My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-08 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-08
>
3003 W CASINO RD BLDG 45-08 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 2:19:11 PM
Creation date
12/1/2016 11:07:31 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-08
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- . .- <br />a � „■ ... �i ,,� � t�� y �,, + ., . /�■ <br />AA�MAK(AA■ CiAMrM�� ANA ■��MAAI/I�A�� � � <br />' ��'G02 Nlashington Stat2 Plonresidential Energy Code Ccmpliance Forms Revised July 200 <br />;ProjectAddress ao��Pg r.�,=rA�� - ww�rn ana as-oe ��atz 4/12/2011 <br />' The following information is necessary to check a mechanical permit apolication for compliance with the mechanical requirements in the <br />, �/Vashington State Nonresidential Energy Code. <br />1 <br />!Applicabiliry Code Location Building Department <br />j(yes, no, n.a.) Section Component Information Required on Plans Notes <br />r __ <br />HVAC REQUIREMENTS (Sections 1401-1424) <br />1411 Equipment performance <br />yes 1411.4 Pkg. elec. htg.8� clg. List heat pumps on schedule M2 <br />yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency MZ <br />yes 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss MZ <br />1412 HVAC controls <br />yes 1412.1 Temperature zones Indicate locations on plans M5o3 <br />yes 1412.2 Deadband control Indicate 5 degree deadband minimum M5o3 <br />-�� 1412.3 Humidity control Indicate humidistat <br />yes 1412.4 Automatic setback Mdicate thermostat with night setback and 7 diff. day types rt5o3 <br />yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 233300 <br />yes 1412.4.2 Optimum Start Indicate optimum start controls 230900 <br />Yes 1412.5 Heat pump control Indicate microprocessor on therrnostat schedule 238135 <br />' YeS 1412.6 Combustion htg. Indicate modulating or staged control 2374i3 <br />yes 1412� Balancing Indicate balancing features on plans 230593 <br />1412.8 Ventilation ConVol Indicate demand ccntrol ventilatien for high-occupancy areas <br />yPs 1422 Thermostat interlock Indicate thermostat interlock on plans M503 <br />I YeS 1423 Economiz2rs Equipment schedule t-t503 <br />1413 Air econo�nizers <br />yes 1413 t Air Econo Operation Indicate 100% capability on schedule M5o3 <br />-- a� 1413.1 1/Vtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb <br />1 a. 1413.2 Water Econo Doc Indicate clg load & water econoe & cig tower performance <br />� <br />+ yes 1413.3 Integrated operation Indicate capability for partial cooling rt5o3 <br />� 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer <br />1414 Ducting systems <br />1414.1 Duct sealing Indicate sealing necessary 233131 <br />1414.2 Duct insulation Indicate R-value of insulation on duct 230�13 <br />1415.1 Piping insulation Indicate R-value of insulation on piping 220719 <br />� '1416 Completion Requirements <br />14162.1 Commissioninq Provide commissioning plan rt2 <br />S 1416.2.2-3 Sys.Bal & Func.Test Indirate air and water system balancing & functional testing 230593 <br />1416.2.4 Cemmissioning Indicate O&M manuals, record drawings. stafi training 220000 <br />� 14162.5 Ccmm Report Indica?e requirements for prelim. & final commissioning report M2 <br />^� a- 1434 Sepzrate air sys. indicata separat� systems on plans <br />I Mechanical Completed and attachad. Equipment schedule with types. <br />Summa.ry Form inpuUouiput, efflciency. cim. np. �r_,ncmizer <br />'SERVICE WATER �fEATING AND HEATED POOLS (Sections 'J440-1�54) <br />14a0 Service water htg. <br />'- a � 1441 Elec. �riarer heater <br />yes 1442 Shut-off controis <br />yes 1443 Pipe Insulation <br />yes 1452 Heat Pump COP <br />� a � 1452 Heater Efficiency <br />�. 3. 1453 Pool heater controis <br />i. a. 1454 Pool Covers <br />,. a. , 1 n5d Porls 90+ deg �ee <br />� <br />indicate R-10 insulation und�r :�nl�. <br />Indicate automatic shut-off M5o1 <br />Indicate R-value of insulatiert en pioing 270919 <br />i�dicate minimum COP of 4.0 238125 <br />indicate pool heater efficiency <br />Indicate switch and 65 degree contrel <br />Indicate vapor retardant cover <br />Indirate R 12 aeoi ,over <br />
The URL can be used to link to this page
Your browser does not support the video tag.