Laserfiche WebLink
�� ': <br />� : .� . <br />t ),C•i <br />q ` �: 3� <br />.e .. <br />� <br />uponor <br />Oct. 29, 2012 <br />To Whom It May Concern: <br />Continuous lengths of Uponor AquaPEX° and Wirsbo hePEXT"" crosslinked polyethylene (PEX-a) tubing offer the <br />greatest system integrity, and their use is the normal practice for in-slab or under-siab instaliations. However, <br />in certain situations, Uponor recognizes splices or joints in Uponor AquaPEX and Wirsbo hePEX rnay be <br />necessary for tube installed in or under a concrete slab. In such instances, it is important the installer uses the <br />proper fitting for the application and observes proper installation techniques. Below is a list of fittings most <br />commonly used with Uponor AquaPEX and Wirsbo hePEX tubing, along with a brief overview of their <br />appropriate usage and limitations. <br />• ProPEX° engineered polymer (EP) fittings (tees, elbows, couplings or plugs) are the most versatile <br />fittings and can be buried directly in the soil, in or under a concrete slab in both exterior and interior <br />applications, or in concealed or accessible spaces. <br />• ProPEX lead-free (LF) brass fittings (tees, elbows, couplings or adapters) may be buried directly in the <br />soil, under a slab in both exterior and interior applications, or in concealed or accessible spaces. Note <br />that fittings buried directly in concrete must be completely wrapped with a piece of flexible insulation <br />or similar isolating material. <br />• ProPEX yellow brass fittings (tees, elbows, couplings or adapters) for installations in non-potable water <br />applications may be used in concealed or accessible locations, but must be completely wrapped with a <br />piece of flexible insulation or simiiar isolating material if buried in or under a slab in both exterior and <br />interior applications. <br />Additiona{ly, PEX tubing for potable hot- and cold-Niater distribution is approved for installation directly within <br />or below concrete slabs, provided the application of any required pesticide/termiticide treatment is done <br />according to recommendations. The PEX tubing is not required to be sleeved; however, Uponor's installation <br />instructions recommend using either flexible polyethylene (PE) protection sleeves or rigid PVC bend guides at <br />all s�ab penetrations to protect the PEX tubing from abrasion. <br />When using Uponor's pre-sleeved tubing products or a protedion sleeve around the tubing, an annuiar gap <br />between the protection device and the PEX tubing will exist. In such installations, the installer must fill the <br />annutar gap between the protection device and the PEX tubing at the exposed ends to prevent pathways for <br />pests and the mistaken application of harmful chemicals into this space. The following sealants may be used <br />with Uponor PEX tubing provided the sealant manufacturer has approved its use far contact with PEX. <br />• Latex caulk <br />• Latex foam <br />- Silicone sealant <br />• Polyurethane expanding foam <br />Provided the above requirements are followed, the applicable Uponor warranty will remain in effect for the <br />PEX tubing and ProPEX fittings. For 1`urther yuestions, please refer to the Uponor Compfete Design Assistance <br />Manual (CDAM), Che Plumbing Design Assistance Manual (PDAM) or contact Uponor'iechnical Services at <br />888.594.7726 or technical.services uqonor com. <br />Sincerely, <br />Dale E. Stroud <br />Senior Director, Offerings/Marketing <br />Uponor Nor[h America <br />Uponor, Inc. <br />5925 148�" Street West <br />Apple Valley, MN 55124 <br />Tel: (800) 321-4739 <br />Fax: (952) 891-2008 <br />Web: www,uponor-usa.com <br />Uponor Ltd. <br />2000 Argentia Road <br />Plaza 1, Suite 200 <br />Mississauga, pN L5N iWl <br />Tel: (888) 994-7726 <br />Fax: (800) 638-9517 <br />Web: www.uponor.ca <br />�' <br />aF a <br />,, �a. <br />