6305 36TH AVE W B 2016-10-31
>
Address Records
>
36TH AVE W
>
6305
>
6305 36TH AVE W B 2016-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2021 3:57:30 PM
Creation date
10/31/2016 4:06:57 PM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6305
Unit
B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • - WAT7TV11r • <br /> If vertical fenestration area exceeds maximum allowed per Section C402.3.1d <br /> ,then Target Area Adjustment of all applicable envelope elements is require <br /> This worksheet automaticallycalculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in <br /> this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and EN V-SHG C forms. <br /> VF=Vertical fenestration NW=Net above grade w all(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade <br /> Proposed Areas <br /> Vertical Fenestration-> VF= 4292.0 <br /> Opaque- NW= 43483.0 DR= 3279.0 <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen.Area <br /> 51054.0 X 30.0% - 100 = 15316.2 <br /> total Vertical Delta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 4292.0 - 15316.2 = -11024.2 II greater <br /> -11024.2 <br /> Multiplier applied to all <br /> Total Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> 4292.0 - = 4292.0 - 4292.0 = 1.00 calculate Target Vertical <br /> Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Milt. Multiplier applied to all <br /> 43483.0 = 43483.0 - 43483.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> U A Adjustments calculate TargetAb ove- <br /> Grade Wall Area <br /> Vertical Fenestration Proposed Area Target VF Muft. Target Area <br /> Non-metal frame X = <br /> Metal f ra me,fixed 4187.0 X 1.00 = 4187.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door 105.0 X 1.00 = 105.0 Targetareas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are appliedto <br /> Steel FrameX = target areas on ENV-UA <br /> Metal Building = <br /> Wood/Other frame X = <br /> Mass 43483.0 X 1.00 = 43483.0 <br /> Sum of target above-grade <br /> Sum of Proposed 47775.0 Sum of Target 47775.0 wall and vertical <br /> fenestration areas are <br /> calculated to equal the <br /> SHGC x AAdjustments sumofproposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Muft. Target Area <br /> PF<0.2 4292.0 X 1.00 = 4292.0 <br /> 0.2:5PF<0.5 X = <br /> PF>-0.5 X = SHG C target areas in <br /> North Vertical Fenestration shadedboxes are applied <br /> to target areas on ENV- <br /> PF<02 X = SHGC <br /> 0.2:s PF<0.5 X = <br /> PF>_0.5 X = <br /> C <br /> Franklin Engineering 625 4th Ave Ste 202 Kirkland, WA 98033 <br />
The URL can be used to link to this page
Your browser does not support the video tag.