My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10415 ROSEWOOD AVE ABSOLUTE COMFORT 2019-05-07
>
Address Records
>
ROSEWOOD AVE
>
10415
>
ABSOLUTE COMFORT
>
10415 ROSEWOOD AVE ABSOLUTE COMFORT 2019-05-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2019 9:34:33 AM
Creation date
10/4/2016 2:30:59 PM
Metadata
Fields
Template:
Address Document
Street Name
ROSEWOOD AVE
Street Number
10415
Tenant Name
ABSOLUTE COMFORT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> 4/4/2016 <br /> 2 <br /> 6. Detail 4 shows rigid insulation (R-Value not defined) on the interior of the <br /> foundation stem wall. R-21 insulation is required for that condition, R-21 will not fit into a <br /> 2x4 cavity. <br /> �'�� �'-�Z� <br /> The existing wall extension shows on detail 3/AD 1. The existing 2x4 <br /> wall become to 2x6 after install addition sister studs. So R-21 will be <br /> installed properly. <br /> 7. R-10 rigid insulation is required under the perimeter of a slab -on-grade when the <br /> slab is within 24" of the finished grade. <br /> The detail modified and 24" length of rigid insulation under existing <br /> slab provided <br /> 8. A minimum of 75% of permanently installed lamps in lighting fixtures shall be <br /> high-Efficacy lamps (R404.1 WSEC). Provide note on drawings. <br /> The note provided on sheet A04 <br /> 9. Section AA shows the exterior wall with studs extending from the new ceiling <br /> down to the slab-on-grade. Detail 4 shows the same studs stopping at the top of the <br /> concrete wall with wedge bolts that don't appear to be going through either of the 2x4 <br /> plates shown. <br /> Partial section A-A revised. <br /> 10. Detail 1 doesn't appear to occur anywhere on the drawings <br /> Typo con-ected <br /> 11. The floor plan shows a reference to detail 10 on sheet S1 that does not exist. <br /> Typo corrected <br /> 12. Note on drawings "all groundwork plumbing to be inspected before covering". <br /> The note provided on sheet A04 <br /> 13. R-4 pipe insulation is required on all hot water in conditioned and no conditioned <br /> spaces. Note on plans <br /> The note provided on sheet A04 <br /> 14. All additions to existing building that are less than 750 square feet <br /> of heated floor area shall specify 0.5 Credits for Additional energy <br /> archstudioyshadyrya2016 <br /> ��� <br />
The URL can be used to link to this page
Your browser does not support the video tag.