My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3617 GEYER LN 2016-09-28
>
Address Records
>
GEYER LN
>
3617
>
3617 GEYER LN 2016-09-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2016 1:36:51 PM
Creation date
9/28/2016 1:36:35 PM
Metadata
Fields
Template:
Address Document
Street Name
GEYER LN
Street Number
3617
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PURL/C WORKS <br /> y <br /> March 9, 2015 <br /> Steve Waisanen <br /> Subject: Project: Pachl <br /> Job Address: 3617 Geyer Ln <br /> Plan Check No: CW1502-002 <br /> Dear Mr. Waisanen: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,) (2012 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested, along with a reduced set of plans no larger than 11"x 17". <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> 1. Provide retaining wall designed by licensed structural engineer for CMU walls with pony <br /> walls on top. Provide detail(s) for each condition, joists parallel, joists perpendicular and <br /> no joists (at stairs) attached at top of wall. <br /> 2. Provide 2x6 wall with R-21 insulation between the basement and the unheated storage <br /> room, with exterior door. <br /> 3. Provide minimum 100 CFM fan in kitchen, vent to exterior. <br /> 4. The window well shall be minimum 9 square feet horizontal area with a minimum <br /> horizontal projection and width of 36 inches. <br /> 5. Provide natural light per section R303 International Residential Code (IRC) in the family <br /> room. If artificial light is to be used to meet the requirement provide the lighting <br /> schedule. <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> S:\1Common\Clerical\]Heilman\CW1502-002(3617 Geyer Ln).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.