My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6301 36TH AVE W 2016-11-01
>
Address Records
>
36TH AVE W
>
6301
>
6301 36TH AVE W 2016-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2017 3:54:49 PM
Creation date
10/24/2016 11:19:27 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6301
Notes
GEOTECHNICAL REPORT INCLUDED
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • A MIA• <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Powder Mill - Bldg A Date 06/18/2014 <br /> Fenestration Area as%gross above-grade wall area 12.2% Max.Target: 30% For Building Department Use <br /> Skylight Area as%gross roof area 1.1% Max.Target: 5% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes. 1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Provide NFRC rated SHGC or default from Table C303.1.3(3)for fenestration assembly SHGC. <br /> 4-Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> space shall be included in this worksheet. <br /> Skylights Proposed SHGC Target SHGC <br /> Provide source of SHGC,page/plan#of assembly detail&ID SHGC x Area(A) =SHGC x I SHGC x Area(A)= SHGC x A <br /> ID:Bristolite Energy Star,double dome fiberglass 0.46 1216 559 0.35 1216 425.6 <br /> ID: SHGC 0.35 <br /> ID: <br /> ID: <br /> ID: <br /> Totals 1216.0 559.4 Totals 1216.0 425.6 <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assembly PF SHGC' x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID:NFRC 0 0.35 6216 2176 PF<0.2 0.40 6216 2486.4 <br /> ID: 0 0.25PF<0. 0.48 <br /> ID: 0 PF>:0.5 0.64 <br /> ID: 0 ++If projection factor(PF)credits are <br /> ID: o applied to the proposed design, Target <br /> ID: 0 SHGC will sum fenestration area by PF <br /> ID: 0 <br /> category. <br /> ID: 0 <br /> ID: 0 <br /> ID: 0 <br /> +If projection factor credit is applied,then vertical Totals 6216.0 2175.6 Totals 6216.0 2486.4 <br /> fenestration must be entered in the correct table according <br /> to orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> *Note.Fenestration that separates conditioned space from <br /> a non-conditioned or semi-conditioned space shall be listed <br /> here with a proposed SHGC equal to the target value. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assembly PF SHGC' x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 PF<0.2 0.40 <br /> ID: 0 0.25PF<0. 0.44 <br /> ID: 0 PF>_0.5 0.48 <br /> ID: 0 ++If projection factor(PF)credits are applied <br /> ID: 0 to the proposed design, Target SHGC will <br /> ID: 0 sum fenestration area by PF category. <br /> ID: 0 <br /> North Total <br /> Area ISHGCxA Area I SHGC x A <br /> To comply,the Proposed total SHGC x A for all fenestration Grand Grand <br /> (vertical&skylights)shall not exceed the Target total SHGC x A. Total 7432.0 2735.0 Total 7432.0 2912.0 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 <br />
The URL can be used to link to this page
Your browser does not support the video tag.