1. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH 1. PROVIDE#2 AWG TINNED SOLID,BARE COPPER WIRE PERIMETER A AMPERE <br /> ME LATEST EDITION OF THE NATIONAL ELECTRICAL CODE(NEC). GROUND RING,30"BELOW GRADE. AWG AMERICAN WIRE GAUGE <br /> BCW BARE COPPER WIRE(SOLID TINNED) <br /> 2. COMPLY WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE, 2. PROVIDE#2 COPPER WIRE GROUND JUMPER AT"BTS"EQUIPMENT BSCW BARE STRANDED COPPER WIRE <br /> THE REQUIREMENTS OF ALL APPLICABLE MUNICIPAL AND STATE CODES PLINTH USING EXISTING TAPPED HOLES BTS BASE TRANSCEIVER STATION <br /> AND REGULATIONS,AND UTILITY GUIDELINES. C.O. CONDUIT ONLY VerlLn wireless <br /> 3. PROVIDE#2 AWG TINNED SOLID,BARE COPPER WIRE BONDING EMT ELECTRICAL METALLIC TUBING GFI GROUND FAULT INTERRUPTER we nevef stop waking/or you. <br /> 3. PERFORM ALL VERIFICATION,OBSERVATIONS,TESTING AND JUMPER BETWEEN GROUND RINGS, 30"BELOW GRADE.TYPICAL 3245158TH AVE SE,SUITE 231 <br /> EXAMINATION OF WORK PRIOR TO THE ORDERING OF ELECTRICAL OF TWO(2)PLACES. GPD GROUND <br /> GPS GLOBAL POSITIONING SYSTEM BELLEvuE,WA 98008 <br /> EQUIPMENT AND THE ACTUAL CONSTRUCTION.ISSUE A WRITTEN NOTICE <br /> GRC GALVANIZED RIGID CONDUIT PROJECT CONSULTANTS: <br /> OF ALL FINDINGS TO THE CONSTRUCTION MANAGER LISTING ALL 4. PROVIDE#2 COPPER WIRE GROUND CONNECTIONS FROM IMT INTERMEDIATE METAL TUBING <br /> MALFUNCTIONS,FAULTY EQUIPMENT AND DISCREPANCIES. GROUND BAR AT BTS AND BASE OF MONOPOLE TO GROUND RING. PCS PERSONAL COMMUNICATION SERVICE <br /> 4. ALL ELECTRICAL/TELCO CONDUIT SHALL BE RIGID METAL CONDUIT TYPICAL OF TWO(2)EACH GROUND BAR. PPC POWER PROTECTION CABINET <br /> PRC PRIMARY RADIO CABINET PACIFIC CORPORATION <br /> (RMC)TYPE CONFORMING TO UNDERWRITERS LABORATORIES 5. GROUND WATER TANK AT THREE(3)PLACES WITH#2 COPPER WIRE AT 6" RGS RIGID GALVANIZED STEEL <br /> STANDARD UL-6 AND ASTM A-135:ALL CONDUITS SHALL COMPLY WITH TYP TYPICAL <br /> 0) <br /> NEC,ARTICLE 346.ALL RIGID AND FLEXIBLE CONDUITS,AND COUPLINGS ABOVE GRADE. <br /> USE UNDERGROUND SERVICE ENTRANCE CABLE <br /> SHALL BE HOT DIPPED GALVANIZED HAVING A HARD BAKED ENAMEL OR UGP UNDERGROUND POWER PLANS PREPARED BY: <br /> HEAVY LACQUER FINISH,BOTH INSIDE AND OUTSIDE. COUPLINGS SHALL 6. PROVIDE COAX GROUND KITS AND GROUND BAR AT TOP AND UGT UNDERGROUND TELEPHONE <br /> BE THREADED TYPE,GALVANIZED AND MADE FROM SAME GRADE OF MILD BOTTOM OF MONOPOLE;ATTACH BETWEEN GROUND BARS WITH V VOLT <br /> STEEL AS RMC. ALL BENDS SHALL BE 30"MINIMUM RADIUS. (2)#2 AWG TINNED SOLID,GREEN SHIELDED COPPER WIRE. WP WEATHERPROOF �� coo NERS QONE <br /> 5. ALL WIRING SHALL BE STRANDED COPPER WITH MINIMUM 600V 7. ELECTRICAL SERVICE GROUND;TWO(2)GROUND RODS AT MIN 16928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> A M72 <br /> INSULATION(UNLESS OTHERWISE NOTED). 