2009 Washington State E�y Code Compliance Form for Nonresidential
<br />2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential
<br />Multifamilv Residential
<br />Revised November 2010
<br />Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage Q Other
<br />Qualification Checklist Lighting � Check if 95% or more of fixtures compiv with 1,2 or 3 and rest are ballasted.
<br />Note: If occupancy type is "Other" and fixture Fixtures:
<br />Section 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) refiector or louvers,
<br />answer is checked, the number of fixtures in � c) 5-60 watt T-1, T-2, T-4, T-5, T-8, or CFL lamps, and d) hard-wired eleCtroniC
<br />the space is not limited by Code. Clearly 1521)
<br />indicate these spaces on plans. If not dimming ballasts. Screw-in CFL fixtures and tracking lighting do not qualify.
<br />qualified, do �PA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps <=150w c) electronic ballasts
<br />3. LED lights.
<br />TABLE 15-1 Unit Lighting Power Allowance (LPA)
<br />Use LPA (W/ft Use LPA W/ft )
<br />Automotive facility 0.85 Office buildings, office/administrative areas in facilities 0.91
<br />of other use types (including but not limited to schools,
<br />hos itals, institutions, museums, banks, churches S
<br />Convention center 1.10 Parkin ara es 0.20
<br />Courthouse 1.10 Penitentia and other Grou I-3 Occupancies 0.90
<br />Cafeterias, fast food establishments , 1.20 Police and fire stations 0.90
<br />restaurants/bars5
<br />Dormitor 0.85 Post office 1.00
<br />Dweling Units 1.00 Retail , retail banking, mall concourses, wholesale 1.33
<br />stores (pallet rack shelvin )
<br />Exercise center 0.95 School buildings (Group E Occupancy only), school 1.00
<br />classrooms, da care centers
<br />G mnasia, assembl spaces 0.95 Theater, motion picture 0.97
<br />Health care clinic 1.00 Theater, erformin arts 1.25
<br />Hospital, nursing homes, and other Group I-1 and 1.20 Transportation 0.80
<br />I-2 Occu ancies
<br />Hotel/motel 1.00 Warehouses 0.50
<br />Laboratory spaces (all spaces not classified 1.62 Workshops 1.20
<br />"laboratory" shall meet office and other appropriate
<br />cate ories
<br />Laundries 1.20
<br />Libraries 1.20 Plans Submitted for Common Areas Only
<br />Manufacturin facilit 1.20 Main floor buildin lobbies (except mall concourses) 1.10
<br />Museum 1.00 Common areas, corridors, toilet facilities and 0.80
<br />washrooms, elevator lobbies
<br />Footnotes for Table 15-1
<br />1)
<br />2)
<br />3)
<br />4)
<br />5)
<br />6)
<br />7)
<br />8)
<br />9)
<br />10)
<br />��
<br />In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
<br />specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
<br />comparable use specified in the table. See Section 1512 for exempt areas.
<br />The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by
<br />subsequentfootnotes.
<br />Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet.
<br />For all other spaces, such as seating and common areas, use the Unit Light Power Ailowance for assembly.
<br />Watts per square foot of room may be increased by 2°/o per foot of ceiling height above 9 feet.
<br />Reserved.
<br />For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used.
<br />Reserved.
<br />For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting PowerAllowance for the court area is
<br />2.60 W/ftZ.
<br />Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
<br />walls or at least three-quarter-height partitions (transparent or opaque) and lighting for free-standing display where the lighting moves
<br />with the display are exempt.
<br />An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically
<br />designed and directed to highlight merchandise. The following additional wattages apply:
<br />i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below;
<br />ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or
<br />iii. 2.5 watts per square foot of jewelry, crystal or china floor area.
<br />The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans.
<br />Calculate the additional power ailowance by multiplying the above LPDs by the sales floor area for each department excluding major
<br />circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional
<br />1,000 watts for each separate tenant larger than 250 square feet in area.
<br />The additional wattage is allowed only if the merchandise display luminaires comply with all of the following:
<br />(a) Located on ceiling-mounted track or directly on or recessed into the ceiling itself (not on the wall).
<br />(b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two
<br />points of track attachment).
<br />This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general
<br />lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be
<br />used for any other purpose.
<br />This additional lighting power is allowed only if the lighting is actually installed.
<br />Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
<br />computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
<br />..i 1L... .....I... TL... L...�..MI ..II ............. ..I..F.....J �.. f....1....�.. '] ......I:.... ....1., 1.. 11... FI..... ....... ....a .....,......,1 L.�. .....I...