My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6301 36TH AVE W 2016-11-01
>
Address Records
>
36TH AVE W
>
6301
>
6301 36TH AVE W 2016-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2017 3:54:49 PM
Creation date
10/24/2016 11:19:27 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6301
Notes
GEOTECHNICAL REPORT INCLUDED
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Powder Mill - Bldg B Date 06/18/2014 <br /> Occupancy Group Q Commercial O Group R For Building Department Use <br /> Change in occupancy or space conditioning Q <br /> Note-Proposed UA may exceed Target UA by 10%per C101.4.4 and C101.4.5 <br /> Fenestration Area as%gross above-grade wall area 8.4% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 1.1% Max.Target: 5.0SS <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:U-factors shall come from Appendix A, Chapter C303,or calculated per approved method as specified in C402.1.2. <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor,page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> y R=30 ID:Min.rigid above roof 0.032 117865 3771.7 0.034 117865 4007.4 <br /> a R= ID: Above Deck Insulation U-0.034 <br /> 0 <br /> R= ID: <br /> N a R= ID: 0.031 <br /> o m R= ID: Metal Building U-0.031 <br /> R= ID: <br /> R= ID: 0.021 <br /> R= ID: Single raft,attic,other U-0.021 <br /> O R= ID: <br /> E R= ID: 0.055 <br /> 11 R= ID: Steel/metal frame U-0.055 <br /> R= ID: <br /> ' 0.052 <br /> o a R= ID: <br /> Q m R= ID: Metal Building U-0.052 <br /> N 5 R= ID: <br /> R= ID: 0.054 <br /> o R= ID: Wood Frame,other U-0.054 <br /> C) <br /> CU <br /> n �: R= ID: <br /> O <br /> IR=21 ID:6"metal,24"oc,air gap 0.090 43483 3913.5 0.104 43483 4522.2 <br /> N <br /> @ R= ID:or R-11 stickpins Mass Wall U-0.104 <br /> R= ID: <br /> R= ID: 0.104 <br /> m <br /> o 3: R= ID: Assumed to be Mass Wall U-0.104 <br /> � (D <br /> m � R= ID: <br /> c7 R= ID: <br /> N R= ID: 0.031 <br /> m R= ID: Mass Floor U-0.031 <br /> `No R= ID: <br /> LL (D R=21 ID:Metal studs 0.110 245 27.0 0.029 245 7.1 <br /> E R= ID: Joist/Framing U-0.029 <br /> LL R= ID: <br /> F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= ID:No insulation 0.730 1778 1297.9 0.540 1778 960.1 <br /> CU R= ID: Slab-On-Grade U-0.54 <br /> � R= ID: <br /> ami R= ID: 0.550 <br /> ca -Z6 <br /> R= ID: Heated Slab-On-Grade U-0.55 <br /> = R= ID: <br /> 'Proposed non-residential CMU walls meeting Table C402.1.2 Area UA Area UA <br /> Footnote D requirements can use the target U-value of 0.104 rather Page 1 <br /> than Appendix A values_Show footnote requirements in plans. Subtotal F1633711 9010 L163371 9497 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> � b <br /> Franklin Engineering 1 625 4th Ave Ste 202 1 Kirkland, WA 98033 �Z I <br />