My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1122 INDUSTRY ST WESTERN SYSTEMS 2016-09-30
>
Address Records
>
INDUSTRY ST
>
1122
>
WESTERN SYSTEMS
>
1122 INDUSTRY ST WESTERN SYSTEMS 2016-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2016 2:49:52 PM
Creation date
9/30/2016 2:49:32 PM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1122
Tenant Name
WESTERN SYSTEMS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Address 1122 Industry St. Date 6/3/2013 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. <br /> Applicability Code Section Code Provision Information Required Location Building Department <br /> (yes,no,na)1 1 1 1 on Plans Notes <br /> GENERAL PROVISIONS,CONTINUED <br /> HVAC System Controls&Criteria,Continued <br /> C403.2.12 Variable flow control- Indicate fan&pump motors requiring VF control&method(VSD or equiv <br /> N/A fans/pumps controls <br /> C403.2.12.1 Variable flow control- Indicate cooling tower fans requiring variable flow control and method <br /> N/A cooling towers <br /> C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and <br /> N/A cooling demand;or exception taken <br /> C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys.>110,000 <br /> N/A btuh <br /> N A C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability <br /> / for trendina and demandresoonse setpointn <br /> Ducting Systems <br /> C403.2.7.1& Duct construction Indicate all ductwork constructed and sealed per IMC,C402 leakage M 1 <br /> Yes C403.2.7.3 requirements and IBC vapor retarder requirements <br /> N/A 403.2.7.3.1- Duct pressure Identify location of low,medium and high pressure ductwork on plans <br /> classifications <br /> C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide <br /> N/A test test results to jurisdiction when completed <br /> Yes C403.2.7.1/ Duct insulation Indicate R-value of insulation on ductwork M1 <br /> Piping Systems <br /> N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping <br /> N/A C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage/degredation <br /> weather <br /> SIMPLE SYSTEMS <br /> Qualifying Systems <br /> C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, M1 <br /> Yes systems does not have active humidifcation or simultaneous heating/cooling <br /> N/A C403.3 Qualifying 2-pipe heating Verify 2-pipe heating-only system does not exceed capacity limits <br /> systems <br /> N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 <br /> Simple System Economizers <br /> Indicate cooling systems requiring economizer controls;note in equip <br /> Yes C403.3.1 Air economizer required sched. M 1 <br /> Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100%OSA,or exception M 1 <br /> C403.3.1.1.3 Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 <br /> Yes controls <br /> C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with M1 <br /> Yes operation capacity>65,000 btuh <br /> Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with M1 <br /> x ti n <br /> COMPLEX SYSTEMS <br /> Complex System Economizers <br /> C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip M1 <br /> Yes sched. <br /> C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not <br /> Yes impact increase building heating energy usage during normal operation M1 <br /> Integrated economizer Indicate capability for partial economizer operation for air or water econo <br /> Yes C403.4.1.3 M1 <br /> operation s stems <br /> Moved Water economizer capacity Indicate water econo capable of 100%cooling capacity at 50°F db/45°F wb <br /> N/A OSA <br /> C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure <br /> N/A maximum pressure drop drop limit <br /> N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with <br /> x n <br />
The URL can be used to link to this page
Your browser does not support the video tag.