My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 112TH ST SE 30 10 WEIGHT LOSS FOR LIFE 2018-09-19
>
Address Records
>
112TH ST SE
>
1327
>
30 10 WEIGHT LOSS FOR LIFE
>
1327 112TH ST SE 30 10 WEIGHT LOSS FOR LIFE 2018-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2018 1:44:10 PM
Creation date
12/14/2016 2:19:34 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
1327
Tenant Name
30 10 WEIGHT LOSS FOR LIFE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r , <br />PUBL/C L�t/OR/C5' <br />err <br />December 13, 2013 <br />Ms. Kendahl Fulkerson <br />Conneli Design <br />22002 64th Ave W, Suite 2C <br />Mountlake Terrace, WA 98043 <br />Project: <br />]ob Address: <br />Plan Review: <br />Tenant Improvement for 30/10 Weight Loss <br />1327 112th St SE Ste B <br />B1312-005 <br />Dear Ms. Fulkerson, <br />. ` ;.�� ' �-�-I!�4i�i <br />�2�, 3 J, � <br />In response to your application for a construction permit and our conversations this week, your <br />plans have been examined and you are advised that revisions may be required. Plan review will <br />resume when the requested information is submitted. Please review and respond to the <br />comments below. All required submittals must be of sufficient detail and information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two sets of construction documents which reflect <br />the corrections requested. Unaffected sheets do not have to be resubmitted. E- <br />mailed sheet revisions are acceptable, if you would specify the drawing size. <br />General <br />1. Please include the mechanical and fire codes in project data on Sheet T1,0. <br />Occupancy <br />1. Please revise the occupant load and occupancy throughout the set per your recent e- <br />mail regarding business use, per IBC table 1004.1.1. <br />Energy <br />1. Please show or scope lighting reduction controls on the drawings, per WSEC C405.2.1.2. <br />2. Please show or scope additional lighting controls on the drawings, per WSEC C405.2.2. <br />Deferred Permits Requiring Drawings <br />1. Mechanical, sign, and suppression permits should be submitted as separate permit <br />applications. <br />a. The toilet room exhaust is required to be minimum either 50 CFM continuous, or <br />70 CFM intermittent, per IMC table 403.3. <br />Applicable codes include the 2012 International Building Code (IBC), the 2012 International Fire <br />Code (IFC), the 2012 International Mechanical Code (IMC), the 2012 Washington State Energy <br />Code (WSEC), as amended by the by the State of Washington and adopted by the City of <br />Everett. The current IBC referenced standard for accessible design is the Accessible and Usable <br />Buildings and Facilities A117.1-2009 (ICC/ANSI). Federa/ADA regulations and standards may <br />be more restrictive. <br />
The URL can be used to link to this page
Your browser does not support the video tag.