Laserfiche WebLink
2006 Wa ' gton State Nonresidential Energy Code CompU^nce Form <br /> � . . <br /> 2006WwNM�m IaleNonwMnuYE^mYYCotleCu�ViianceFmn RSMse0JWY2001 <br /> PfOjBClAdd�B53 goo-Ll� S�cMlcal eki1L Cmt�c Building 1 R�M�lqn w� 9/16/]009 <br /> The tdlowing infortnatlon is neeessary lo chedc a mechanical permit applicatlon ta compliance wiM the mechanical requiremenfa in tlie <br /> W ashinglon State Nonresiden6al EnergY Cade. <br /> Applicability Code Location Buildi�g DepaAment <br /> (yes,no,n.a.) SecUon Canponent Informalion Required on Plans Notes <br /> HVAC REOUIREMENTS(Sections 1401-7424) <br /> 1N1 EQuipment psrfamanu <br /> .a. 1011.4 Pkg.elec.htg.8 Gg. Lisl�eat pumps on schedule <br /> y�s 1411.1 Minimum e(ficiency Epuipment schedule wiM rype,capacity,eifitiency x1.12 <br /> .a. 1611.1 CombusGon h�q. I�diwte intermittent igniNon,flue/draft damper 8 jackel bss <br /> 1412 HVAC conVols <br /> ya• 1412.1 Tempereture zones Indiwte locatlons on plans M4•'°� <br /> y�s /412.2 DeadbanC control Indicate 5 degree dead6an0 minimum 15970 <br /> .a. 7412.3 Humidity control Indicate�umidisWl <br /> yae 1412.4 Aulanatic setbadc Indicate thermosfat with night setback and 7 diN.day types � 15970 <br /> yes 1412.4.1 Dampers indicate damper location anC auto.conVols 8 maz.leakage KS.xx <br /> y.e 1412.42 Optimum Start Indicate optimum start controls 15970 <br /> .a. 1412.5 Heat WmD�� Intlicate microprocessar on Mermostat schedule <br /> .a. 1412.6 ComDusUon�tg. Indicale modulating or stageC conirol <br /> yea 1412.7 Balancing Indicate balancing teaWres an plans �•� <br /> 1412.8 Ventilation Contrd Intlicate demand control ventllation for highvccupancy areas xl.l� <br /> yae 1422 Themwstat inteAock Indicate thermostat inteAock on plans b�•'� <br /> yaa 1423 Economizers EQuipmentschedule Mi.12 <br /> 1473 Aireeonomizers <br /> yas 1413.1 Air Ecano Operalion Indicate 100%capabiliry on schedule xl.lZ <br /> .a. 1473.1 Wtr Econo Operetion Indicate 100°�capaeity at 45 degF db&40 deg F wb <br /> .a. 74132 Water Econo Doc Indicale Gg load 8 waler econoe&dg tower perfortnance <br /> .a. 1413.3 Integrated operation Indicate capability fw paAial coolin0 <br /> .a. 1413.4 Humidification Indicale direcl evap or fog atomization wl air econanizer <br /> 7414 DucNng systams <br /> yec 1414.1 Ductsealing Indiwtesealingnecessary 15e91 <br /> ysa 14142 Duct insulation Indicate R-value of insulatlon on duct 15290 <br /> yea 7475.1 Piping insuladon Indicate R-value of insulation on piping is]6i <br /> omp et on equ remenls <br /> yee 14162.1 Canmissioning Provide commissioning plan 1so55 <br /> yes 1416223 Sys.Bal 8 Func.Test Indicate air anC water system bafancing&functional testlng 15eso <br /> yaa 1416.2.4 Canmissioning Indicate O&M manuals,record drawings,stafl training 15055 <br /> ya� 74162.5 Comm.Report InAicate requiremenis fw prelim.&final commissioniny reporl 15055 <br /> .a. 1434 Separate air sys. Indicate separate systems on plans <br /> yss Meehaniql Oletetl and alta . quipmenl schedule with ly�s, ase <br /> Summary Form inpuVoutput,etficiency,efm.hp,econanizer A'rT� <br /> 8C IOIIS <br /> 1M0 Serviu WatN AtQ. <br /> yae 1441 Elec.water heater Indicate R-10 insulation under fank �•13 <br /> ys 1442 Shut-off contrds Indicate automatic shutoff 15970 <br /> y.. 1443 Pipe Insulation Indicate R-value of insulation on piping 15361 <br /> .a. 1452 Heat Pump COP Indicale minimum COP of 4.0 <br /> .a. 7452 Heater Etficiency InOicate pool healer efficienCy <br /> .a. 1453 Pool heater conUols Indiwte switch anE 65 degree contrd <br /> .a. 1454 Pool covers Indicate vapor retardanl cover <br /> .a. 1454 Poals 90+degrees IMicate R-12 pod eover . <br /> no is e rc e or any ques on, prov e ezp ana on: �� ' <br /> �' <br />