Laserfiche WebLink
13, All food service equipment must be listed by the National Sanitation Foundation (NSF) or equivalent <br /> for its intended use. The ChocoVision tempering machine, model #C116Delta110V, was not found <br /> in the current NSF or equivalent listings. This equipment must be replaced with NSF or equivalent <br /> listed equipment or documentation must be submitted which demonstrates NSF equivalency. <br /> Manufacturer names and model numbers for replacement equipment or equipment documentation <br /> must be submitted. Originally submitted manufacturer names and model numbers should be <br /> rechecked to assure the information submitted is accurate. Please note that subsidiary <br /> manufacturers are often not found in the NSF and equivalent listings The manufacturer name <br /> should be verified and the parent company name submitted if one is found <br /> 14. Extra k�lull protection; is 'r quired on walls behind Gil sinks, ii is hiding r eStr oo i I hal lU1fJaSh Sinks, and <br /> food preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass- <br /> reinforcedplastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall <br /> behind counter top equipment taller than 16 inches. Wall protection behind mop sinks must cover <br /> the entire splash zone. Plastic coated hardboard is not acceptable. <br /> 15. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surfaced with G durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 16. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 17. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 18. All light fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br /> 19. Plumbing must meet state and local codes, <br /> 20. The ventilation system shall be installed and operated to meet applicable building, mechanical, and <br /> fire codes. <br /> A preoperational inspection is required prior to operating permit issuance and approval to open <br /> for business. At the time of inspection the construction of the food service establishment must be <br /> complete and all equipment must be in place and in proper operating condition. Incomplete construction <br /> or equipment operation will res!It in a $168.00 re-ir—pection fee C^~+act the Food Program office a <br /> rr-......_, y. ...�......, 1 1 <br /> minimum of one week in advance to schedule an appointment for the preoperational inspection. <br /> The preoperational inspection will ensure compliance with the Rules and Regulations of the State <br /> Board of Health for Food Service Sanitation. <br /> Changes or additions to the approved plans or equipment require pre-approval from the Snohomish <br /> Health District prior to implementation of the changes. <br /> Please contact me if you have any questions. My office number is 425.339.8742 and my email address <br /> is ehagedorn(c),snohd.org. <br /> Sincerely,_ <br /> y,- <br /> Elaine Hagedorn, RS <br /> Environmental Health Specialist <br /> Food Establishment Plan Review <br /> EH/sm <br /> Enclosure: Permit application and current fee schedule <br /> cc: City of Everett Building Department <br />