My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1926 112TH PL SE 2017-01-13
>
Address Records
>
112TH PL SE
>
1926
>
1926 112TH PL SE 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 4:59:53 PM
Creation date
11/30/2016 11:24:55 AM
Metadata
Fields
Template:
Address Document
Street Name
112TH PL SE
Street Number
1926
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T�bi� R402.1.1 Footnotes <br />For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. <br />a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is <br />less than the label or design thickness of the insulation, the compressed R-value of the insulation from <br />Appendix Table A101.4 shall not be less than the R-value specified in the table. <br />b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. <br />Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br />through 3 where the SHGC for such skylights does not exceed 0.30. <br />`"10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous <br />insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the <br />basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 <br />cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or <br />exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- <br />13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br />basement wall. <br />d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. <br />e There are no SHGC requirements in the Marine Zone. <br />t Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br />R301.1. <br />g Reserved. <br />h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 <br />cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent <br />or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in <br />the locations where structura► sheathing is used to maintain a consistent total sheathing thickness. <br />' The second R-value applies when more than half the insulation is on the interior of the mass wall. <br />' For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38. <br />k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a <br />minimum of R-10 insulation. <br />� Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation <br />requirement. <br />Table R402.1.3 Footnote <br />a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as <br />specified in Section R402.1.3. <br />i, <br />• <br />
The URL can be used to link to this page
Your browser does not support the video tag.