My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6515 MORGAN RD SPRINT ANTENNA 2018-11-19
>
Address Records
>
MORGAN RD
>
6515
>
SPRINT ANTENNA
>
6515 MORGAN RD SPRINT ANTENNA 2018-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 1:58:09 PM
Creation date
10/3/2016 3:52:12 PM
Metadata
Fields
Template:
Address Document
Street Name
MORGAN RD
Street Number
6515
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL NOTES <br />1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL <br />ELECTRICAL CODES AND ALL LOCAL AND STATE CODE, LAWS. AND <br />ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC <br />STANDARDS. <br />2. CONTRACTOR SHALL COORDINATE WITH LOCAL POWER COMPANY FOR REQUIREMENTS OF <br />POWER SERVICE L1NE TO THE MEfER BASE, WHEN REOUIRED. POWER SERVICE <br />RE�UIREMENT IS COMMERCIAL. AC NOMINAL 120/208 VOLT OR 120/240 VOLT, SINGLE <br />PHASE WITH 200 AMP RATING. <br />3. CONTRACTOR SHALL COORDINATE WITH LOCAL TELEPHONE COMPANY FOR SERVICE LWE <br />REQUIREMENTS TO TERMINATE AT THE PPC CABINEf. <br />4. CONTRACTOR SHALL FURN�SH AND INSTALL ELECTRIC METER BASE AND 200A DISCONNECT <br />SWITCH PER SITE PLAN DETNL DRAWINGS AND PER LOCAL UTILIN COMPANIES <br />SPECIFICATION, WHEN REOUIRED. THE MEfER BASE SHOULD BE LOCATED IN A MANNER <br />WHERE ACCESSIBLE BY THE LOCAL POWER COMPANY. <br />5. LOCAL POWER COMPANY SHALL PROVIDE 200 AMP ELECTRIC MEfER. CONTR4CTOR SHALL <br />COORDINATE INSTALLATION OF MEfER WITH LOCAL POWER COMPANY. <br />6. UNDERGROUND POWER AND TELCO SERVICE LWES SHALL BE ROUTED IN A COMMON <br />TRENCH. ALL UNDERGROUND CONDUR SHALL BE PVC SCHEDULE 40 AND CONDUIT <br />EXPOSED ABOVE GROUND SHALL BE GALVANIZED RIGID STEEL TUBING UNLESS OTHERWISE <br />INDICATED. <br />7. ALL TELCO CONDUIT LINES SHALI BE 4" SCH. 40 PVC CONDUIT UNLESS OTHERWISE <br />INDICATED. THE TELCO CONDUIT FROM THE PPC SHALL BE ROUTED AND TERMINATED AT <br />DESIGNATED TELCO DEMARCATION OR 2—FEEf OUTSIDE FENCED AREA, NEAR UTIL1IY POLE <br />(W FENCED AREA), OR END CAP OFF AND PROVIDE MARKER STAKE PAINTED BRIGHT <br />ORANGE WITH DESIGNATION FOR TELCO SERVICE. <br />8. CONDUITS INSTALLED AT PCS EQUIPMENT ENDS PRIOR TO THE EQUIPMENT INSTALLATION <br />SHALL BE STUBBED AND CAPPED AT 6" ABOVE GRADE OR PLATFORM. IF SERVICE LINES <br />CAN'T BE INSTALLED INITIALLY, PROVIDE NYLON PULL CORD IN CONDUITS. <br />9. THE SPRINT CABINEf, WCLUDING 200 AMP LOAD PANEL AND TELCO PANEL, SHALL BE <br />PROVIDED BY OWNER AND WSTALLED BY THE CONTRACTOR. CONTRACTOR IS TO INSTALL <br />BREAKER(S) NOT PROVIDED BY MANUFACTURER. SEE PANEL SCHEDULE ON THIS SHEEf <br />FOR BREAKER REQUIREMENTS. <br />10. LOCATION OF ELECTRIC MEfER AND DISCONNECT SWITCH TO BE PROVIDED BY GENERAL <br />CONTRACTOR. <br />11. CONTR4CTOR SHALL INSPECT THE EXISTING CONOITIONS PRIOR TO SUBMITTING BID. ANY <br />QUESTIONS ARISINC DURING THE BID PERIOD IN REGARDS TO THE <br />CONTRACTORS FUNCTIONS. THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO <br />THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE <br />PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. <br />12. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE <br />APPROXIMATE AND SHALL BE COORDINATED WITH FlELD CONDITIONS PRIOR TO <br />ROUGH—IN. <br />13. THE CONDUIT RUNS !S SHOWN ON THE PLANS ARE APPROXIMATE EXACT LOCATION <br />AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. <br />14. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REqUIRED BY NEC. <br />22"x34" SCALE: NOT TO SCALE <br />11"xi7" SCALE: NOT TO SCALE <br />ELECTRICAL NOTES �CON'T� <br />16. ALL CONDUITS SHALL BE MEf WITH BENDS MADE IN ACCORDANCE WITH NEC <br />TABLE 346-10. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT <br />ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. <br />17. ALl CONDUIT TERMINATIONS SHALL BE PROVIDED WITH Pl.ASTIC THROAT <br />INSUTATING GROUNDING BUSHINGS. <br />18. ALL WIRE SHALL BE "TYPE THWN, SOLID. ANNEALED COPPER UP TO SIZE 1/10 <br />AWG (18 AND LARGER SHALL BE CONCENTRIC STRANDED) 75 DEGREE C, (167 <br />DEGREES F), 98' CONDUCTIVITY. MINIMUM {%12. <br />19. