My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1924 113TH PL SE 2017-01-13
>
Address Records
>
113TH PL SE
>
1924
>
1924 113TH PL SE 2017-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2017 9:53:30 PM
Creation date
12/22/2016 1:44:21 PM
Metadata
Fields
Template:
Address Document
Street Name
113TH PL SE
Street Number
1924
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� ; <br />�;,, <br />�;:;�<�- <br />��" �;:;; <br />_;,;:;, <br />i.. <br />June 3, 2015 <br />ES-3588.01 <br />� .� zS"ol pn�� <br />� ����� - = <br />a ��. <br />Earth Solutions NW ��c <br />� C���r�tec:i���ical EnF;i;��-eri;,;, <br />° C.t;n�,frucrir,n ,`1�,nito-fns, <br />m [ :��irnr'���F n�: l �; i�.,it.:.,:.. <br />Polygon NW <br />PO Box 1349 <br />Bellevue, Washington 98009 <br />Attention: Mr. Eddy Stevens <br />Subject: Final Report <br />Building 5, Lots 5.1 thru 5.7 <br />Building 6, Lots 6.1 thru 6.4 <br />Buiiding 20, Lots 20.1 thru 20.8 <br />Construction Monitoring and Consuiting Services <br />Silver Lake Center <br />Building 5- 1904 thru 1928 — 113th P1ace Southeast <br />Building 6- 1919 thru 1929 — 113t" Place Southeast <br />Building 20 - 11002 thru 11016 — 20t" Drive Southeast <br />Everett, Washington <br />Dear Mr. Stevens: <br />1n accordance with your request, Earth Solutions NW, LLC (ESNW) provided construction <br />monitoring and consulting services at the subject site. Our services inc{uded providing onsite <br />observatians and festing on a part-time from January 26 io A�ril 3, 201 �. Our representatives <br />made 11 site visits to observe building foundation subgrade and test building slab backfill. <br />Our representative observed building foundation subgrade to be dense and suitable for support <br />of the proposed structures. <br />Our representative conducted 50 field density tests in accordance with ASTM Test Designation <br />D2922 (Nuclear Gauge Method). Three representative soil samples were returned to our <br />laboratory for analysis of the maximum dry density and optimum moisture content in <br />accordance with ASTM D1557-02 (Modified Proctor). Density test results indicate adequate <br />compaction of at least 95 percent at the tested locations of the building slab backfill. <br />Based on our observations and testing, the earthwork construction was accomplished in <br />accordance with the project plans and our geotechnical recommendations. <br />I�G'i - I jf�i:'l i'I:1Cf ��.'.., �UI!?- t'tl C��i[: t., :�e;i �h . 'S °+ f''L`>! +�1).-=ii;ti • �;\X 111�) ':'I�i-d,'' I ; <br />�� <br />:i��=i�;, <br />
The URL can be used to link to this page
Your browser does not support the video tag.