y POBL/C WORKS <br /> February 7, 2013 <br /> Mr. Gary Swett <br /> 2230 Madison St. <br /> Everett, WA 98203 <br /> RE: Project: Restore Condemned Duplex and Office Mixed Use <br /> Job Address: 2918 Hoyt Ave. <br /> Plan Check No: CW1210-004 <br /> Dear Mr. Swett: <br /> Thank you for the January 22nd resubmittal. I believe you have covered all of Meg's concerns. <br /> I have to add a few more. <br /> 1. The front door to the flower shop should include an 18" maneuverability clearance on <br /> the latch side in accordance with ANSI A117.1, 404.2.3. <br /> 2. The proposed water closet does not appear to meet the minimum requirements of IBC <br /> Chapter 29 (State Amendment), which requires minimum fixtures for the store, or IBC <br /> 1109.2, which requires facilities to be accessible. Note that IBC 2902.1.1 does not allow <br /> fixtures only accessible to private offices to be counted for compliance. <br /> 3. Since the occupancy separation is a fire "barrier" and not a fire "wall", the 3/4 hour <br /> window (W-105) would not be required on the south side. <br /> Please call me at 425-257-7264 if you have any questions. Also, please provide two copies of <br /> any revisions. <br /> Sincerely, _ � h <br /> Steve Miller <br /> Associate Engineer <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> S:\]Common\Clerical\SMiller\CW]210-004(2918 Hoyt Ave.).doc <br />