, � � <br /> /�/BL/C N/O/�X5 i <br /> July 25, 2002 <br /> Alex Leighton <br /> 19900— l44'" Avenue NE I <br /> Woodinville, WA 98072 <br /> RE: Owner: Delta Properties <br /> Job Address: 10411 Airport Road <br /> Plan Check No: 60207-029 <br /> Dear Mr. Leighton: <br /> In response to your application for a construction permit, your plans have bee . Axamined and you are <br /> advised that the issuance of a permit is being withheld for the reasons listed beluw. These comments <br /> address buil�ing issues only. Additional revisions, or addi[ions, may be required by other <br /> depaRments (such as Utilities, Planning or Fire). All references refer to the 1997 Uniform Building <br /> Code, as amended by the State of Washington and/or Washing[on State Energy Code, 2001 Edition, <br /> unless stated otherwise. <br /> In order for the Qrocessing of your application to rnntinue, it will be necessary to provide the <br /> Building Division with two complete new sets of drawings reflecting the corrr.ctions requested. <br /> l. UBC Table SA requires the exterior bearing walls of the H-4 repair garage ta be of 4-hour <br /> fire-resistive construction. Please verify or revise. <br /> 2. UBC 1006.2.1 prohibits exit stairways in areas where openings are required to be protected <br /> by Table SA. Table SA would require any opening along the east wall to be protected. <br /> Therefore, the exit cannot occur along the east wall. Removal of this exit compromises tha <br /> exiting from the second floor. UBC 1004.2.2 prohibits exiting thr�ugh more than one <br /> intervening room. With the upstairs hallway considered an intervening room with a <br /> cumulative occupant load of more than 1Q the downstairs H-4 occupancy would then <br /> become a second intervening room. <br /> 3. In the H-4 cecupancy, mechanical ventilation should be provided capabie of exhausting a <br /> minimum of 1 cubic foot per minute per square foot of Floor area in accordance with Section <br /> 1202.4. <br /> 4. Please provide the necessary detailing ro ensure one-hour fire-resistive construction for all of <br /> the beams and columns that support the horizontal occupancy separation bet�rs�n the B and <br /> H-4 occupanci�es. UBC 302.2. <br /> 5. Since door number l36 is part of the B/H-4 occupancy separation, it is required to havz a <br /> one-hour rating. UBC 3023.4. <br /> OEDL➢LVCIGNSTRN11IlE0.�B]PI�209�ib1 I,�IRPOpT M1Di ,�L <br /> CITY OF EVERETT • 320C Cedar Streei • Everett. WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br />