Laserfiche WebLink
(P) MECHANICAL <br />BOND FR( <br />ANTENN <br />(E) AGB MOUNTE <br />CHANICALCONNECTION <br />FROM (P) RRH 8 ANTENNA TO (E) AGB <br />OUNTEONEAR ANTENNAS <br />SYMBOL LEGEND: <br />MGB <br />� <br />� <br />MASTER GROUND BAR 1/4'k4"�4" COPPER <br />ACCESSORY GROUND BAR 1/4"xb"z12" OR <br />1/4'kb"x20" COPPER <br />EXPOSED WIRING <br />- — — — - UNDERGROUND WIRING <br />� CADWELD <br />e MECHANICALCONNECTION <br />O Si8'X8' COPPER CLAD STEEL GROUND ROD <br />O INSPECTION PORT <br />_ _ � _ _ EXOTHERMIC (CADWELD) BELOW GROUND <br />GROUNDING NOTES: <br />1. GROUNDING SHALL COMPLY WITH LA7EST EDITION OP THE NATIONAL ELECTRICAL CODE. <br />2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS S". <br />3. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br />4. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINTAT THEIR MATING <br />SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. USE PENETROX <br />OR EOUIVALENT ANTIOXIDANT GREASE. <br />5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION TVPE STACKED <br />CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES <br />OF THE GROUND BAR WILL BE PERMITTED. <br />6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S <br />SPECIFlE� VALUES. <br />7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BV ATLEAST 6". <br />B. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A <br />RESISTANCE OF 5 OHMS TO EARTH. <br />9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL OBJECTS OR <br />SUPPORTS; TOPRECLUDEESTABLISHINGA"CHOKE"POINT. <br />10. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br />11. GROUND RING BURIAL DEPTH SHALL BE 30". <br />12. A CERTIFIED CONTRACTOR WILL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE <br />GROUNDING SYSTEM USING A MEGGER OR E�UIVALENT. THE ACCEPTABLE RESISTANCE <br />MEASURED FOR THE GROUNDING SYSTEM WILL NOT EXCEED 5 OHMS RESISTANCE THREE <br />DISTANCES SHALL BE USED: 1 AT 100 FEET, t AT 70 FEET, AND 1 AT 35 FEET. THESE <br />DISTANCES ARE SUBJECT TO A SITE BY SITE BASIS. T-MOBILE-VJrS SHALL 8E GIVEN 24 <br />HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND TESTING WILL BE AT THE <br />EXPENSEOFTHE CONTRACTOR. <br />(E) AGB MOUNTED NEAR P <br />1 ELECTRICAL GROUNDING PLAN <br />E-� 22x34 SCALE: 12" = 1' <br />11x17 SCALE�, 1/4" = i' <br />BOND FROM (P) RI <br />ANTENNA TO (E) <br />(P) MECHANICAL Ci <br />Spri nt' <br />=PROJECT INFORMATION: <br />DOWNTOWN EVERETT <br />SE03XC527 <br />1602 HEWITT AVE <br />EVERETT, WA 98201 <br />-155UED FOR: <br />BUILDING PERMIT <br />=REVISION HISTORY: <br />MO. DATE: DESCRIPf10N: CHK. <br />er: <br />Q127/2014 SHEET A-0 ADDED BJT <br />Q1/10Y2014 ISSUED DESIGN REVIEW BJT <br />=PLANS PREPARED BY: <br />B. J. THOMAS, P.E. <br />7607 80TH AVE NE <br />MARYSVILLE, WA 98270 <br />206-851-1106 <br />-DRAWN BY: CHK. BY: <br />JL BJ <br />=LICENSURE: <br />� <br />� �,�,.�� �,;: �i2�14 <br />� � /f i � ��', ! \� . <br />f'[.-¢:�g � <br />=EQUIPMENT: <br />INSTALL (3) NEW ANTENNAS 8(3) NEVJ RRH UNITS. <br />=DAAWING INFORMATION: <br />�O NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br />ALL DIMENSIONS AND ADVISE CONSULTANTS OFANY <br />ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS <br />DRAWING ARE SUPERSEDED BY THE LP,TEST REVISION. <br />THE INFORMATION CONTAINED IN THIS SET OF <br />DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR <br />DISCLOSURE OTHER THAN WHICH IS RELP.TED TO NAMED <br />CLIENT IS STRICTLY PROHIBITED. <br />=DRAWING TITLE: <br />ELECTRICAL <br />GROUNDING PLAN <br />E-1 <br />