Kasch Park Soccer Fields Addendum No. 01 <br /> Synthetic Turf Replacement Phase 2 March 1, 2016 <br /> with a megohm meter at 500 volts. The Contractor shall provide a written report of <br /> the results of his testing to the Engineer prior to installation of the new floodlight <br /> poles. A reading in excess of two (2) megohms shall be deemed satisfactory for <br /> retention of the existing circuit wiring. <br /> 2.5 Section 32 18 23 Infilled Synthetic <br /> MODIFY Section 1.01 A.8 to read as follows: <br /> 8. Installation of field underlayment/supplemental pad system, consisting of <br /> either a 23 mm polypropylene panel or a 25 mm paved in place Elastic Layer <br /> Pad. <br /> 2.6 Section 32 18 23 Infilled Synthetic Turf <br /> MODIFY Section 1.03 Synthetic Turf Surfacing to read as follows: <br /> A. The following vendors and corresponding products are pre-approved for the Synthetic <br /> Turf Field surface: <br /> 1. Greenfields(503) 367-7365 <br /> 2.6 Section 32 18 23 Infilled Synthetic Turf <br /> MODIFY Section 2.03 A to read as follows: <br /> A. The supplemental pad system shall be either an interlocking polypropylene panels or a <br /> paved in place elastic layer pad. The shock-absorbing pad shall become part of the <br /> base for the synthetic turf surfacing system. <br /> 2.7 Section 32 18 23 Infilled Synthetic Turf <br /> ADD Section 2.03 C as follows: <br /> C. Polyurethane Elastic Layer Pad <br /> 1. The shock-absorbing pad shall be a paved-in-place (in-situ) porous elastic <br /> layer and shall become part of the base for the system. <br /> 2. The elastic layer shall be porous and shall resist the effects of adhesives, <br /> water,freeze-thaw, heavy loads associated with athletic fields, <br /> compression/deflection, rot, mold, mildew, bacteria, and air-borne pollution. <br /> 2 <br />