Laserfiche WebLink
2012 Washington State En Code Compliance Forms for Commercial, Gro R1, and > 3 story R2 and R3 <br /> 2012 Washington State Energy Code Com fiance Forms for Commercial, Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Info Project Address 2715 Hewitt Avenue Date 1/3/2014 <br /> Everett, WA 98201 For Building Dept. Use <br /> Applicant Name: Sound Mechanical Solutions , <br /> Applicant Address: 7805 Skipley Road Snohomish, WA 98290 <br /> Applicant Phone: 425-210-7522 <br /> Project Description Provide one new 6 ton and one new 3 ton gas fired packaged rooftop HVAC units with <br /> Briefly describe mechanical ductwork and gas piping to support tenant improvements. Provide one new restroom <br /> system type and features. exhaust fan and one new oven ventilation fan. <br /> n Includes Plans Drawings must contain notes requiring compliance with commissioning provisions per Section C408 <br /> I <br /> CO Simple System ( Complex System O Systems Analysis <br /> Compliance Opinion <br /> The following information is required to be incorporated with the mechanical equipment schedules on <br /> Equipment Schedules the plans. For projects without plans,fill in the required information below. <br /> Cooling Equipment Schedule <br /> Equip. Equip Capacity2 OSA CFM SEER Econmizer Heat <br /> ID Type Brand Name' Model No.' Btu/h or Econo? or EER IPLV3 Option or Recovery <br /> Exce tion6 Y/N <br /> RTU-1 Rooftop Trane YSC060 75000 Econo 11 Econo N <br /> RTU-2 Rooftop Trane YSCO36 35600 Econo 13 Econo N <br /> Heating Equipment Schedule <br /> Equip, Equip Capacity2 OSA cfm Heat <br /> ID Type Brand Name' Model No.' Btu/h or Econo? Input Btuh Output Btuh Efficiency4 Recovery <br /> Y/N <br /> RTU-1 Rooftop Trane YSCO60 96000 Econo 120000 96000 80 N <br /> RTU-2 Rooftop Trane YSC036 48000 Econo 60000 48000 80 N <br /> Fan E ui ment Schedule <br /> Equip. Equip <br /> ID Type Brand Name' Model No.' CFM SP' HP/BHP Flow Control' Location of Service <br /> EF-1 Ceiling Broan QTR 60 80 0.10 0.7A CV Restroom <br /> EF-2 Rooftop DU12HFA 400 0.50 0.18 hp Cv Oven vent <br /> i <br /> I <br /> Service Water Heating Equi ment Schedule <br /> Equip. Equip Input Sub- <br /> ID Type Brand Name' Model No.' Capacity Category EF' Location of Service <br /> If available. z As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP.. HSPF,Combustion Efficiency,or AFUE,as <br /> applicable. 5 Flow control types:variable air volume(VAV),constant volume(CV),or variable speed(VS). 6 Economizer exception number per <br /> I /U <br />