www.hilti.us Profis Anchor 2.6.5 <br /> Company: Page: 1 <br /> Specifier: Project: <br /> Address: Sub-Project I Pos.No.: <br /> Phone I Fax: Date: 6/14/2016 <br /> E-Mail: <br /> Specifier's comments: <br /> 1 Input data <br /> h., <br /> Anchor type and diameter: Kwik Bolt TZ-CS 1/2(3 1/4) <br /> Effective embedment depth: hef=3.250 in.,hnam=3.625 in. <br /> Material: Carbon Steel <br /> j Evaluation Service Report: ESR-1917 <br /> Issued I Valid: 2/22/2016 15/1/2017 <br /> Proof: Design method ACI 318/ACI 93 <br /> Stand-off installation: eb=0.000 in.(no stand-off);t=0.500 in. <br /> Anchor plate: Ix x ly x t=4.000 in.x 8.000 in.x 0.500 in.;(Recommended plate thickness:not calculated <br /> Profile: S shape(AISC);(L x W x T x FT)=3.000 in,x 2.330 in.x 0.170 in.x 0.260 in. <br /> Base material: cracked concrete,4000,f�=4000 psi;h=420.000 in. <br /> Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present <br /> edge reinforcement:none or<No.4 bar <br /> Seismic loads(cat.C,D,E,or F) no <br /> Geometry[in.]&Loading[lb,in.lb] <br /> Z � <br /> ur <br /> cn _ <br /> Y <br /> •? <br /> l <br /> n a <br /> a <br /> X <br /> I nput data and results must be checked for agreement with the existing conditions and for plausibility! <br /> PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br />