Laserfiche WebLink
� <br />� <br />COMPANV PROJECT <br />Design Build Services, Inc. A and S Construction <br />-'� �OO � Wo r k s� 28119 120th St SE 2102 Wetmore Ave, Everett <br />Monroe, WA 98272 Steve Findley <br />(360) 793-9659 b1l.wwb <br />somvaee rou woov �srcN Juty 25, 2012 1731 <br />Design Check Calculation Sheet <br />WoodWorks Sizer 9.15 <br />Loads: <br />Load Type Distribution Pat- Location [ft] Magr,itude Unit <br />tern Start End Start End <br />1_j13 Dead Partial UDL 0.06 1.56 55.7 55.7 plf <br />2_j13 Live Partial UDL 0.06 1.56 160.0 160.0 plf <br />3_j19 Dead Partial UDL 0.06 1.56 62.7 62.7 plf <br />n j14 Live Partial UDL 0.06 L 56 160.0 180.0 plf <br />5_j15 Dead Partial UDL 1.56 13.56 62.7 62.7 plf <br />6_j15 Live Partial UDL 1.56 13.56 180.0 180.0 plf <br />7_j16 Dead Partial UDL 1.56 13.56 212.6 212.6 plf <br />8_j16 Live Partial UDL 1.56 13.56 220.0 220.0 plf <br />9 b13 Dead Point 1.56 46� lbs <br />10 b13 Live Point 1.56 139 lbs <br />11 b13 Snow Point 1.56 51 lb& <br />Self-wei ht Dead Full UI7L 13.3 lf <br />Maximum Reactions (Ibs) and Bearing Lengths (in) : <br />� - - - - - - 13'-7.3" -� <br />13�_6�. <br />Unfactored: <br />Dead 2141 1987 <br />Live 2739 2710 <br />Snow 45 6 <br />Factored: <br />Total 4880 4698 <br />Eearing: <br />Length 1.37 1.31 <br />Min re 'd 1.37 1.31 <br />b11 <br />Glulam-Unbal., West Species, 24F-V4 DF, 5-1/2"x10-1/2" <br />Supports: All - Timber-soft Column, D.Fir-L No2 <br />Tola I I en gth : 13'-7.3"; <br />Lateral support: top= full, bottom= at supports; <br />Analysis vs. Allowable Stress (psi) and Deflection (in) using NOS 2005 : <br />Criterion Anal sis value Desi n value Anal sis/Desi n <br />Shear fv = ll5 Fv� = 265 fv Fv� = 0.43 <br />Hending(�) fb = 1902 Fb' = 2400 fb/Fb' = 0.79 <br />Dead Defl�n 0.24 = L/685 <br />Live Defl'n 0.32 = L/512 0.95 = L/360 0.70 <br />Total Defl�n 0.67 = L/241 0.68 = L/240 0.99 <br />Additional Data: <br />FACTORS: F/E(psi)CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# <br />Fv' 265 1.00 1.00 1.00 - - - - 1.00 1.00 1.00 2 <br />Fb'i 2400 1.00 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2 <br />Fcp' 650 - 1.00 1.00 - - - - 1.Oo - - - <br />E' 1.8 million 1.00 1.00 - - - - 1.00 - - 2 <br />Emin� 0.85 million 1.00 1.00 - - - - 1.00 - - Z <br />CRITICAL LOAD COMBINATIONS: <br />Shear : LC #2 = D+L, V= 4880, V design = 4439 lbs <br />Bending(.): LC #2 = D+L, M= 16022 lbs-ft <br />Deflection: LC #Z = D+L (live) <br />LC #2 = D+L (total) <br />D=dead L=1ive 5=snow w=wind I=impact Lr=roof live Lc=concentrated E=earthquake <br />All LC's are listed in the Analysis output <br />Load combinations: ASCE 7-OS / IBC 2009 <br />CALCULATIONS: <br />Deflection: EI = 955e06 lb-in2 <br />"Live" deflectior. _ �eflection from all non-dead loads (l.ive, wind, snew...; <br />Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. <br />Design Notes: <br />t. WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2009), lhe National Design Specifcation (NDS 2005), and NDS Design Supplement. <br />2. Please verify that the default deflection limits are appropriate for your application. <br />3. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSIlAITC A190.1-1992 <br />4. GLULAM: bxd = actual breadth x actual depth. <br />5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. <br />6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). <br />