Laserfiche WebLink
2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Address 2715 Hewitt Avenue Date 1/3/2014 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. N9.TE:Define r' area in Excel Prior to printingMECH-CHK pages. <br /> Applicability Location on Building Department <br /> (yes,no,na) Code Section Code Provision Information Required Plans Notes <br /> GENERAL PROVISIONS,CONTINUED <br /> HVAC System Controls&Criteria,Continued <br /> C403.2.12 Variable flow control- indicate fan&pump motors requiring VF control&method(VSD or equiv <br /> na fans! um s controls <br /> C403.2.12.1 Variable flow control- Indicate cooling tower fans requiring variable flow control and method <br /> na cooling!Owers <br /> C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooing <br /> na demand;or exception taken <br /> C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys.>110,000 btuh <br /> na <br /> na C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for <br /> Ducting Systems <br /> C403.2.7.1& Duct construction Indicate all ductwork constructed and sealed per IMC,C402 leakage <br /> Yes C403.2.7.3 requirements and IBC vapor retarder requirements M-1 <br /> yes C403.2.7.3.14 Duct pressure classifications Identify location of low,medium and high pressure ductwork on plans M_ <br /> C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide <br /> na test test results to jurisdiction when completed <br /> Yes C403.2.7.1/2 Duct insulation Indicate R-value of insulation on ductwork M_1 <br /> Piping Systems <br /> na C403.2.8 Piping insulation Indicate R-value of insulation on piping <br /> na C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage/depredation <br /> weather <br /> SIMPLE SYSTEMS <br /> Qual Eying Systems <br /> e5 C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits,does M-1 <br /> Y systems not have active humidifcation or simultaneous heating/cooling <br /> C403.3 Qualifying 2-pipe heating Verify 2-pipe heating-only system does not exceed capacity limits <br /> na systems <br /> na C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 <br /> Simple System Economizers <br /> Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip sched. M-1 <br /> yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100%OSA,or exception M-1 <br /> yes C403.3.1.1.3 Air a <br /> controls omizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M <br /> C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with M-1 <br /> Yes oeratlon Icaparity>65,000 btuh <br /> na C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with <br /> COMPLEX SYSTEMS <br /> Complex System Economizers <br /> C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip sched. <br /> 9C403.4.1.4Economizer heating system Verify control method of HVAC systems with economizers does not increase <br /> impact building heating energy usage during normal operation <br /> Integrated economizer Indicate capability for partial economizer operation for air or water econos tems <br /> Water economizer capacity Indicate water econo capable of 100%cooling capacity at 50°F db/45°F wb <br /> OSA <br /> C403.4.1.2 Water economizer maximum Indicate precooling coils and heat exchangers do not exceed pressure drop <br /> pressure drop limit <br /> C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with <br /> �f <br /> i <br />