• <br />u <br />7. Specify size �3nd location of whole house fan as required by Section M1508 IRC and <br />Table M1508.2 or calculate size per the equation specified in Section M1508.3 for <br />intermittentl,y operating ventilation systems. <br />8. Specify on p'lans'�A minimum of 50% of all luminaires shall be high efficacy luminaires" <br />per Section a05.1 Washington State Energy Code. <br />9. Provide plans, sections and details for exterior deck and stair construction, including <br />guards, handrail, rise, run, baluster material and spacing, ledger attachment and <br />landings. <br />10. Ramps shall comply with Section R311.8. Show requirements on plans. Ramps shall be <br />not less than 36" wide. <br />11. Show how ��welling is heated per Section R303.8 IRC. <br />12. Verify minimum ceiling height of 7'0" is provided in all habitable rooms per Section <br />R305.1 IRC. Bedroom #1 does not appear to provide the minimum required ceiling <br />height. <br />13. The new door on the south side of the 1� floor requires a landing or a floor on both <br />sides. Shaw floor and landing as required per Section R311.3 IRC. <br />14. All e�erioi�� wall cavities that are exposed during construction shall be insulated to the <br />maximum depth of the framing cavity without compressing the insulation. Walls that <br />were cove:red shall be exposed for inspection of all components including insulation, <br />piumbing, mechanical, framing and electrical. <br />15. All plumbing including groundwork, shall be inspected before being covered. <br />16. Include plans, sections and details as needed for all proposed repairs to the existing <br />detached garage. <br />Please preparE a response letter showing where each item in this correction letter is <br />addressed on i:he plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required suC�mittals shall be of sufficient detail and contain sufficient information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />�o �,�;���____ <br />� <br />Jeff Heilman <br />Development T"echnician <br />425-257-8976 <br />Email: 'he� ilmar�@ci.everett.wa.us <br />S:\1Common\Clerical\JHeilman\CW1212-001 (2132 Rockefeller).doc <br />