Laserfiche WebLink
Geotechnical E�lgineering Letter <br />Alhussaini Slope Stabilization and Retaining Walls <br />Everett, Washington <br />NGA File No. 867612 <br />December 10, 2012 <br />Page 11 <br />The total height of the planiied walls is expected to be up to 6.5 feet, including a ininimum <br />reconliilended eilibedment of 1.5 feet into competent soils. We have provided w111 designs for up <br />to an 8-foot higl� i-etainin� wall with Keystone block facing. We recomn�end that walls greater <br />Chan four Ieet in total height (exposcd l�cibht plus wall embedment) be constructcd utilizin� <br />geogrid reinForced backfill. Walls less lhan [our i�ct in total height can be constructed without <br />beogrid reinforced backtilL The wall detail and design parameters along with consti-uctio�l notes <br />for walls greater than or enual to four feet in total height are shown on Figure 8. We have <br />assumed that the i-etained flll zones will consist of gra�iular material compacted to structural flll <br />specifications. The fill should be placed level behind tlle walls and exte�id back into the slope. <br />The draii�age system, as indicated on the detail, should be installed along the base of the blocks <br />and behind the Keystone block facing. <br />The block facing should consist of Keystone Standard 21.5-inch Block facing. The block i'acing <br />sllould be pLaced on a mi��imuni of 4-inch thick crushed rock leveling pads placed over competent <br />native soils, or stiuctural t111 material }�repared under the supervision of NGA. The subgrade <br />should be ii-ee of any undocuuzeuted fill or topsoil and be comp�etcd to a non-yielding condition <br />before placing the blocks. Where loosc undocumcnted till soils arc encountered at the planned <br />relaining wall subgrade elevation, the subgradc should be over-excavaled by a minimuin of one <br />foot and replaced with 1-1/4-inch crushed rock compacted to structural fill specifications. We <br />also recommend that aLl undocumented lill found within the planned reinforced till areas be <br />overcxcavated prior to construction of the walls. The wall and reinforced fill areas should also be <br />graded to level bencl�es prioi- to wall and reinforced fill conslruction. Since the walls will be <br />terraced, we recomme�ld that the lowest block cetainiug wall be constructed to completion prior to <br />beginning construction of the upper wall. All tiers should be separated by a minimun� horizontal <br />distance of 20 feet. <br />A drainage blanket of 12 inches of fi-ee-draining crushed rock should be placed between the <br />blocks and tLle retained fill zone. The block cavities should also be tilled with the crushed rock. <br />A rigid, perforated drainpipe embedded iu a niinimum of 1-foot of pea gcavel �ind wrapped in � <br />NELSON GEOTECHNICAL ASSOCIATES, INC. <br />