� <br />� <br />3.7.2 Basic Structural Checklist for Building Type W2: Wood Frames, Commercial And <br />Industrial <br />This Basic Structural Checklist shall be completed when required by Table 3-2. <br />Each of the evaluation statements on this checklist shall be marked Compliant (C), Non-Compliant <br />(NC), or Not Applicable (N/A) for a Tier 1 Evaluation. Compliant statements identify issues tha.t are <br />acceptable according to the criteria of this standard, while non-coinpliant statements identify issues that <br />require further investigation. Certain statements may not apply to the buildings being evaluated. For <br />non-compliant evaluation statements, the design professional may choose to conduct further <br />investigation using the corresponding Tier 2 evaluation procedure; the corresponding section numbers <br />are in parentheses following each evaluation statement. <br />C3.7.2 Basic Structural Checklist for Building Type W2 <br />These buildings are commercial or industrial buildings with a floor area of 5,000 square i:eet or <br />more. There are few, if any, interior walls. The floor and roof framing consists of wood or steel <br />trusses, glulam or steel beams, and wood posts or steel columns. Lateral forces are resisted by wood <br />diaphragms and exterior stud walls sheathed with plywood, oriented strand board, stucco, plaster, <br />straight or diagonal wood sheathing, or braced with rod bracing. Wall openings for storefronts and <br />garages, where present, are framed by post and beam framing. <br />Building System <br />NC LOAD PATH: The structure shall contain one complete load path Y<>r Life Safety and <br />Immediate Occupancy for seismic force effects from any horizontal direction that serves to <br />transfer the inertial forces from the mass to the foundation. (Tier 2: Sec. 4.3.1.1) <br />Shear walls are supported on wood beums and posts at crawl space. There is no mech�utism to <br />transfer shear forces to fo«nctations. <br />N/A MEZZAN[NES: Interior mezzanine levels shall be braced independently from the main <br />structure, or shall be anchored to the latcral-force-resisting elements of the main structure. <br />(Tier 2: Sec. 43.13) <br />No mezzanines. <br />N/A WEAK STORY: The strength of the lateral-force-resisting system in any story shall nor, be less <br />than 80 percent of the strength in an adjacent story, above or below, for Life-Safety and <br />Immediate Occupancy. (Tier 2: Sec. 4.3.2.1) <br />Single Story building. <br />N/A SOFT STORY: The stiffness of the latcral-force-resisting system in any story shall not be less <br />than 70 percent of the stiffness in an adjacent story, above or below or less than 80 percent of <br />the average lateral-force-resisting system stiffness of the three stories above or below for Life- <br />Safety and Immediate Occupancy. (Tier 2: Sec. 4.3.2.2) <br />Single Story building. <br />N/A GEOMETRY: There shall be no changcs in horizontal dimension of the lateral-force-resisting <br />system of more than 30 percent in a story relative to adjacent storics for Life Safety and <br />[mmcdiate Occupancy, excluding one-story penthouses or mezzanines. (Tier 2: Sec. 4.3.2.3) <br />ASCE 31-03 Seismic Evaluation of Existing Buildings Basic Structural Checklist for W2 <br />