My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1526 OAKES AVE 2016-10-12
>
Address Records
>
OAKES AVE
>
1526
>
1526 OAKES AVE 2016-10-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 1:37:53 AM
Creation date
10/4/2016 8:35:48 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1526
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />� Botesch, Nash 8F Hall <br />Architects, P.S. <br />May 2, 2013 <br />ATTN: Jeff Heilman <br />City of Everett <br />RE: Carson House <br />1526 Oakes Avenue <br />Plan Check No: C1303-010 <br />Architectural Comments: <br />• <br />€ . __ .. s <br />� � ,� r . n;� <br />��� i����7���.1���ii�� a <br />�� � � � � <br />;� � <br />;a=..��.�� ��)ti'�` 0 2 2013 d �-%/� <br />� <br />�� <br />� C'i�'p' �...��' w 'ir�:F��i::�� �" � <br />��....�:.....�t,.��l;�iy)�� �.�a�5�"�I�i.�eJ e <br />... _ .,,...........�,�,... ,.,.�.. Yl�.--_....e,..�,..a..-a.-�.,� <br />-� 1. Cementitious skirting panels are not rated for structural resistance to wind <br />and seismic loading. Provide detail of approved material to resist wind and <br />seismic loading. <br />I����,� Sheet AF1.0 — Revised detail 2 to show 5/8" sheathing. See attached <br />Structural response letter. <br />'�IX p��� <br />Wb a/ 2. Note on drawing "50% of all luminaries shall be high efficacv luminaries" per <br />WA State Energy Code (WSEC). <br />Sheet A1.0 — ADD GENERAL NOTE: "ELECTRICAL — 50% OF ALL <br />LUMINARIES SHALL BE HIGH EFFICACY LUMINARIES" <br />��1►�' 3. Specify how minimum prescriptive design requirements for whole house <br />�pp� ventilation system is provided. Each dwelling shall be equipped with a <br />� S ventilation system complying with Section M1508.4, M1508.5, M1508.6 or <br />( N� M 1508.7. Specify . <br />Sheet A1.0 — REVISE KEYNOTE #1.7 TO READ: "GAS FORCED AIR <br />FURNACE. CONTRACTOR TO VERIFY THAT A MINIMUM OUTSIDE AIR <br />FLOW RATE OF 113CFM IS PROVIDED IN ACCORDANCE WITH WHOLE <br />HOUSE VENTILATION CALCULATION ON SHEET G1.0. INTERMITTANT <br />WHOLE HOUSE VENTILATION INTEGRATED WITH FORCED AIR SYSTEM <br />TO COMPLY WITH SECTION M1508.5". <br />4. Provide roof framing plan. Show location of all girder trusses and show how <br />point loads are provided with support to the foundation. <br />y�. <br />
The URL can be used to link to this page
Your browser does not support the video tag.