'�Simale Heatina Svstem Size: Washinaton State <br />The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br />0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br />Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, <br />some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension <br />Program at (360) 956-2042 for assistance. <br />Project Information Contact Information <br />Unit E3 Townhome Polygon Northwest <br />5ilver Lal<e Tovmhomes Alaina RoberCson <br />Everett, Washin ton (425) 606-0005 <br />HedilllQ SySte171 TVI�e: OO Forced Air Furnace Q Heat Pump <br />To see detailed instructions for each section, p/ace your cursor on the word "Insfructions". <br />Desiqn Temperature <br />�cu4ru�iior�s _. �__ —, Design Temperature Difference (�T) <br />k EVerelt JC �� � 4T = fndoor (70 degrees) - Ouldoor Design Temp <br />1....i-��,ii____'��3��� ...._.__,..�., ) <br />Area of Buildinq <br />Conditioned Floor Area <br />er,s�� uctions Conditioned Floor Area (sq ft) <br />Average Ceiling HeighY <br />if5L1 "��iO1J Average Ceiling Height (ft) <br />Glazinq and Doors <br />inskruc!ians <br />Insulation <br />Attic <br />I,�struc�ioz; — - j <br />� R-�i9 � j <br />Single Rafter or Joist VaWted Ceilings <br />fnsfratctsorrs ..-- � - -:_ ..._ � <br />� No Vaultetl Cellinps In this proJect <br />t -- — � _ ��� <br />Above Grade Walls �:ee Fre�re y� <br />Instructions , -- — � <br />� ��. R-21 . .. � � <br />�--,�— µ---�-�-� " `r - - <br />Floors <br />_. _ _ .... _ <br />Instructions -- —, I <br />�R-3D � . .:. � " �f <br />_ _ - --- P-- - ,: <br />_. _..�,.... .��-.....:...,��,� ,_ :,.-, - <br />Below Grade Walls �see Fre�.e r� <br />_ ___ ___.____ __._ <br />bistructions i . _. _ ,.__ _--- � <br />No Bebw Gratle Walls m(hls pro�ect � <br />�._----*— - - <br />Slab Below Grade rsee Fi4�.e n <br />,. .._., .,, . tJo Slab Below Grade in this project. �' I <br />i ... �..a�:...� �.-r..:^�,. 1 <br />Slab on Grade �see Fiaure n <br />�nstructions _: __ _..:. -.---- . .�:_:: _.:__— I <br />!t R-10 Perimeter '�' <br />Location of Ducts <br />if75ifUCi:011': .-..- ... . _. _ ... f <br />t Contlluoned Space � '+ J <br />�,��.�. - �.��r - �...,.1 <br />Fiqure 1. <br />`� ��.. <br />,-. �.Y-� - -,—�-_.— -" <br />I�. __I <br />Ahove Grade �I <br />-; <br />. � -- 8elawGrade � � � --- • <br />1,585 <br />Conditioned Volume <br />8.5 13,473 <br />U-Factor X Area = UA <br />0.30 269 80.70 <br />U-Factor X Area = UA <br />0.026 263 6.84 <br />U-Factor <br />U-Factor <br />0.056 <br />U-Factor <br />0.029 <br />U-Factor <br />F-Factor <br />Area <br />� <br />Area <br />528 <br />Area <br />379 <br />Area <br />0 <br />Length <br />� <br />UA <br />UA <br />29.57 <br />UA <br />10.99 <br />UA <br />UA <br />F-Factor Len th UA <br />0.540 81 43.88 <br />Duct Leakage Coefficient <br />1.00 <br />Sum of UA <br />171.97 <br />�f� <br />Envelope Heat Load 8,083 Btu / Hour <br />sum or un xer <br />Air Leakage Heat Load 6,839 Btu / Hour <br />Vo/umeX O.6XOTX.018 <br />Building Design Heat Load 14,921 Btu / Hour <br />Air Leakage + Envelope Heaf Loss <br />Building and Duct Heat Load 14,921 Btu / Hour <br />Ducts in unconditioned space: Sum of 8uilding Heaf Loss X 1.10 <br />Ducts in conditioned space: Sum o/ Building Heet Loss X 1 <br />Maximum Heat Equipment Output 20,890 Btu / Hour <br />Build/ng and Duct Heaf Loss X 1.40 lor Forced Air Fumace <br />Bwlding and Duct Heat Loss X 1.25 tor Hea! Pump <br />(07'01/13) <br />