials. Refer To °roCuc: �an'oi'c Fo� Exac: Co:or Ma:cn u���me� f pp(�ryW, 7p USF U.L USIEo <br />Atlana,GA-Tampa,FL-Day[onaBeach.FL- Orlarrdo,Fl. U f1EC ^LMPONINfSAND^SNALL RDES <br />Client Approval/Date: • � Labcretories Inc. 4 <br />I�LL ELECTRICAL SIGNS AFF TO COMPLY WITM U.L. 48 ANU <br />Bullding Quality Signage Since 1901 Landlord ApprovaVDate: �w*�<<E d�� �F *�E N.E.C. STANDARDS, INCLf1UING <br />THE PROPER GROUNDING 11ND BONDING OF ALL SIGNS. <br />Project / Location: <br />� <br />1402 SE EVERETT MALL <br />WY SPACE 415 <br />EVERETT, WA 98208 <br />This original drawing <br />,ob N�mbe�: 23-26153-10 is provided as part of a <br />planned projecc <br />Januar 21 2015 and is not to be exhibited, <br />Date: y , copied or reproduced <br />without the written <br />Shee[ Number: �F Of J p e r m i s s i o n o f <br />Federai Heath Sign <br />Company, LLC or ics <br />oes�9�"�mbe�: 23-26153-10 R1 aumo��zea zge�t �,FHs� <br />