2009 Washington Stategy Code Compliance Form for NonresidentiaLmad Multifamily Residential
<br /> • • • 9T.-TOK"ll M _ _ - - -= - M
<br /> 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010
<br /> Prescriptive Spaces Occupancy: O Warehouse or Parking Garage Other
<br /> Qualification Checklist Lighting 7 Check if 95%or more of fixtures comply Aith 1,2 or 3 and rest are ballasted
<br /> Note:If occupancy type is"Other"and fixture Fixtures:
<br /> answer is checked,the number of fixtures in (Section 1.Fluorescent fixtures with a)1 or 2 two lamps,b)reflector or towers,
<br /> the space is not limited by Code. Clearly 1521) c)5-60 watt T-1,T-2,T-4,T-5,T-8,or CFL lamps,and d)hard-wired electronic
<br /> indicate these spaces on plans. If not dimming ballasts. Screw-in CFL fixtures and tracking lighting do not qualify.
<br /> qualified,do LPA Calculations. 2. Metal Halide with a)reflector b)ceramic MH lamps<=150w c)electronic ballasts
<br /> 3. LED lights.
<br /> TABLE 15-1 Unit Li htin Power Allowance LPA
<br /> Use LPA W/ft Use LPA W/ft
<br /> Automotive facility 0.85 Office buildings,office/administrative areas in facilities 0.91
<br /> of other use types(including but not limited to schools,
<br /> hospitals,institutions,museums,banks,churches)5
<br /> Convention center 1.10 Parking garages 0.20
<br /> Courthouse 1.10 Penitentiary and other Group 1-3 Occupancies 0.90
<br /> Cafeterias,fast food establishments , 1.20 Police and fire stations 0.90
<br /> restaurants/bars5
<br /> Dormitory 0.85 Post office 1.00
<br /> Dweling Units 1.00 Retail , retail banking,mall concourses,wholesale 1.33
<br /> stores(pallet rack shelving)
<br /> Exercise center 0.95 School buildings(Group E Occupancy only),school 1.00
<br /> classrooms,day care centers
<br /> Gymnasia,assembly spaces 0.95 Theater,motion picture 0.97
<br /> Health care clinic 1.00 Theater, performing arts 1.25
<br /> Hospital, nursing homes,and other Group 1-1 and 1.20 Transportation 0.80
<br /> 1-2 Occupancies
<br /> Hotel/motel 1.00 Warehouses 0.50
<br /> Laboratory spaces(all spaces not classified 1.62 Workshops 1.20
<br /> "laboratory"shall meet office and other appropriate
<br /> tate ories
<br /> Laundries 1.20
<br /> Libraries5 1.20 Plans Submitted for Common Areas Only'
<br /> Manufacturing facility 1.20 Main floor building lobbies (except mall concourses)- 1.10
<br /> Museum 1.00 Common areas,corridors,toilet facilities and 0.80
<br /> washrooms, elevator lobbies
<br /> Footnotes for Table 15-1
<br /> 1) In cases in which a general use and a specific use are listed,the specific use shall apply. In cases in which a use is not mentioned
<br /> specifically,the Unit Power Allowance shall be determined by the building official.This determination shall be based upon the most
<br /> comparable use specified in the table.See Section 1512 for exempt areas.
<br /> 2) The watts per square foot may be increased,by 2%per foot of ceiling height above 20 feet,unless specifically directed otherwise by
<br /> subsequent footnotes.
<br /> 3) Watts per square foot of room may be increased by 2%per foot of ceiling height above 12 feet.
<br /> 4) For all other spaces,such as seating and common areas,use the Unit Light Power Allowance for assembly.
<br /> 5) Watts per square foot of room may be increased by 2%per foot of ceiling height above 9 feet.
<br /> 6) Reserved.
<br /> 7) For conference rooms and offices less than 150ft2 with full height partitions,a Unit Lighting Power Allowance of 1.1 w/ftz may be used.
<br /> 8) Reserved.
<br /> 9) For indoor sport tournament courts with adjacent spectator seating over 5,000,the Unit Lighting Power Allowance for the court area is
<br /> 2.60 W/ftz.
<br /> 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
<br /> walls or at least three-quarter-height partitions(transparent or opaque)and lighting for free-standing display where the lighting moves
<br /> with the display are exempt.
<br /> An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically
<br /> designed and directed to highlight merchandise. The following additional wattages apply:
<br /> L 0.6 watts per square foot of sales floor area not listed in items ii and iii below;
<br /> ii. 1.4 watts per square foot of furniture,clothing,cosmetics or artwork floor area;or
<br /> iii.2.5 watts per square foot of jewelry,crystal or china floor area.
<br /> The specified floor area for items i,ii,or iii above,and the adjoining circulation paths shall be identified and specified on building plans.
<br /> Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major
<br /> circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I,ii,or iii plus an additional
<br /> 1,000 watts for each separate tenant larger than 250 square feet in area.
<br /> The additional wattage is allowed only if the merchandise display luminaires comply with all of the following:
<br /> (a)Located on ceiling-mounted track or directly on or recessed into the ceiling itself(not on the wall).
<br /> (b)Adjustable in both the horizontal and vertical axes(vertical axis only is acceptable for fluorescent and other fixtures with two
<br /> points of track attachment).
<br /> This additional lighting power is allowed only if the lighting is actually installed and automatically controlled,separately from the general
<br /> lighting,to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be
<br /> used for any other purpose.
<br /> 1, 3l