My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1122 INDUSTRY ST WESTERN SYSTEMS 2016-09-30
>
Address Records
>
INDUSTRY ST
>
1122
>
WESTERN SYSTEMS
>
1122 INDUSTRY ST WESTERN SYSTEMS 2016-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2016 2:49:52 PM
Creation date
9/30/2016 2:49:32 PM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1122
Tenant Name
WESTERN SYSTEMS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iii) Exit signs should be shown at each egress door leading from the room to the <br /> exterior exit doors... <br /> Exit signs have been added. See revised floor plan drawing A2.2 & A2.3 for <br /> exit sign locations. <br /> iv) Emergency lighting should be shown within the room and each path leading to <br /> the exterior exit doors... <br /> Emergency lighting has been added. See revise drawing A2.2 and A2.3 for <br /> exit lighting locations. <br /> 3) For clarity, the structural exterior deck members should be shown as pressure treated... <br /> Exterior deck has been removed and replaced with landscaping at existing <br /> loading dock. See revised drawing A1.1 and A2.1. All exterior deck information <br /> has been removed or should be disregarded. <br /> 4) The enclosed space under the stairs should be separated from the stairs by minimum <br /> one-hour fire resistive construction... <br /> Note had been added to plan to indicate 1-hour construction at enclosed space <br /> under stairs. See Stir sections 1, 2 & 3 on drawing A4.2. <br /> 5) It should be verified that the elevator cab is capable to accommodate a stretcher... <br /> Elevator cab has been sized to accommodate a 24"x84" stretcher. <br /> 6) Door 123A should be provided with a minimum of 18"clear space from the pull side... <br /> Room 123 has been changed to storage and the closer for door 123A has been <br /> removed from the hardware schedule. Server has been moved to room 117. <br /> 7) The heights of the lavatories, urinals and toilets should be shown on the plans... <br /> Fixture heights have been added. See revised drawing A5.2 for fixture elevation <br /> information. <br /> 8) The plans should indicate that the walls between the warehouse and office will be <br /> insulated with R-19... <br /> Wall separating ware house and office areas will be insulated to R-19 value. See <br /> revised drawings A2.2, A2.3 and A4.1 for insulation information. <br /> 9) Window U factors should be noted on the plans for the proposed glazing... <br /> See revised building elevation drawing AM for U-values of proposed glazing. <br /> Hope this response meets your approval. Please let me know if you have .any questions or <br /> need anything else. <br /> Sincerely, <br /> zf � <br /> ley <br /> VC <br /> Ryan Ellinghaus <br /> 2812 Architecture <br /> 2812 Colby Avenue Everett WA 98201 <br /> P (425)252-2153 F (425)742-8130 ,` www.2812architecture.com <br /> "I �j <br />