Laserfiche WebLink
PV ARRAY INFORMATION 3-STRINGS(12,9,9)IT-285 <br /> (+) MODULES IN SERIES (-) <br /> #OF MODULES IN BRANCH:12,9,9 r- ---------------------------------------------------------- <br /> ------- -- -- <br /> #OF PARALLEL BRANCHES:3 <br /> EXTREME LOWEST TEMP:14 F <br /> HIGHEST AVERAGE TEMP:93 F <br /> PV MODULE RATINGS(a)STC <br /> --------- -----------------------------------------------------------------' <br /> MODULE MANUFACTURER:iTek <br /> MODULE MODEL:71 -285 <br /> OPEN CIRCUIT VOLTAGE:39.2 V <br /> SHORT CIRCUIT CURRENT:9.4 A <br /> MAX SERIES FUSE(OCPD):15 A #6 ECG/GEC <br /> MAXIMUM POWER VOLTAGE:32.3 V <br /> MAXIMUM POWER:285 Wp <br /> Solar Panels and Inverters are <br /> manufactured in Washington <br /> INVERTER RATINGS i (6)#10 AWG Wire State by iTek Energy. <br /> INVERTER MAKE:SOLECTRIA and(1)#6 AWG<50 <br /> INVERTER MODEL:PVI 7600-TL ft to main service <br /> MAX PV VOLTAGE(OC)=600 v panel in 1 inch EMT <br /> MAX PV CURRENT(IC)=20A(per tracker) i (V_d=0.29%) <br /> PHOTOVOLTAIC POINT OF <br /> MAX POWER V c=sW INTERCONNECTION SIGN: <br /> NOMINAL AC VOLTAGE <br /> =2TAGE=240 V i 69 . <br /> MAX AC CURRENT=31.7 A <br /> (SOURCE SIGN ON AC DISCONNECT) <br /> PHOTOVOLTAIC ARRAY Integrated DC RATED POWER STC=8.55 kW <br /> CHARACTERISTICS SIGN: Disconnect SYSTEM AC VOLTAGE=240 Vac <br /> i <br /> SYSTEM AC CURRENT=40 A <br /> 690.53 PHOTOVOLTAIC POWER Inverter <br /> (SOURCE SIGN ON DC DISCONNECT) <br /> RATED POWER=8.55 kW <br /> RATED CURRENT=26.1 A f/ <br /> RATED VOLTAGE=324V <br /> MAX SYSTEM VOLTAGE=437 V <br /> MAX SYSTEM CURRENT=35.25 AAD <br /> --------------- --------- ----- <br /> Distance from production meter is> 1 ft <br /> and<6 ft from the net meter To Utility <br /> (3)#8 AWG Wire and i PV output LINE <br /> (1)#6 AWG>50 ft to i Meter 200-AMP Main <br /> main service panel in i Service Panel Net Meter <br /> %inch EMT <br /> (V d=0.4%) i-------- 40A-2Pole <br /> 60 AMP AC Breaker LOAD <br /> Disconnect Main OCP <br /> I <br /> ' LINE <br /> i <br /> 7 <br /> i <br /> LOAD <br /> #6 ECG/GEC <br /> ------------------ ----- ---- --- ------- DRAWN BY: DATE <br /> AM 6/2/16 Eros Residence <br /> 32201st Ave.So.#800 PV ELECTRIC PLAN <br /> Seattle,WA 98134 <br /> SIZE FCSM NO. DWG.N0. REV <br /> NOTES: <br /> S JERRA g <br /> MAX SYSTEM VOLTAGE_(Voc)x(#Modules in Series)x(Temp.Factor=1.12) S Y S T E M S <br /> MAX SYSTEM CURRENT=(Isc)x(#STRINGS)x(125%) SUN 4 CARnI ENCRGY SOLUTIONS SCALE SHEET <br /> DC VOLTAGE LINE LOSS=I_op x(R_c/1000)x L/V-op x 100% o.800.865.9005 NTS <br /> AC VOLTAGE LINE LOSS=2 x I_op x(R_c/1000)x L/V op x 100% f. 800.865.0045 <br />