My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3209 HOYT AVE ROYALE CONDO 2017-01-13
>
Address Records
>
HOYT AVE
>
3209
>
ROYALE CONDO
>
3209 HOYT AVE ROYALE CONDO 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 7:06:01 PM
Creation date
12/6/2016 11:39:51 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3209
Tenant Name
ROYALE CONDO
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING ENCLOSURE SUBMITTAL CHECKLIST <br />FOR NEW OR TENANT IMPROVEMENTS TO MIXED-USE, MULTI-FAMILY OR TOWNHOUSE BUILDINGS <br />EXEMPT BU/LD/NGS: Hotels, motels, dormitories, care facilities, floating homes, mixed-use buildings <br />with maximum of two residential attached dwelling units or less, duplexes, and townhouses (as defined by <br />the IRC) where each unit is on a single platted lot (approved and recorded zero lot line subdivisions). <br />PERMIT AND CERTIFICATE OF OCCUPANCY SUBMITTAL REG�UIREMENTS <br />1. A letter from the applicant certifying that the cost of the construction work on the <br />building enclosure is equal to or less than 5% of the assessed building value*, in <br />addition to the building permit application and two sets of construction plans; or, <br />2. A certified recorded copy of the "Sale Prohibition CovenanY' per RCW 64.55 in addition <br />to the building permit application and two sets of construction plans; or, <br />3. Two complete sets of construction plans (per the building permit application submittal <br />for `New Commercial and Multi-Family', `Tenant Improvement', or `Residential' which <br />meet WA State RCW 64.55 requirements for building enclosure certifications; <br />Maximum size of plan sets: 42" long, 30" wide (bound edge), 5/8" thick. All pages in a <br />plan set shall be uniformly sized <br />4. Completed Permit Application; <br />5. Plan check fee as applicable; and, <br />6. All documents must be clearly legible for microfilming <br />NOTE- Applications are accepted between the hours of 8:U0 AM and 4:00 PM only. <br />"Internet reference for assessed building value, subject to change and verification of single building <br />value: http://web5.co.snohomish.wa.us/propsvs/Asr-Tr-Propinq/Prpinq01-Entrv.asp <br />The City of Everett will not review or approve plans or inspect the work required by RCW 64.55 but wfll collect <br />the required submittals for RCW 64.55 as noted vn this checklist. <br />I. REQUIRED PRIOR TO ISSUING A BUILDING PERMIT <br />A. The building enclosure design documents submitted for permit should include details and <br />specifications to protect the building or its components from water or moisture intrusion, <br />including details of flashing, intersections at roof, eaves or parapets, means of drainage, <br />water-resistive membrane, and details around openings. These documents should be <br />submitted prior to the start of new construction or rehabilitative construction. <br />B. Building enclosure design documents must contain a stamped statement by the Washington <br />State licensed architect or engineer in substantially the following form: "The undersigned has <br />provided building enclosure documents that in my professional judgment are appropriate to <br />satisfy the requirements of RCW 64.55.005 through 64.55.090." <br />REQUIRED PRIOR TO SCHEDULING FINAL INSPECTION <br />A. A qualified inspector (a special inspector retained by the o�vner at their cost) shall prepare and <br />submit a signed letter certifying to the City of Everett Building Department Building Official that <br />the building enclosure has been inspected during the course of construction or rehabilitative <br />construction and that it has been constructed in substantial compliance with the submitted <br />building enclosure design documents. <br />APPLICABLE CODES AND REFERENCES <br />• Chapter 64.55 RCW Construction Defect Disputes-Multiunit Residential Buildings, effective date <br />8/01/2005. Internet reference: http://apps.leQ.wa.aov/RCW/default.aspx?cite=64.55 <br />• Chapter 64.34 RCW Washington Condominium Act <br />chklst-com (rev 8/5/09) <br />CITY OF EVERETT BUILDING DEPARTMENT 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br />www. everettwa. org <br />
The URL can be used to link to this page
Your browser does not support the video tag.