ELECTRICAL NOTES <br />1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL <br />ELECTRICAL CODES AND ALL LOCAL AND STATE CODE, LAWS. AND <br />ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC <br />STANDARDS. <br />2. CONTRACTOR SHALL COORDINATE WITH LOCAL POWER COMPANY FOR REQUIREMENTS OF <br />POWER SERVICE L1NE TO THE MEfER BASE, WHEN REOUIRED. POWER SERVICE <br />RE�UIREMENT IS COMMERCIAL. AC NOMINAL 120/208 VOLT OR 120/240 VOLT, SINGLE <br />PHASE WITH 200 AMP RATING. <br />3. CONTRACTOR SHALL COORDINATE WITH LOCAL TELEPHONE COMPANY FOR SERVICE LWE <br />REQUIREMENTS TO TERMINATE AT THE PPC CABINEf. <br />4. CONTRACTOR SHALL FURN�SH AND INSTALL ELECTRIC METER BASE AND 200A DISCONNECT <br />SWITCH PER SITE PLAN DETNL DRAWINGS AND PER LOCAL UTILIN COMPANIES <br />SPECIFICATION, WHEN REOUIRED. THE MEfER BASE SHOULD BE LOCATED IN A MANNER <br />WHERE ACCESSIBLE BY THE LOCAL POWER COMPANY. <br />5. LOCAL POWER COMPANY SHALL PROVIDE 200 AMP ELECTRIC MEfER. CONTR4CTOR SHALL <br />COORDINATE INSTALLATION OF MEfER WITH LOCAL POWER COMPANY. <br />6. UNDERGROUND POWER AND TELCO SERVICE LWES SHALL BE ROUTED IN A COMMON <br />TRENCH. ALL UNDERGROUND CONDUR SHALL BE PVC SCHEDULE 40 AND CONDUIT <br />EXPOSED ABOVE GROUND SHALL BE GALVANIZED RIGID STEEL TUBING UNLESS OTHERWISE <br />INDICATED. <br />7. ALL TELCO CONDUIT LINES SHALI BE 4" SCH. 40 PVC CONDUIT UNLESS OTHERWISE <br />INDICATED. THE TELCO CONDUIT FROM THE PPC SHALL BE ROUTED AND TERMINATED AT <br />DESIGNATED TELCO DEMARCATION OR 2—FEEf OUTSIDE FENCED AREA, NEAR UTIL1IY POLE <br />(W FENCED AREA), OR END CAP OFF AND PROVIDE MARKER STAKE PAINTED BRIGHT <br />ORANGE WITH DESIGNATION FOR TELCO SERVICE. <br />8. CONDUITS INSTALLED AT PCS EQUIPMENT ENDS PRIOR TO THE EQUIPMENT INSTALLATION <br />SHALL BE STUBBED AND CAPPED AT 6" ABOVE GRADE OR PLATFORM. IF SERVICE LINES <br />CAN'T BE INSTALLED INITIALLY, PROVIDE NYLON PULL CORD IN CONDUITS. <br />9. THE SPRINT CABINEf, WCLUDING 200 AMP LOAD PANEL AND TELCO PANEL, SHALL BE <br />PROVIDED BY OWNER AND WSTALLED BY THE CONTRACTOR. CONTRACTOR IS TO INSTALL <br />BREAKER(S) NOT PROVIDED BY MANUFACTURER. SEE PANEL SCHEDULE ON THIS SHEEf <br />FOR BREAKER REQUIREMENTS. <br />10. LOCATION OF ELECTRIC MEfER AND DISCONNECT SWITCH TO BE PROVIDED BY GENERAL <br />CONTRACTOR. <br />11. CONTR4CTOR SHALL INSPECT THE EXISTING CONOITIONS PRIOR TO SUBMITTING BID. ANY <br />QUESTIONS ARISINC DURING THE BID PERIOD IN REGARDS TO THE <br />CONTRACTORS FUNCTIONS. THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO <br />THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE <br />PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. <br />12. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE <br />APPROXIMATE AND SHALL BE COORDINATED WITH FlELD CONDITIONS PRIOR TO <br />ROUGH—IN. <br />13. THE CONDUIT RUNS !S SHOWN ON THE PLANS ARE APPROXIMATE EXACT LOCATION <br />AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. <br />14. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REqUIRED BY NEC. <br />22"x34" SCALE: NOT TO SCALE <br />11"xi7" SCALE: NOT TO SCALE <br />ELECTRICAL NOTES �CON'T� <br />16. ALL CONDUITS SHALL BE MEf WITH BENDS MADE IN ACCORDANCE WITH NEC <br />TABLE 346-10. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT <br />ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. <br />17. ALl CONDUIT TERMINATIONS SHALL BE PROVIDED WITH Pl.ASTIC THROAT <br />INSUTATING GROUNDING BUSHINGS. <br />18. ALL WIRE SHALL BE "TYPE THWN, SOLID. ANNEALED COPPER UP TO SIZE 1/10 <br />AWG (18 AND LARGER SHALL BE CONCENTRIC STRANDED) 75 DEGREE C, (167 <br />DEGREES F), 98' CONDUCTIVITY. MINIMUM {%12. <br />19. