1. ALL �ETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALIATION <br />AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. <br />2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER <br />METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO <br />SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS <br />MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. <br />GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR <br />� POLE USING MFR'S PR4CTICES. <br />NEW SPRINT ANTENNA � 3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. ALL WIRES <br />MOUNTING PIPE � SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHAL� BE <br />CONNECTED W EXiSTING � � GREEN INSULATED WIRE ABOVE GROUND. <br />ANTENNA G�ROUND BAR � <br />4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. <br />^ / GROUNDING AND OTHER OPERATIONAL TESTING WIL� BE WITNESSED <br />/ � BY SPRINT WIRELESS, LLC. REPRESENTATIVE. <br />/ \ NEW SPRiNT RRU 5. REFER TO DIVISION i6 GENERAL ELECTRIC; GENERAL ELECTRICAL <br />� � / yC� CONNECTED TO EXISTING PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING <br />ANTENNA GROUND BAR STANDARDS. <br />NEW SPRINT ANTENNA MOUNTING <br />� PIPE CONNECTED TO EXISTiNG 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF <br />ANTENNA GROUND BAR GROUNDWG SYSTEM PER SPRINT STANDARD GROUNDING METHOD, <br />(�� AND RECENE APPROVAL OF DESIGN BY AUTHORIZED SPRINT <br />NEW SPRINT RRU � I EXISTING SPRINT ANTENNA GROUND 6 MOBILITY REPRESEMATIVE, PRIOR TO INSTALLATION OF GROUNDING <br />CONNECTED TO EXISTING / BAR (3 TOTAL, 1 PER SECTORj E-� SYSTEM. PHOTO DOCUMENT ALL EXOTHERMIC AND GROUND RING <br />ANTENNA GROUND BAR <br />/ � 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES <br />CONNECTION FROM EXISTING SPRWT ANTENNA � -P�� INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. <br />GROUND BARS TO EXISTING MASTER GROUND BAR � <br />� 8. ALL EXISTING GROUND BARS, WIRES & CONNECTIONS SHALL BE <br />�g EXISTING SPRINT MASTER MGB FIELD VERIFIED. ANY DERCIENT ITEMS SHALL BE REPLACED AS <br />E_� GROUND BAR AT UPPER —.�j__.__ REQUIRED TO ACMEVE ADEOUATE GROUNDING REQUIRED BY SPRINT. <br />TOWER & GROUND LEVEL <br />EXISTING FINAL GROUND LEAD FROM MASTER CONNECTiON FROM NEW <br />cRouNo enR To ExisTiNc MONOPo�E / � saRiNT cPs To ExisTiNc GCNCRAL GROUNDING NOTGS <br />GROUND BAR � GROUND LEVEL MASTER GROUND BAR <br />\ \ GROUNDING NOTES <br />1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID COPPER <br />NEW SPRINT AMENNA MOUNTING CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED <br />PIPE CONNECTED TO EXISTiNG �� GROUNDING RING AND PROVIDE PARA�LEL EXOTHERMIC WELD. <br />ANTENNA GROUND BAR <br />L E G E N D NEW SPRINi RRU �s.s• 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BEfWEEN <br />CONNECTED TO EXiSTING EACH SECTION AND LP,BEL EACH SECTION ("P", "A", "N", "I") WITH <br />■ EXOTHERMIC CONNECTION 1" HIGH LETTERS. <br />ANTENNA GROUN� BAR <br />TRUE I��MAGNETC <br />D MECHANICAL CONNECTION r+onm / Norrrn 3. ALL HARDWARE 18-8 STAINLESS STEEL, INCLUDING LOCK <br />fF WASHERS, COAT ALl SURFACES WITH AN ANTI-OXIDANT COMPOUND <br />o COMPRESSION CONNECTION / �� BEFORE MATING. ALL HARDWARE SHALI BE STAINLESS STEEL 3/S <br />INCH DIAMETER OR L4RGER. <br />CGB COLLECiOR GROUND BAR ��. =`- {�� <br />4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT <br />MG9 EXTERNAL GROUND BAR ��� � WASHER BEfWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN <br />ANTI-0%IDANT COMPOUND BEFORE MATING. <br />5. NUT & WASHER SHALL BE PLP.CED ON THE FRONT SIDE OF THE <br />GROUNDING BAR AND BOLTED ON THE BACK SIDE. INSTAL� BLACK <br />22"x34" SCALE: 1" = 1'-0" HEAT-SHRINKWG TUBE, 600 VOLT INSULATION ON ALL GROUNDWG <br />11"xV" SCA!E: 1/7' = 1'-0" �' 6" 0" 1' ANT�NNA GROUN��ING I�LAN 1 TERMINATIONS. THE WTENT IS TO WEATNERPROOF THE <br />COMPRESSION CONNECTION. <br />6. NUMBER OF GROUNDING BARS MAY VARY DEPENOING ON THE <br />NPE OF TOWER, ANTENNA LOCATION, AND CONNECTION <br />ORIENTATION. PROVIDE AS REpUIRED. <br />7. GROUNDING KIT SHALL BE NPE AND PART NUMBER AS SUPPLIED <br />OR RECOMMENDED BY CABLE MANUFACTURER. <br />8. WEATHERPROOFlNG SHALL BE TYPE AND PART NUMBER AS <br />SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. <br />._.'__ i� I 9. SUPPLIED AND INSTALLED BY CONTR4CTOR. <br />....._..._ _.__._ i..__ _� ____.. <br />I `" i I I � I 10. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A <br />I GROUNDING BAR TO AN EXISTIN6 TOWER, THE SUBCONTRACTOR <br />I _I I SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO <br />I�, I MOUNTING THE GROUNDING BAR TO THE TOWER. <br />� __ � j � �- - -� I <br />1L EXTEND TWO (2) 2 AWG TINNED CU CONDUCTOR FROM BURIED <br />I I j ! I GROUNDING RING AND CONNECT TO THE NEW TOWER. FOLLOW <br />! MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS <br />I I I� I TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY.) <br />I� I I II 12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE <br />TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION <br />I I I I ORIENTATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR <br />INSTALLING ADDITIONAL GROUNDING BARS AS REOUIRED, PROVIDING <br />50% SPARE CONNECTION POINTS. <br />IEXISTING FINAL GROUND <br />EXISTING FINAL GROUND I � - I I 13. EXPOSED GROUND WIRES TO BE NON METALLIC LIQUID TIGHT. <br />LEAD FROM MASTER �� I LEAD FROM MASTER , <br />GROUND BAR TO � GROUND BAR TO <br />EXISTING EOUIPMENT I i' EXISTING EQUIPMENT I �i I <br />GROUND RING <br />I � �� i GROUND RING tn I I I <br />m I m i <br />�9 EXISTING SPRINT I /� II i I ' I 9 EXISTING SPRINT <br />E_7 MASiER GROUND BAR E-7 MASTER GROUND BAR I/I '. I <br />� � � i, \ � � <br />T � <br />NEW SPRINT MM85 I \�I �\1 I NEW SPRINT MMBS �I I\\�— I I <br />CONNECTED TO ' <br />CONNECTED TO \ i EXISTING SPRINT � � I <br />EXiSTWG SPRiNT O 'I MASTER GROUN� BAR I I �= l- I <br />MASTER GROUND BAR 1 <br />NEW SPRINT BBU CONNECTED TO I I �-" — —t ' NEW SPRINT BBU CONNECTED TO � <br />I ,� � � tsS EXISTING SPRWT MASTER GROBAR � I � . �65� <br />EXISTING SPRINT MASTER GROUND I I . I <br />BAR -- � � ; L�p_'___..�-- _. I � <br />�- -----------� � _------ --- --- <br />TRUE IMGNETIC TRUE �AUGNEiIC <br />NORTH NORTH NONTH � NORlH <br />� -� i � <br />.. ���. <br />> <br />� �� �,�,i <br />zz�`34� S�"`E: ,i4•• _,�-°�� EQUIPMENT GROUNDING PLAN (INTERIM) 2, 2z'�x3'�• S�A�E: ,i'• _,�-°•• EQUI['MENT GROUNDING I'LAN (fINAL) 3 <br />11"xi7" SCALE: 7/8" = 1'-0" 4' 3' 7 1' 0" 4' 11"x17" SCALE 1/B" = t'-0" 4' 3' 7 1' 0" 4' <br />THE INFORMATION CONTAWED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITE�. <br />