My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1604 HEWITT AVE SPRINT 2018-10-18
>
Address Records
>
HEWITT AVE
>
1604
>
SPRINT
>
1604 HEWITT AVE SPRINT 2018-10-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2018 9:44:48 AM
Creation date
12/6/2016 9:05:40 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1604
Tenant Name
SPRINT
Notes
ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(P) MECHANICAL <br />BOND FR( <br />ANTENN <br />(E) AGB MOUNTE <br />CHANICALCONNECTION <br />FROM (P) RRH 8 ANTENNA TO (E) AGB <br />OUNTEONEAR ANTENNAS <br />SYMBOL LEGEND: <br />MGB <br />� <br />� <br />MASTER GROUND BAR 1/4'k4"�4" COPPER <br />ACCESSORY GROUND BAR 1/4"xb"z12" OR <br />1/4'kb"x20" COPPER <br />EXPOSED WIRING <br />- — — — - UNDERGROUND WIRING <br />� CADWELD <br />e MECHANICALCONNECTION <br />O Si8'X8' COPPER CLAD STEEL GROUND ROD <br />O INSPECTION PORT <br />_ _ � _ _ EXOTHERMIC (CADWELD) BELOW GROUND <br />GROUNDING NOTES: <br />1. GROUNDING SHALL COMPLY WITH LA7EST EDITION OP THE NATIONAL ELECTRICAL CODE. <br />2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS S". <br />3. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br />4. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINTAT THEIR MATING <br />SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. USE PENETROX <br />OR EOUIVALENT ANTIOXIDANT GREASE. <br />5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION TVPE STACKED <br />CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES <br />OF THE GROUND BAR WILL BE PERMITTED. <br />6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S <br />SPECIFlE� VALUES. <br />7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BV ATLEAST 6". <br />B. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A <br />RESISTANCE OF 5 OHMS TO EARTH. <br />9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL OBJECTS OR <br />SUPPORTS; TOPRECLUDEESTABLISHINGA"CHOKE"POINT. <br />10. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br />11. GROUND RING BURIAL DEPTH SHALL BE 30". <br />12. A CERTIFIED CONTRACTOR WILL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE <br />GROUNDING SYSTEM USING A MEGGER OR E�UIVALENT. THE ACCEPTABLE RESISTANCE <br />MEASURED FOR THE GROUNDING SYSTEM WILL NOT EXCEED 5 OHMS RESISTANCE THREE <br />DISTANCES SHALL BE USED: 1 AT 100 FEET, t AT 70 FEET, AND 1 AT 35 FEET. THESE <br />DISTANCES ARE SUBJECT TO A SITE BY SITE BASIS. T-MOBILE-VJrS SHALL 8E GIVEN 24 <br />HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND TESTING WILL BE AT THE <br />EXPENSEOFTHE CONTRACTOR. <br />(E) AGB MOUNTED NEAR P <br />1 ELECTRICAL GROUNDING PLAN <br />E-� 22x34 SCALE: 12" = 1' <br />11x17 SCALE�, 1/4" = i' <br />BOND FROM (P) RI <br />ANTENNA TO (E) <br />(P) MECHANICAL Ci <br />Spri nt' <br />=PROJECT INFORMATION: <br />DOWNTOWN EVERETT <br />SE03XC527 <br />1602 HEWITT AVE <br />EVERETT, WA 98201 <br />-155UED FOR: <br />BUILDING PERMIT <br />=REVISION HISTORY: <br />MO. DATE: DESCRIPf10N: CHK. <br />er: <br />Q127/2014 SHEET A-0 ADDED BJT <br />Q1/10Y2014 ISSUED DESIGN REVIEW BJT <br />=PLANS PREPARED BY: <br />B. J. THOMAS, P.E. <br />7607 80TH AVE NE <br />MARYSVILLE, WA 98270 <br />206-851-1106 <br />-DRAWN BY: CHK. BY: <br />JL BJ <br />=LICENSURE: <br />� <br />� �,�,.�� �,;: �i2�14 <br />� � /f i � ��', ! \� . <br />f'[.-¢:�g � <br />=EQUIPMENT: <br />INSTALL (3) NEW ANTENNAS 8(3) NEVJ RRH UNITS. <br />=DAAWING INFORMATION: <br />�O NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br />ALL DIMENSIONS AND ADVISE CONSULTANTS OFANY <br />ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS <br />DRAWING ARE SUPERSEDED BY THE LP,TEST REVISION. <br />THE INFORMATION CONTAINED IN THIS SET OF <br />DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR <br />DISCLOSURE OTHER THAN WHICH IS RELP.TED TO NAMED <br />CLIENT IS STRICTLY PROHIBITED. <br />=DRAWING TITLE: <br />ELECTRICAL <br />GROUNDING PLAN <br />E-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.