Laserfiche WebLink
� � � I � � � � • � <br />2009 Washinaton State Enerav Code Comoliance Forms for Nonresidentiai and Multifamily Residential Revised February 2011 <br />Project Address Rick Steves xr Date 06/07/2013 <br />Occupancy Group � Nonresidential � Multifamily residential Clear For Building Department Use <br />Climate Zone OO Zone 1 O zone 2 <br />Fenestration Area as % gross exterior wall area 18 . 5� Max. Target: 40 . 0$ <br />Notes: 1: If fenestration area exceeds maximum allowed, then calculate adjusted areas on Target Area <br />Adjustment sheet on the backside of the ENV-SHGC form. <br />2: U-factors shall come from chapter 10 or calculated per 1332. <br />See the ENV-CHK worksheet for example of how to complete the rows on this form. <br />Building Component Proposed UA Target UA <br />Provide assembly ID & page/plan # for each bldg. element U-factor x Area (A) = UA (U x A U-factor x Area (A) = UA (U x A) <br />R= ID: 0.034 � <br />Y <br />� R= ID: Above Deck Insulation U-0.034 <br />0 <br />R= ID: <br />a R= ID: 0.031 I <br />o°� R= ID: Metal Building U-0.031 <br />� � R= ID: <br />� R= 38 ID: Batts over ceilings 0. 027 68a ie . s o. 02� 684 ie . 5 <br />� R= ID: Single raft, attic, other U-0.027 <br />� R= ID: <br />� R= ID: 0.064 <br />� R= ID: Steel frame/metal bldg U-0.064 <br />� R= ID: <br />> � R= ID: <br />0 <br />Q s R=21 ID: 2X6 Wd, 24"oC, R21 0.051 586 29.9 0.057 I 586 I 33.4 <br />�, a R= ID: Wood Frame, other U-0.057 <br />� a R= ID: <br />� � R= ID: <br />s R= 15 ID: 2x4 Wd, 24"oc, R15 0. 072 211 15 .2 0. 150 211 I 31 . 7 <br />m <br />� N R= ID: Mass Wall U-0.150 <br />m R= ID: <br />� R= ID: <br />Proposed assembly U-factor from Tables 10-5 thru 10-5B <br />N R= ID: 0.150 I <br />o� R= ID: Assumed to be Mass Wall U-0.150 <br />m � R= I D: <br />� Proposed assembly U-factor from Tables 10-5 thru 10-5B. Do NOT use Table 10-1. <br />� N U=0.5 ID: WOOd 0.500 42 21.0 0.60 42 25.2 <br />n a U= ID: All Doors U-0.60 <br />O � U= ID: <br />� <br />R= ID: �•a2g � I <br />$ R= ID: Floors U-0.029 <br />�` R= ID: <br />F-factor x Perimeter �= UA(U x A) F-factor x Perimeter = UA (U x A) <br />� R= ID: NO InSUlatlOn 0.730 103 75.2 0.540 103 I 55. 6 <br />� L R= ID: Slab-On-Grade U-0.540 <br />� � R= ID: <br />� � R= ID: 0.360 <br />� <br />�� R= ID: Heated Slab-On-Grade U-0.360 <br />= Proposed assembly F-factors can use the unheated values in Table 10-2 <br />� ne 1 CMU �v�lls meetin�Table 13-1 �o tno�e 1 c� be entered � Area UA � � Area UA <br />�*nt�iU value o 15 rather an Table 1 5� va ues. ans must pa e 1 <br />clearly state footnote requirements. g 1626 160 1626 164 <br />Subtotal <br />Continue on to back of form <br />