Laserfiche WebLink
Component Performance • • I Zones • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Powder Mill - Bldg A Date 06/18/2014 <br /> Occupancy Group Q Commercial Q Group R For Building Department Use <br /> Change in occupancy or space conditioning Q <br /> Note-Proposed UA may exceed Target UA by 10%per C101.4.4 and C101.4.5 <br /> Fenestration Area as%gross above-grade wall area 12.2% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 1.ids Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:U-factors shall come from Appendix A, Chapter C303,or calculated per approved method as specified in C402.1.2. <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor,page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> Y <br /> R=30 ID:Min.rigid above roof 0.032 107444 3438.2 0.034 107444 3653.1 <br /> m R= ID: Above Deck Insulation U-0.034 <br /> R= ID: <br /> a R= ID: 0.031 <br /> 0 00 R= ID: Metal Building U-0.031 <br /> of R= ID: <br /> R= ID: 0.021 <br /> t R= ID: Single raft,attic,other U-0.021 <br /> O R= ID: <br /> j� R= ID: 0.055 <br /> 1 R= ID: Steel/metal frame U-0.055 <br /> R= ID: <br /> o a R= ID: 0.052 <br /> 07 R= ID: Metal Building U-0.052 <br /> 2i R= ID: <br /> CE <br /> R= ID: 0.054 <br /> n 0 R= ID: Wood Frame,other U-0.054 <br /> C0 <br /> CU <br /> R= ID: <br /> O <br /> R=21 ID:6"metal,24"oc,air gap 0.090 40587 3652.8 0.104 40587 4221.0 <br /> N <br /> In R= ID:or R-11 stickpins Mass Wall U-0.104 <br /> 7i R= ID: <br /> R= ID: 0.104 <br /> FU <br /> o 3: R= ID: Assumed to be Mass Wall U-0.104 <br /> Z a <br /> m R= ID: <br /> (7 R= ID: <br /> N R= ID: 0.031 <br /> In R= ID: Mass Floor U-0.031 <br /> U) <br /> R= ID: <br /> ti R=21 ID:Metal studs 0.110 360 39.6 0.029 360 10.4 <br /> E R= ID: Joist/Framing U-0.029 <br /> LL R= ID: <br /> F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= ID:No insulation 0.730 1918 1400.1 0.540 1918 1035.7 <br /> Co @c R= ID: Slab-On-Grade U-0.54 <br /> c <br /> R= ID: <br /> C'77 <br /> R= ID: 0.550 <br /> c R= ID: Heated Slab-On-Grade U-0.55 <br /> = R= ID: <br /> *Proposed non-residential CMU walls meeting Table C402.1.2 Area UA Area UA <br /> Footnote D requirements can use the target U value of 0.104 rather Page 1 <br /> than Appendix A values.Show footnote requirements in plans. Subtotal 150309 8531 L150309 8920 <br /> Component Performance Compliance (UA) UA COMPLIES1 ozlllb <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 <br />