6'-0"APART. CADWELD TO GROUND RING. AT REMOTE ®M METER WPHONE:I 25.W.1732 <br /> PHONE:425.487.1732 <br /> ELECTRICAL RACK ONLY. <br /> 6. NEUTRAL SHALL BE COLOR CODED,INSULATION SHALL BE CROSS-LINKED n CIRCUIT BREAKER EMAIL:ceiNERS ONE-ENGR.CO <br /> W W W.CORNERSTONE-ENGR.COM <br /> POLYETHYLENE. 8. TELCO SERVICE GROUND,CADWELD TO GROUND RING. MGB MASTER GROUND BAR PROJECT INFO: <br /> 7. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF <br /> NOT USED 9. CONNECT COAX GROUND KITS TO COAX JUST ABOVE BEND, Tr 1/4"x4"x24"COPPER <br /> UNDERGROUND SERVICES.SERVICE LOCATIONS TO BE CONFIRMED 22x34 SCALE:NTS 11x17 SCALE:NTS CONNECT TO GROUND BAR. EGB EQUIPMENT GROUND BAR <br /> PRIOR TO CONSTRUCTION. Tr 1/4"x4"x12"OR 1/4"x4"x20"COPPER <br /> 8. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING,FILING,AND 10. GROUND MONOPOLE FOUNDATION STEEL,MINIMUM AT 2-PLACES EXPOSED WIRING SEA FLUKE <br /> WITH#2 COPPER WIRE. <br /> FEES IN CONJUNCTION WITH THE PROJECT. MATCH SURFACE ----- UNDERGROUND WIRING <br /> MATERIALS 11. ALL GROUND CONNECTIONS TO EQUIPMENT TO BE MECHANICAL ■ CADWELD 2215 MERRILL CREEK PARKWAY <br /> 9. THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH 2'-0" EVERETT,WA 98203 <br /> THE PROPER AUTHORITIES AND INFORM VERIZON 24-HOURS IN ADVANCE. • MECHANICAL CONNECTION <br /> ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO FINISH GRADE 12. MAIN GROUND LOOP AND CONDUCTOR CONNECTING COPPER SNOHOMISH COUNTY <br /> 5/8"x8'COPPER CLAD <br /> GROUND BUSES TO BE#2/2 BARE COPPER WIRE(BCW). ® <br /> THE OWNER'S REPRESENTATIVE WITHIN 24-HOURS AFTER THE \\ \\\\j\\j /\\ \\j\\j�� STEEL GROUND ROD ISSUED FOR: <br /> X <br /> INSPECTION HAS TAKEN PLACE. /\ \//\ //\//\//\� 13. ALL GROUND RODS SHALL BE AT LEAST 10 FEET APART. (a INSPECTION PORT <br /> CONSTRUCTION <br /> 10. ALL EQUIPMENT,WIRING,AND MATERIALS MUST HAVE A UL LABEL _ __ EXOTHERMIC(CADWELD) <br /> \ \ \ 14. ALL GROUND MUST COMPLY WITH VERIZON AND EQUIPMENT - BELOW GROUND REV:=DATE:=ISSUED FOR: BY: <br /> c EXCAVATION MANUFACTURERS GROUNDING STANDARDS AND REQUIREMENTS. 1 GROUND <br /> 11. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED io i7 \ \ \ \ <br /> JOURNEYMEN AND PERFORMED IN A WORKMANLIKE MANNER AND SHALL io \ /\� /\ WARNING TAPE <br /> PROCEED IN AN ORDERLY MANNER SO AS NOT TO HOLD UP THE COMPACTED FILL <br /> PROGRESS OF THE PROJECT. \\ \ pQ 02-03-14 FINAL EJS <br /> 12. THOROUGHLY TEST ALL LINES FEEDERS,EQUIPMENT,AND DEVICES WITH UNEXCAVATED/ Q �O,' \\�` AREA Q 01.17.14 REVISED �B <br /> MAXIMUM LOADS TO ASSURE PROPER OPERATION PRELIMINARY <br /> A COMPACTED <br /> 13. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO 2"0 FIBER \/ /\\/\\/\\/\\� SAND gQ 01-09-14 PRELIMINARY LJS <br /> TERMINATION WITHOUT SPLICES OPTIC CONDUIT /\�/ / / /�/ <br /> Ot-03-14 PRELIMINARY JEG <br /> 14. PROVIDE PULL BOXES WHERE SHOWN AND/OR WHERE REQUIRED BY <br /> 2"0 POWER <br /> CODES AND/OR UTILITY COMPANIES. CONDUIT <br /> DRAWN BY:=CHK.: APV. <br /> 15. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL L JEG I EJS MWO <br /> EQUIPMENT TO AVOID LOCATION CONFLICTS.CONTRACTOR SHALL CURRENT ISSUE DATE: <br /> VERIFY ALL LOCATIONS UTILITY TRENCH 7 GROUNDINS NOTES 6 GROUNDING SYMBOLS 5 02-03-14 <br /> 16.ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES,J-BOXES,EQUIPMENT 22x34 SCALE:3/4"=V-0" 11x17 SCALE:3/8"=1'-0" 22x34 SCALE:NTS 117 SCALE:NTS 22x34 SCALE NTS 711 x 17 SCALE:NTS LICENSURE: <br /> BOXES,AND CABINETS WITH APPROVED PLASTIC TAGS. <br /> 17. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE NOTE: <br /> WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER. VERIFY ALL FINAL INSTALLATION REQUIREMENTS WITH �ESLEy <br /> ELECTRIC UTILITY.PROVIDE ENCASEMENT OF"USE" Q e�� H�Odd' <br /> 18. ALL FIRE RATED WALL AND FLOOR PENETRATIONS ARE TO BE CAULKED CONDUCTOR WITH 1 1/2"GRC WHENEVER CONDUCTOR <br /> AND SEALED WITH A FIRE RESISTANT CAULKING TO MAINTAIN THE IS EXPOSED IN ACCORDANCE WITH NEC 300-5(d) <br /> INTEGRITY OF THE FIRE SEPARATION. 200A SERVICE PANEL& 'S' <br /> 200A METER <br /> 19.UTILIZE SONNEBORN TYPE NP-1 CAULKING FOR SEALING ALL EXTERIOR FEEDER SCHEDULE MANUEL TRANSFER SWITCH SS%NAL OZ0�1A <br /> WALL PENETRATIONS (�D 3#2 CU TYPE"USE"-3"C <br /> 3#2 CU TYPE"US "-1 1/4"C (E)ELECTRICAL SOURCE POWER CABINET DRAWING INFORMATION: <br /> E <br /> 20.SUBCONTRACTOR SHALL SUPPLY AND INSTALL A 200#RATED NYLON O 3#2 CU AND 1#6 E' -1 1/4"C M 2 DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> PULL CORD FOR FULL LENGTH OF ALL EMPTY CONDUIT ORAS REQUIRED ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> BY LOCAL UTILITY COMPANY. ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> 1 FINISH GRADE DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> 1 ITHE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> 3 IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS <br /> STRICTLY PROHIBITED. <br /> I <br /> L - - - - - - - - - - J I DRAWING TITLE: <br /> 120/240V 10 3W UNDERGROUND 1 1#6 CU TO 5/8"x8'-0"LONG DRIVEN <br /> SECONDARY SERVICE ENTRANCE. GROUND ROD AND CADWELD TO ELECTRICAL NOTES& <br /> EXTERIOR GROUND RING SINGLE LINE DIAGRAM <br /> DRAWING NUMBER: <br /> E-1 0 <br /> ELECTRICAL SPECIFICATION 4 SINGLE LINE DIAGRAM <br /> 22x34 SCALE:NTS 11x17 SCALE:NTS 22x34 SCALE:NTS 11x17 SCALE:NTS CEI JOB NUMBER NB 13-20109 <br />