My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2517 HOWARD AVE SPRINT ANTENNA 2018-11-27
>
Address Records
>
HOWARD AVE
>
2517
>
SPRINT ANTENNA
>
2517 HOWARD AVE SPRINT ANTENNA 2018-11-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2018 9:12:25 AM
Creation date
9/29/2016 10:13:34 AM
Metadata
Fields
Template:
Address Document
Street Name
HOWARD AVE
Street Number
2517
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/4 Sprint <br /> o,9 <br /> 0,Ln N:Z <br /> w rn O,.Z N Lf) <br /> 1m N 3-5 NEW SPRINT 190OMHI 00 <br /> N G"9 A-6 RRU (1 PER SECTOR) =I;u ✓'m <br /> Y REPLACE EXISTING CDMA <br /> = fn A�8 1900MHHzz NV ANTENNAMOUNTED� e GENERAL DYNAMICS <br /> t3'-10" ON NEW PIPE WIRELESS SERVICES <br /> t3'-10" <br /> 3-5 NEW SPRINT 1900MHz <br /> A-6 RRU (1 PER SECTOR) <br /> EXISTING VACANT <br /> PIPE MOUNT, TYP. <br /> ENGINEERING <br /> EXISTING CHIMNEY EXISTING CHIMNEY c PROJECT INFORMATION: <br /> ON ROOF TOP ON ROOF TOP <br /> REPLACE EXISTING CDMA <br /> MO M (72o SFCj 2 ANTENNA WITH NEW SPRINT NETWORK VISION MM0.SLAUNCH <br /> UIVj/ OR A-B 1900MHz NV ANTENNA MOUNTEI <br /> (110 q2/MUrHH �fG1 9I/M�jy ON NEW PIPE BROADWAY <br /> °�o�J��l e��� o• `(�oSe�T�R �dG��\�J��o`'G <br /> SE63XC209 <br /> EXISTING SPRINT PANEL ANTENNA <br /> AlTO BE REMOVED FOR FINAL 2517 HOWARD AVE <br /> I `�y OJ P T HJ nU0 �(/N7j CONFIGURATION.TYP. OF 2 PER EVERETT, WA 98203 <br /> �L �'S° �4 L�' R`J• <br /> (170. ASG+p SECTOR <br /> L Ixs `, '924N 1N <br /> SNOHOMISH COUNTY <br /> EXISTING rCj O• UT/'(j 1 6S, <br /> EXISTING SPRINT MUE m—mc TOWERWE <br /> ANTENNA <br /> f <br /> PANEL ANTENNA TY'P, NORTH NORTH 5�G V�,LI (1 $fCr y ISSUE DATE 07-30-12 <br /> OF 2 PER SECTOR LAAO pal. 10• /�� , NORTH NORTH <br /> EXISTING <br /> ANTENNA � � ISSUED FOR ZONING/PERMITTING <br /> TOWER 2 REPLACE EXISTING CDMA 3-5 NEW SPRINT 190OMHz <br /> ANTENNA WITH NEW SPRINT A-6 RRU (1 PER SECTOR) <br /> A-8 <br /> 190 MHz W ANTENNA MOUNTED REVISIONS <br /> ON NEW PIPE REV. DATE DESCRIPTION INITIALS <br /> A 7/30/12 90% CD's J.F. <br /> 1 x34•SCALE: NOT TO SCALE EXISTING ANTENNA PLAN 1 11 <br /> x34•SCALE: NOT TO SCALE NEW ANTENNA TEMP.PLAN(INTERIM) 12 O 09/12/12 ,00x DD's RLS <br /> 11 <br /> 11'x17'SCALE NOT TO SCALE 11•x17'SCALE: NOT TO SCALE <br /> S <br /> STRUCTURAL ANALYSIS MUSE BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRUS, & NEW CABINETS/TEMPORARY <br /> PLATFORM.STRUCTURAL ANALYSIS TO BE PROVIDED BY GENERAL DYNAMICS. <br /> D N O;y HIX14TING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE <br /> N m <br /> Z NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA SIMILAR TO THAT SHOWN ON DETAIL 1,SHEET A-6. <br /> 3-5 EXISTING VACANT NEW SPRINT 1900MHz C O N O <br /> A-6 RRU (1 PER SECTOR) vial �'"0 _ FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS. <br /> ID =Z PIPE MOUNT,TP. � . <br /> eREPLACE EXISTING CDMA I ✓fTi ALL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAD CENTER AND ORIENTATIONS WITH SPRINT PCS <br /> ANTENNA WITH NEW SPRINT 'i PRIOR TO INSTALLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED <br /> A-8 190OMHz NV ANTENNA MOUNTED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO TOWER <br /> ON NEW PIPE STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. <br /> :37,10" <br /> 3-5 NEW SPRINT 190OMHz RRU / HYBRID CABLE SCHEDULE <br /> A-6 RRU (1 PER SECTOR) SECTOR RRU MODEL RRU FREQUENCY HYBRID CABLE HYBRID CABLE JUMPER JUMPER RET RET CABLE RET CABLE <br /> LENGTH DIAMETER SIZE LENGTH LENGTH MANUFACTURER MODEL NUMBER NOT FOR CONSTRUCTION UNLESS <br /> ALPHA RRH-P4 (1)1900MHz 75' N/A 1 1/2• 6' 9.8' COMMSCOPE ,RET AISGV2.0 LABELED AS CONSTRUCTION SET <br /> BETA RRH-P4 (1)1900MHz 75' N/A 1/2• 6' 1 9.8' COMMSCOPE I,RET AISGv2.0 <br /> GAMMA RRH-P4 (1)1900MHz 75' N/A 1/2' 6' 9.8' COMMSCOPE RET AISGv2.0 LICENSURE <br /> EXISTING CHIMNEY 1900 EQUIPMENT ONLY <br /> ON ROOF TOP <br /> N REPLACE EXISTING CDMA ANTENNA SCHEDULE <br /> 2 ANTENNA WITH NEW SPRINT SECTOR ANTENNA ANTENNA ANTENNA ANTENNA AZIMUTH RAD CENTER ANT. SIZE ELECT TILT MECH TILT <br /> �O FCjo A-B 190OMHz NV ANTENNA MOUNTED FREQUENCY MFR. MODEL QUANTITY <br /> ON NEW PIPE ALPHA 1900 MHz ANDREW HBXX-9014DS-A2M 1 (PER SECTOR) 0' 31'-0• 50.9' -6' 0' <br /> MUjh) BETA 1900 MHz ANDREW HBXX-9014DS-A2M 1 (PER SECTOR) 120' 31'-0• 50.9" -4' 0' <br /> GAMMA 190D MHz ANDREW HBXX-9014DS-A2M 1 (PER SECTOR) 240' 31'-0• 50.9" 0' 0' <br /> EXISTING �� (1'PL11VGANTENNA <br /> p <br /> TOWER <br /> Ujy <br /> 1� <br /> �G <br /> mUE .w.mc <br /> P� NORH N0RT" SHEETTTTLE <br /> ANTENNA PLANS AND <br /> REPLACE EXISTING CDMA 3-5 NEW SPRINT 190OMHz <br /> 2 ANTENNA WITH NEW SPRINTA_6 RRU (1 PER SECTOR) S C H E D U L E S <br /> A-8 19DOMHz W ANTENNA MOUNTED <br /> ON NEW PIPE <br /> SHEET NUMBER REVISION: <br /> • A-4 <br /> X17•SCALE NOT TO SCALE ° <br /> 11 x34•SCALE: NOT TO SCALE NEW ANTENNA PLAN(FINAL) 3 NOTES&ANTENNA SCHEDULE 4 1253— <br /> 11 <br /> THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERWCES IS STRICTLY PROHIBITED. if/ <br /> t <br />
The URL can be used to link to this page
Your browser does not support the video tag.