My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6301 36TH AVE W 2016-11-01
>
Address Records
>
36TH AVE W
>
6301
>
6301 36TH AVE W 2016-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2017 3:54:49 PM
Creation date
10/24/2016 11:19:27 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6301
Notes
GEOTECHNICAL REPORT INCLUDED
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
diagrams must match installation plans and load calculations. Components must be listed <br /> and approved for use together. Changes to,plans must include new drawings and <br /> calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Engineering&Public Services Department <br /> electrical permit must be present for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering& <br /> Public Services Department. Electrical inspections and approval are required prior to <br /> calling for acceptance tests. Call (425)257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for <br /> postponing Fire Department inspection and testing and shall result in denial of <br /> occupancy. <br /> 12. Fire Sup ressionSprinkler) Sstem-An approved automatic suppression system shall <br /> be provided as required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett <br /> Municipal Code. The system must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering&Public Services <br /> Department for examination and approval. Such plans shall include plans for the <br /> underground mains that will supply the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may <br /> be an NFPA 13,NFPA 13R, or NFPA 13D system depending upon several factors. <br /> Sprinkler installation shall not begin without an approved and stamped set of plans <br /> from the Engineering&Public Services Department. The Fire Department will also <br /> review the plans and shall field inspect the installation based only on approved plans that <br /> must be on site. Changes to plans must be approved by both the Engineering&Public <br /> Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br /> Standard 13. Underground piping shall be hydrostatically tested and flushed as <br /> established in NFPA Standard 24 for private fire mains. (Below-ground piping must be <br /> installed by Washington State Patrol Licensed Underground Sprinkler line certified <br /> "U" installers. For further information, contact the State Fire Marshal's Office at <br /> (360)570-3134 or contact the Everett Fire Department at(425)257-8124.) All such <br /> tests shall be witnessed by a Fire Department Inspector. Call(425)257-8126 to make an <br /> appointment for inspection. <br /> Contractors'materials and test certificates shall be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call (425)257-8124 for more information. <br /> 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.