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES. J—BOXES, EQUIPMENT BOXES <br />AND CABINEfS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR <br />APPROVED EQUAL. <br />20. ALL NEW MATERIAL SHALL HAVE A U.L LABEL. <br />21. CONDUIT ROUGH—IN SHALL BE COORDINATED WITH THE MECHANICAL EOUIPMENT <br />TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTR4CTOR AND <br />COMPLY AS REQUIRED. <br />22. ALL PANEL OIRECTORIES SHALL BE NPEWRITfEN NOT HAND WRITfEN. <br />23. INSTALL AN EQUIPMENT GROUNDING CON�UCTOR IN ALL CONDUITS PER THE <br />SPECIFICATIONS AND NEC. THE EOUIPMENT GROUNDING CONDUCTORS SHALL BE <br />BONDED AT ALL JUNCTION BOxES. PULIBOxES, AND ALL DISCONNECT SWITCHES, <br />STARTERS, AND EQUIPMENT CABINETS. <br />24. THE CONTRACTOR SHALL PREPARE AS—BUILT DRAWINGS. DOCUMENT ANY AND ALL <br />WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS <br />CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. <br />25. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE <br />PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES INDICATING EQUIPMENT <br />CONTROLLED, BRANCH CIRWITS INSTALLED ON, AND PANEL FlELD LOCATIONS FED <br />FROM (NO E%CEPTIONS.) PROVIDE SAMPLE FOR CONSTRUCTION MANAGER'S <br />APPROVAL. <br />26. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY <br />WITH (ADA) AMERICANS WITH DISABILITIES ACT AS ADOPTED BY THE APPLICABLE <br />STATE. <br />27. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROl1GH <br />BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION <br />MANAGERS APPROVAL SLEEVES ANO/OR PENETRATIONS IN FIRE RATED <br />CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL <br />MAINTAW THE FIRE RATING OF THE WALL OR STRUCNRE. fILL FOR FLOOR <br />PENEfRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. <br />ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. <br />28. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EJ(ISTING) SHALL BE <br />FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER <br />PRIOR TO ROUGH—IN Of CONDUIT AND WIRE ALL EQUIPMENT SHALL BE <br />PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE <br />N�FORMANIONTAT THEGTIME�FOFH�ESIGN ANDASOMEAEQUIPM NT CHARACTERSTICS NOTES <br />MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). <br />29. LOCATION OF ALL OUTLET, BOXES, ETC., AND THE IYPE OF CONNECTION (PLUG <br />OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO <br />70 EXISTI�G UTILIN POWER <br />SOURCE <br />CLCCTRICAL NOTGS � ] <br />GENERAL CONTRACTOR TO CHECK REQUIREMENTS WITH LOCAL POWER COMPANY AND <br />JURISDICTION. ADDITIONAL SUB PANEL OFF THE PPC CABWEf MIGHT BE REQUIRED TO FEED <br />NEW NEfWORK VISION EQUIPMENT. <br />EXISTING 200A <br />METER/DISCONNECi SWITCH <br />200A 2 . <br />/\ <br />M 3 <br />EXISTWG SERVICE GROUN� J <br />CIRCUIT SCHEDULE <br />NO FROM TO CONPiGURATiON <br />O1 SOURCE METER CENTER EXISTING <br />2 METER DSC TRANSPER SWITCH & EXISTING <br />O � LOAD CENTER <br />TRANSFER SWITCH & GENERATOR <br />OO LOAD CENTER RECEPTICLE EXISTING <br />TRANSFER & LOAD NEW MM85 CABMET (3) b2 AWG, (1) j�8 GND IN <br />O CENTER SUB—PANEL 2" CONDUIT <br />TRANSFER & LOAD NEW BBU CABINET (3) �10 AWG, (1) �10 GND IN <br />O CENTER SUB—PANEL 1" CONDUIT <br />EXISTING LOADS (REFER TO <br />PANEL SCHEDULE <br />22"x34" SCALE NOT TO SCALE <br />11"x17" SCALE NOT TO SCALE <br />iHE INFORMA710N CONTAWED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN TNAT WHICH RELATES TO <br />ELECTRICAL PANEL SCHC��ULE I 2 <br />E%ISTING 200A GENERATOR <br />RECEPTACLE <br />TRANSFER SWITCH & LOAD <br />CENTER <br />SERVICES IS STRICTLY PROHIBITED <br />EL[CTRICAL ONE-LINE I�IAGRAM � 3 <br />