Laserfiche WebLink
r <br />A & E Insulation, Inc. <br />15205 39th Avenue NE <br />Marysville, WA 98271 <br />Office: (360) 651-1058 Fax: (360) 651-1259 <br />Website: www.aeinsulatian.com <br />Date:12/5/13 <br />Builder or Owner Mustach Development, LLC <br />House address or lot #: 3313 Nassau Street, Everett, WA 98201 <br />Ring (if applicable): Open A' B <br />Air Leakage Testing (Blower poor TestJ <br />Conditioned Floor Area: �-,�C��� Calculated Volume (Cubic Feet <br />Ceilin� Hei�ht <br />Standard <br /><_5.0 ACHso <br />(,CFMSoX 60) / Conditioned Volume) <br />Si�;nature %%� <br />�. I' i � S I <br />Tested CFMso <br />Gl��ssary <br />Pascal (pa): Unit of pressure <br />CF�1: Conditioned floor area in square feet <br />��� i�_��- <br />Test Result (ACHso) <br />�F����y; ��,�hi� f�nt N��i fii;;;,,,7,� :�f Uif icaiia�C �� 5v pascais af pr2ssure <br />Total Leakage: Aggregation of the entire systems duct leakage in a duct test. <br />Coriditioned Volume: Volume of conditioned space (CFA X ceiling hieght) <br />ACI-Iso: Air changes per hour at 50 pascals of pressure <br />Air Leakage Testing Code Language <br />R�G02.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not <br />exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 <br />Pa�scals). Where required by the code official, testing shal/ be conducted by an approved third party. A written report <br />of the results of the test shall be siqned by ihe party conducting rhe test and provided to the code official. Testing <br />shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual <br />in:spection has confirmed sealing (see Table R402.4.1.1), operable windows and doors manufacrured by small business <br />shall be permitted to be sealed off at the frame prior to the test. Durinq testinq: <br />1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br />weatherstripping or other infiltration control measures; <br />2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond <br />intended infiltration control measures; <br />3. Interior doors, if installed at the time of the test, shall be open, access hatches to conditioned crawl spaces and <br />conditioned attics shall be open; <br />4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br />5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and <br />6. Supply and return registers, if installed at the time of the test, shall be fully open. <br />HVAC ducts supply and return registers shall not be sealed. <br />