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES. J—BOXES, EQUIPMENT BOXES <br />AND CABINEfS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR <br />APPROVED EQUAL. <br />20. ALL NEW MATERIAL SHALL HAVE A U.L LABEL. <br />21. CONDUIT ROUGH—IN SHALL BE COORDINATED WITH THE MECHANICAL EOUIPMENT <br />TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTR4CTOR AND <br />COMPLY AS REQUIRED. <br />22. ALL PANEL OIRECTORIES SHALL BE NPEWRITfEN NOT HAND WRITfEN. <br />23. INSTALL AN EQUIPMENT GROUNDING CON�UCTOR IN ALL CONDUITS PER THE <br />SPECIFICATIONS AND NEC. THE EOUIPMENT GROUNDING CONDUCTORS SHALL BE <br />BONDED AT ALL JUNCTION BOxES. PULIBOxES, AND ALL DISCONNECT SWITCHES, <br />STARTERS, AND EQUIPMENT CABINETS. <br />24. THE CONTRACTOR SHALL PREPARE AS—BUILT DRAWINGS. DOCUMENT ANY AND ALL <br />WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS <br />CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. <br />25. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE <br />PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES INDICATING EQUIPMENT <br />CONTROLLED, BRANCH CIRWITS INSTALLED ON, AND PANEL FlELD LOCATIONS FED <br />FROM (NO E%CEPTIONS.) PROVIDE SAMPLE FOR CONSTRUCTION MANAGER'S <br />APPROVAL. <br />26. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY <br />WITH (ADA) AMERICANS WITH DISABILITIES ACT AS ADOPTED BY THE APPLICABLE <br />STATE. <br />27. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROl1GH <br />BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION <br />MANAGERS APPROVAL SLEEVES ANO/OR PENETRATIONS IN FIRE RATED <br />CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL <br />MAINTAW THE FIRE RATING OF THE WALL OR STRUCNRE. fILL FOR FLOOR <br />PENEfRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. <br />ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. <br />28. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EJ(ISTING) SHALL BE <br />FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER <br />PRIOR TO ROUGH—IN Of CONDUIT AND WIRE ALL EQUIPMENT SHALL BE <br />PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE <br />N�FORMANIONTAT THEGTIME�FOFH�ESIGN ANDASOMEAEQUIPM NT CHARACTERSTICS NOTES <br />MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). <br />29. LOCATION OF ALL OUTLET, BOXES, ETC., AND THE IYPE OF CONNECTION (PLUG <br />OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO <br />70 EXISTI�G UTILIN POWER <br />SOURCE <br />CLCCTRICAL NOTGS � ] <br />GENERAL CONTRACTOR TO CHECK REQUIREMENTS WITH LOCAL POWER COMPANY AND <br />JURISDICTION. ADDITIONAL SUB PANEL OFF THE PPC CABWEf MIGHT BE REQUIRED TO FEED <br />NEW NEfWORK VISION EQUIPMENT. <br />EXISTING 200A <br />METER/DISCONNECi SWITCH <br />200A 2 . <br />/\ <br />M 3 <br />EXISTWG SERVICE GROUN� J <br />CIRCUIT SCHEDULE <br />NO FROM TO CONPiGURATiON <br />O1 SOURCE METER CENTER EXISTING <br />2 METER DSC TRANSPER SWITCH & EXISTING <br />O � LOAD CENTER <br />TRANSFER SWITCH & GENERATOR <br />OO LOAD CENTER RECEPTICLE EXISTING <br />TRANSFER & LOAD NEW MM85 CABMET (3) b2 AWG, (1) j�8 GND IN <br />O CENTER SUB—PANEL 2" CONDUIT <br />TRANSFER & LOAD NEW BBU CABINET (3) �10 AWG, (1) �10 GND IN <br />O CENTER SUB—PANEL 1" CONDUIT <br />EXISTING LOADS (REFER TO <br />PANEL SCHEDULE <br />22"x34" SCALE NOT TO SCALE <br />11"x17" SCALE NOT TO SCALE <br />iHE INFORMA710N CONTAWED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN TNAT WHICH RELATES TO <br />ELECTRICAL PANEL SCHC��ULE I 2 <br />E%ISTING 200A GENERATOR <br />RECEPTACLE <br />TRANSFER SWITCH & LOAD <br />CENTER <br />SERVICES IS STRICTLY PROHIBITED <br />EL[CTRICAL ONE-LINE I�IAGRAM � 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.