Laserfiche WebLink
2009 Washingtor - � Energy Code Compliance Forms for Nonresid� and Multifamily <br />2009 Washin ton State Ener Code Com liance Forms for Nonresidential and Multifamil Residential Revised February2011 <br />Project Address Rick steves xr Date 06/07/2013 <br />If the total fenestration area as a% of gross exterior wall area (calculated on ENV-SUM) exceeds the maximum allowed in Table � 3-1, <br />then this calculation must be submitted Use the resulting areas in the Target UA and SHGC calculations above. <br />SKY= Skylight. Refered to as overhead glazing in WSEC 1333 & � 334 and equations 13-1 & 13-2. <br />VF = vertical fenestration. Refered to as vertical glazing in WSEC 1333 & 1334 and equations 13-1 & 13-2. <br />NW = net wall (excludes fenestration, BG, and doors.) DBG = Doors and below grade wall. <br />Total Fenestration = SKY + VF. Gross Exterior Wall Area= VF + NW + DBG <br />Proposed Areas <br />Above Grade Walls Doors & BG Walls <br />Fenestration -> SKY= VF- 191 . 0 0 <br />Opaque -> NW= 797 . 0 DBG= 42 . 0 <br />Gross Exterior Max Fenestration % Maximum Target <br />Wall Area (Table 13-� ) Fenestration Area <br />1030.0 X 40.0� — �OO = 412.0 <br />i <br />Total Fenestration Maximum Target Excess Fenestration 0 Excess Fenestration <br />191 .0 — 412.0 = -221 .0 — �j lesser = <br />-221.0 <br />Total Fenestration Excess Fenestration Target Fenestration Total Fenestration Target VF Multiplier Apply to all Proposed <br />191.0 — = 191 . 0 — 191 . 0 = 1. 00 Fenestration Areas to get <br />Target Fenestration Area <br />Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Apply to all Proposed <br />797.0 + = 797 . 0 — 797 . 0 = 1. 00 Opaque AG Wall Areas to <br />get Target Area <br />Vertical Fenestration Proposed Area Target VF Mult. Target Area <br />metal frame 138 . 0 X 1. 00 = 138. 0 <br />non-metal frame 32 . 0 X 1. 00 = 32 . 0 <br />metal entrance 21 . 0 X 1. 00 = 21 . 0 <br />Skylight Proposed Area Target VF Mult. Target Area <br />without curb X = B Target areas in shaded <br />boxes shall be used as <br />with curb X target areas on ENV-UA. <br />AG Wall Proposed Area Target Net Wall Mult. Target Area <br />Steel Frame/metal X — <br />Wood/Other frame 586. 0 X 1. 00 = 586. 0 <br />Mass 211.0 X 1.00 = 211.0 <br />Sum of Proposed 988 . 0 Sum of Target 988. 0 Sum of Proposed must <br />equal Sum of Target. <br />SHGC Calculation Proposed Area Target VF Mult. Target Area <br />Skylights (all) X = SHGC target areas in <br />shaded boxes shall be <br />Non-North Vertical Fenestration X — entered as target areas <br />North Vertical Fenestration X = on ENV-SHGC <br />Franklin Engineering � 625 4th Ave Ste 202 � Kirkland, WA 98033 <br />