Laserfiche WebLink
• • • � • • � ' � • <br />20i2 Wasi�ington St3te Energy Code Compiiance Forms for Commercial Buildings including R2 & Ft3 over 3 s:ores and sU Ft1 Rev+sed Jar 2p'.� <br />Pro;ect Address 6807 EVERGREEN WAY EVERETT, WA 98203 Date 3/9/2015 <br />The following information is necessary to check a permit application for compliance �vith the lighting, motor, and transformer requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />Applicability Location in Building Deparimeni <br />(yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br />Provide fixture schedule with fixture types, lamps, ballasts, and <br />rated watts pe� fixture, <br />C405.5 1 _ _ _ <br />Identify spaces cligible for lighting pov�er exemption on pians <br />C405 5.1.1 Total connected and in compliance forms; <br />7[es C405 5.1.2 _ _ _.._ <br />C405.5.1 3 �nterior lighting power fdentify lighting equipment eligible for exemption in fixture <br />C405 5 t4 schedule and in compliance forms; <br />indicate that exempt lighting equipment is in addition to general <br />area lighting and is controlled independently <br />C405.4 Exit signs P�ovide exit sign types and rated watts per fxture in fixture <br />schedule (maximum 5 watts per fixture) <br />C405 10 Cooler and Freezer FOr lighting in waik-in coolers and freezers, and refrigerated <br />C405 11 lighting warehouse coolers and freezers, prpvide rated lamp efficacy (En <br />lumens per watt) in fixture schedule <br />Lighting Power Calculation - Indicate compliance path taken <br />Complete required compliance forms — proposed wattage per <br />xea C405.5 2 Building Area Method buifding area does not exceed maximum allowed wattage per <br />building area. Identify locations of building areas on plans <br />Complete required cornpliance forms — total proposed wattage <br />Yes C405 5.2 Space-By-Space does no: exceed maximum allowed wattage Identify locations <br />Method of space types on plans, including retail display areas as <br />applicable <br />EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6 <br />Provide f:xture schedule with fixture types, lamps, ba!lasts, and <br />rated watts per fixture <br />Total connected -----_ ____ _.__.__... _. _ _ __ <br />C405,6.2 exte�ior lighting Identify extenor applications eligible for iighting power <br />power exemption on plans and in compliance fo�ms <br />__._ _ _ _.__ _ � _� � __... _ .. <br />Indicate that exempt exterior lighting is controlled independently <br />hom non-exempt exterior lighting <br />Tab{e Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ <br />C405.6.2(1) <br />Exterior building For buiiding grounds fixtures rated at greater than 100 watts, <br />C405,6.1 grounds lighting Provide rated lamp efficacy (in lumens per watt) in fixture <br />schedule <br />Exterior lighting Complete required compliance fo�m — proposed wattage for <br />C405.62 power calculations exterior lighting plus base site ailowed does not exceed <br />maximum allowed <br />MOTORS & TRANSFORMERS (Sectians C405.8, C405.9) <br />C405 8 Electric Motors For motors not part of an HVAC system, provide electric motor <br />schedule on electrical plans with hp, rpm, and rated efficiency <br />C405 9 Transformers Provide distribution transformer schedule on electrical pians <br />with transformer size and efficiency <br />If "no" is selected fc�r any questian, provide expEanatian: <br />� <br />