My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2018-11-08
>
Address Records
>
LAKE HEIGHTS DR
>
2020
>
WATERFORD PLACE APTS
>
2020 LAKE HEIGHTS DR WATERFORD PLACE APTS 2018-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2018 8:31:46 AM
Creation date
9/30/2016 3:33:33 PM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2020
Tenant Name
WATERFORD PLACE APTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� � �� �� <br /> SK-4 8� SK-4E <br /> Fire Control Panel <br /> Engir.eering Specifications <br /> The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK-4/E.The system shall <br /> contain a fire alarm control panel capable of operating and supervising smoke detection devices,alarm notification devices,and an on- <br /> board annunciator. It shall be compatible with a digital communicator accessory. <br /> The fire alarm control panel shall have a power limited supply,four Class B initiation circuits which shall accommodate heat detectors, <br /> smoke detectors, and manual pull stations.Smoke detection shall be achieved with either 2-or 4-wire detectors that are compatible with <br /> the system.The initiation inputs shall be programmable as 1)verifcation zones in which detectors are automatically reset one time <br /> before signaling an alarm condition;or 2)combination waterFlow supervisory zones that allows the FACP to distinguish between an alarm <br /> switch (waterflow device)and a supervisory switch(tamper) installed on the same circuit.The FACP shall have two 2.5 amp or 5 amp <br /> (with an additional optional standard transformer)programmable notification outputs. It shall have dedicated relays for alarm,trouble, antl <br /> supervisory. It shall have two power outputs, one resettable and one non-resettable,each rated at 500 mA. <br /> The FACP shall have an on-board annunciator to indicate alarm,supervisory,trouble,and maintenance conditions.The annunciator must <br /> include LEDs for AC,GENERAL TROUBLE,ALARM SILENCE,WALK TEST, EARTH FAULT,AND LOW BATTERY.The annunciator <br /> shall also contain LEDs to annunciate fire alarms,troubles, supervisory, and maintenance by zone.The FACP must be fully operational <br /> from the annunciator and include buttons forACKNOWLEDGE,ALARM, SILENCE, RESET,and WALK TEST.The annunciator must also <br /> have separate DISABLE switches for each zone and notification circuit. <br /> Electrical Specifcations(cont) <br /> Battery Approvals SK-4XLM <br /> Type: Sealed lead acid only NFPA 72; UL Listed; <br /> Charging Circuit: 27.6 VDC @ 0.8A LED Interface Module. <br /> CSFM 7165-0559: 145; <br /> max normal flat charge MEA 297-01-E-3 SK-XRM24 <br /> Charging Capacity: 18 AH 110 Volt Transformer 3-6A. <br /> Size: 7 AH max allowed in FACP. Ordering Information <br /> Larger batteries can housed SK-4 SK-XRM24E <br /> in an RBB accessory cabinet 120 VAC Four Zone Conventional 220 Volt Transformer 3-6A. <br /> Compatible Initiating and NAC FACP SK-RZA4 <br /> Devices Remote Annunciator. <br /> See SK document PN 52612. SK-4E <br /> 240 VAC Four Zone Conventional SK-4XZM <br /> Mechanical Specifications FACP Zone Relay Module. <br /> Cabinet Backbox Dimensions: <br /> 14.5"W x 15" H x 3" D Accessories RBB <br /> (36.83 W x 38.10 H x 7.62 D cm) SK-DP2/4 Remote Battery Box Accessory <br /> Cabinet Door: Dress Panel.Allows access to the Cabinet. Use if back up batteries are <br /> 14.677"W x 15.342" H x 0.375" D panel controls but restricts access to too large to fit into FACP cabinet. <br /> (37.28 W x 38.97 H x 0.95 D cm) system wiring. Dimensions: 16"W x 10"H x 6"D <br /> Cabinet Color: Red SK-CAC4 Digital Communicator Accessories <br /> Installation Class A Convertor. Converts Style B 5104B <br /> The SK-4/E can be surface mounted (Class B) IDCs to Style D (Class A)and Six-zone fire control communicator <br /> using two key slots at the top of the Style B (Class B) NACs to Style Z <br /> backbox and two additional 0.25" (Class A) 5129 <br /> diameter holes at the bottom, or semi- Four channel slave fire communicator <br /> flush mounted using the optional Trim SK-4XTM <br /> Ring P/N TR-1-R Transmitter Module. Provides a <br /> supervised output for local energy <br /> municipal box transmitter and alarm <br /> and trouble reverse polarity. <br /> SILENT This document is not intended to be used For installation purposes.We try MADE IN AMERICA <br /> to keep our product information up-to-date and accurate.We cannot cover <br /> KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350305 Rev.E <br /> subject to change without notice. For more information,contact Silent <br /> by Hnneywell Knight 12 Clintonville Road, Northford,CT 06472-7161 �O 2012 Honeywell International Inc. <br /> Phone:(800)328-0103,Fax: (203)484-7118.www.silentknight.com <br /> % �/� � � <br /> � r/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.