Laserfiche WebLink
PRE-FABIlf TED BUILDING DESIGN - FOUNDATILCULATIONS <br /> BRIGGS ENGIN "MIG PO BOX 140537, GARDEN CITY, ID 8 ;' 537 IBC-2012 <br /> CLIENT Pacific Mobile DEALER: Pacific Mobile Criteria 25psf-RLL,40psf FLL,110mph, Exp <br /> C, Cat-D, Ss=1.5, Fp=1500 psf <br /> Date: 22-Feb-17 EST#PO# E17040 Location: KCDA Standards <br /> 28x32 MODULAR COPYRIGHT WA West <br /> Project#: 201701 1WC-1 05.1W1 FDN-Classroom w/(2) BEI 2017 State(s): Cascades PNW <br /> Floor Joist Spans <br /> I.DESIGN CRITERIA: 28x32 MODULAR FDN-Classroom w/2 Floor Joist S•ans/Module <br /> Dead Load: Roof, RDL= 10 psf <br /> 1st Floor Ceiling CDL= 1 <br /> E&M= 1 <br /> Floor, FDL= 10 psf <br /> Wall,WDL= 9 psf <br /> Roof Live Load: Snow Load, RLL= 25 psf <br /> Load Duration Factor, Cd= 1.15 % <br /> Floor Load: Uniform Floor Load, FLL= Classroom 40 psf IBC Table 1607.1 <br /> Concentrated Live Load, p= 1000 lbs. IBC Table 1607.1 <br /> Partion, PDL= 0 psf <br /> Wind Load: Basic Wind Speed,V= 110 mph ASCE 7 Figure 26.5-1A <br /> Building Risk Classification: Category II ASCE 7 Table 1.5-1 <br /> Wind Importance Factor, Iw= 1.00 ASCE 7 Table 1.5-1 <br /> Wind Directional Factor, Kd 0.85 ASCE 7 Table 26.6-1 <br /> "a" Edge Pressure Distance= 3.00 ft <br /> 3 Roof Slope= 3 :12= 14.04 Degrees <br /> Edge Wind Pressure,Wep= 24.1 psf ASCE 7 Figure 28.6-1 <br /> Interior Wind Pressure,Wip= 16 psf ASCE 7 Figure 28.6-1 <br /> Average Wind Pressure, Wp= 17.74 psf ASCE 7 Figure 28.6-1 <br /> Exposure Category= C Exposure Factor, A= 1.21 ASCE 7 Figure 28.6-1 <br /> Wind Topographic Factor, Kz= 1.00 ASCE 7 Section 6.5 <br /> Design Wind Pressure, Pw=Wp*A*Iw*Kz= 18.2 psf IBC Section 1605.3.1 <br /> Average Uplift Wind Pressure, Wup= -19.6 psf <br /> Seismic: Upper Modue Weight= 0.00 psf <br /> Base Module Weight= 27.79 psf <br /> Total Weight,Wtot= 27.79 psf <br /> Snow Load % Used in Seismic Design = 0% <br /> Soil Site Class D <br /> Seismic Category= D PNW IBC Table 1613.3(1) <br /> Mapped Spectral Accelerations, short periods, Ss= 1.5000 IBC Figure 1615 <br /> Site Coefficient, Fa= 1.00 IBC Table 1615.1.2(1) <br /> Max. Spectral Response, SMS= Fa*Ss= 1.50 IBC Equation 16-16 <br /> Design Spectral Response, Sos=2/3*SMs= 1.00 IBC Equation 16-18 <br /> Response Modification Coefficient, R= 4.00 IBC Table 1617.6 <br /> Lateral Load Factor, F=(1,Single Story; 1.1, 2-story; 1.2, 3-story) 1 ASCE 7-05, 12.14.8.1 <br /> Total Shear,pst=F*SDS*Wtot/R= 6.95 psf ASCE 7-05 Equation 12.14.11 <br /> Dimensions: Nominal Module Length, ML= 32 ft. <br /> Nominal Module Width, MW= 14.00 ft. <br /> Width,W= #Units= 2 28.00 ft. <br /> Length, L= #Units= 1 32.00 ft. <br /> 1st Floor Wall Ht. = 9.00 ft. <br /> 2nd Flr.Wall Height, Wht= 0.00 ft. <br /> Roof Height, Rht= 3 :12 Slope 3.50 ft. <br /> Floor Height above NG, Fht= 30 inches 2.50 ft <br /> Building Ht Coeff, Htc= Rht+Wht+Fht-10 1.00 <br /> No. of floor spans per module, nfs= 2 <br /> Clear Distance between supports, L2a= 84.00 inches <br /> 2/4 201701.05,KCDA STD FDN-Calcs PRINTED-2/22/2017 <br />